AI-Assisted Optical Diagnosis (CADx) for Diminutive Colorectal Polyps (CADxGIG)
Prospective Multicenter Validation of an Artificial Intelligence-Assisted Optical Diagnosis Strategy (CADx) for the Real-Time Characterization of Diminutive Colorectal Polyps: A STARD-Compliant Diagnostic Accuracy Study
研究概览
详细说明
Colonoscopy with polypectomy is the cornerstone of colorectal cancer (CRC) screening and prevention. The majority of polyps detected during colonoscopy are diminutive (≤5 mm) and carry a very low risk of harbouring advanced pathology. In Canada, over 1.9 million colonoscopies are performed annually, and sending all diminutive polyps for histopathological examination (at a cost of approximately $150-$300 CAD per specimen) generates a substantial economic burden with limited benefit for cancer prevention.
Two international guideline frameworks define the performance thresholds required for clinical adoption of optical diagnosis strategies for diminutive colorectal polyps. The ASGE PIVI initiative (2011) established (1) ≥90% negative predictive value (NPV) for adenomatous histology among diminutive rectosigmoid polyps diagnosed with high confidence ("diagnose-and-leave" threshold), and (2) ≥90% agreement between optical-diagnosis-based and pathology-based post-polypectomy surveillance intervals ("resect-and-discard" threshold). The more recent ESGE SODA position statement (2022) adopted sensitivity and specificity as the foundational, prevalence-independent performance measures for high-confidence real-time characterization of colorectal neoplasia, applicable across all colonic locations: sensitivity ≥90% and specificity ≥80% for the rectosigmoid subset, and sensitivity ≥80% and specificity ≥80% across all diminutive colorectal polyps regardless of location.
The investigators' research group has previously conducted several single-centre studies evaluating early-generation, Health Canada-approved computer-aided diagnosis (CADx) systems in routine clinical practice, generating one of the largest real-world CADx implementation datasets in the literature (868 patients, 1,660 diminutive polyps). These studies consistently demonstrated suboptimal overall diagnostic accuracy (62.7%-66.4%), attributable to restricted training datasets and limited polyp-classification capabilities in early-generation devices. GI Genius (Medtronic), the newer-generation, Health Canada-approved CADx module evaluated in this study, was trained on a larger and more diverse dataset of annotated endoscopic images and videos. Whether this translates into measurable gains in diagnostic performance sufficient to meet international competence thresholds has not been established in an independent, prospective, multicentre study, and is the question this study addresses.
This is a prospective, three-centre diagnostic accuracy study conducted in accordance with the Standards for Reporting Diagnostic Accuracy Studies (STARD 2015). It is a single-arm study validating a CADx-assisted optical-diagnosis strategy - rather than autonomous or standalone CADx performance - in which the endoscopist's final CADx-assisted optical diagnosis constitutes the primary index test. For each diminutive polyp (≤5 mm) identified during an already-scheduled elective colonoscopy, the following sequential steps are performed: (1) the endoscopist records a CADx-unassisted optical diagnosis (adenoma, hyperplastic polyp, or other) and confidence level (high or low), which is electronically locked before any device output is viewed; (2) the CADx module is activated and displays its own characterization of the polyp; (3) the endoscopist records a final CADx-assisted optical diagnosis and confidence level, remaining free to agree or disagree with the device; (4) a research assistant documents polyp size, morphology (Paris classification), and colonic location; and (5) the polyp is resected per standard technique and sent for histopathological examination, which serves as the reference standard. This sequential-locking design - recording and locking the unassisted diagnosis before CADx activation - is the study's key strategy for minimizing contamination bias between the two diagnostic strategies, and allows each polyp to generate two paired diagnostic data points (CADx-unassisted and CADx-assisted) compared against a single histopathological reference standard.
The study will enroll consecutive patients aged 45-80 years undergoing elective colonoscopy (screening, surveillance, or diagnostic indication) at three Canadian academic centres: Santé Québec - CHUM (Montreal), the McGill University Health Centre (MUHC/CUSM, Montreal), and St. Paul's Hospital (Vancouver), who provide written informed consent before the colonoscopy and before sedation.
Inclusion criteria: signed informed consent obtained before the colonoscopy and before sedation; age 45-80 years; indication for elective colonoscopy (screening, surveillance, or diagnostic); and at least one diminutive polyp (≤5 mm) detected during the procedure, which is required for inclusion in the analytic cohort (consented patients in whom no eligible polyp is detected are documented as screen failures and do not contribute to the primary analysis).
Exclusion criteria: known inflammatory bowel disease; active colitis; coagulopathy or thrombocytopenia (INR ≥1.5 or platelets <50×10⁹/L); familial polyposis syndrome; American Society of Anesthesiologists (ASA) classification >III; emergency colonoscopy; and inadequate bowel preparation (Boston Bowel Preparation Scale <6).
All staff gastroenterologists and gastroenterology trainees performing elective colonoscopies at participating centres are eligible to participate as endoscopists, with no additional optical-diagnosis training provided, reflecting real-world implementation conditions.
The primary objective is to determine the sensitivity and specificity of CADx-assisted optical diagnosis for adenomatous histology among all diminutive colorectal polyps, benchmarked against the ESGE SODA competence thresholds (sensitivity ≥80%, specificity ≥80%), using histopathology as the reference standard. Secondary objectives include: the NPV of CADx-assisted diagnosis among high-confidence diminutive rectosigmoid polyps (ASGE PIVI threshold ≥90%); agreement between CADx-assisted and pathology-based surveillance interval recommendations (ASGE PIVI threshold ≥90%); sensitivity and specificity for the rectosigmoid subset (ESGE SODA threshold: sensitivity ≥90%, specificity ≥80%); a paired comparison of CADx-assisted versus CADx-unassisted diagnostic performance; diagnostic confidence calibration; and the proportion of CADx-assisted diagnoses made with high confidence. Prespecified exploratory subgroup analyses will evaluate diagnostic performance by polyp size (≤3 mm vs. 4-5 mm), morphology, colonic location, endoscopist experience level, patient biological sex, and study centre. A tertiary/exploratory objective is an integrated health economic evaluation - combining a decision tree and a state-transition Markov model, from both health-system and societal perspectives - assessing the cost-effectiveness of a possible future CADx-assisted "resect-and-discard"/"diagnose-and-leave" strategy compared with universal histopathological examination, with results reported per the CHEERS 2022 checklist.
A minimum of 826 patients is required to evaluate both co-primary outcomes (sensitivity and specificity) with an overall power of 80%, accounting for intra-patient clustering of polyps (design effect 1.3, based on an average of 1.91 diminutive polyps per patient and an intraclass correlation of 0.3). A recruitment target of 840 patients (approximately 1,605 diminutive polyps), enrolled evenly across the three centres (280 per centre) over an expected 24-month recruitment period, has been set to exceed this minimum. Sensitivity and specificity will be estimated using generalized linear mixed models with a logit link and a random effect for patient, to account for clustering of polyps within patients; each one-sided hypothesis test (H₀: sensitivity or specificity ≤80%) will be conducted at α=0.025, with study success requiring rejection of both null hypotheses. Prespecified sensitivity analyses include a per-protocol analysis, a high-confidence-only analysis aligned with formal ESGE SODA competence assessment, a reclassification of serrated lesions as neoplastic, models incorporating a random effect for endoscopist, and a temporal analysis for learning-curve or fatigue effects. No interim analyses are planned; all analyses will be conducted after complete enrolment.
There is no increased risk to participants beyond the standard risks of colonoscopy, since all polyps are resected according to usual clinical practice regardless of study participation, and no additional procedures (blood sampling, imaging, additional sedation, or follow-up visits) are performed for research purposes. This is an investigator-initiated study (Sponsor-Investigator: Dr. Daniel von Renteln, CHUM/CRCHUM); Medtronic Canada provides the GI Genius CADx equipment on loan for the study period, together with related installation and technical support only, and has no role in study design, recruitment, data collection, endpoint adjudication, statistical analysis, interpretation, or publication decisions.
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:Daniel von Renteln, Doctor of Medicine (MD), Gastr
- 电话号码:30912 514-890-8000
- 邮箱:daniel.von.renteln.med@ssss.gouv.qc.ca
研究联系人备份
- 姓名:Samira Hanin, Research Coordinator
- 电话号码:30916 514-890-8000
- 邮箱:samira.hanin.chum@ssss.gouv.qc.ca
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Signed informed consent, obtained before the colonoscopy and before sedation
- Age 45-80 years
- Indication for elective colonoscopy (screening, surveillance, or diagnostic)
- At least one diminutive polyp (≤5 mm) detected during the procedure (required for inclusion in the analytic cohort; consented patients without an eligible polyp are documented as screen failures)
Exclusion Criteria:
- Known inflammatory bowel disease
- Active colitis
- Coagulopathy or thrombocytopenia (INR ≥1.5 or platelets <50×10⁹/L)
- Familial polyposis syndrome
- American Society of Anesthesiologists classification >III
- Emergency colonoscopy
- Inadequate bowel preparation (Boston Bowel Preparation Scale <6)
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
Diminutive Colorectal Polyps - CADx-Assisted Optical Diagnosis
Consecutive patients aged 45-80 undergoing elective colonoscopy (screening, surveillance, or diagnostic) at CHUM, CUSM, and St. Paul's Hospital who provide written informed consent before the colonoscopy and before sedation, and in whom at least one diminutive polyp (≤5 mm) is detected during the procedure.
For each diminutive polyp, the endoscopist first records a CADx-unassisted optical diagnosis and confidence level (electronically locked before device activation), then activates the GI Genius CADx module, and records a final CADx-assisted optical diagnosis and confidence level after viewing the device-provided characterization.
All polyps are resected and sent for histopathological examination, which serves as the reference standard.
|
Computer-aided diagnosis (CADx) device recently approved by Health Canada, used to provide real-time optical characterization of diminutive colorectal polyps (≤5 mm) during colonoscopy.
For each diminutive polyp detected, the endoscopist first records a CADx-unassisted optical diagnosis (electronically locked before device activation), then activates the GI Genius CADx module, which displays a device-provided characterization.
The endoscopist then records a final CADx-assisted optical diagnosis, which may agree or disagree with the device output.
The study evaluates the CADx-assisted optical-diagnosis strategy (endoscopist + device combined) rather than autonomous or standalone CADx performance.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Sensitivity of CADx-assisted optical diagnosis for adenomatous histology
大体时间:Within 14 to 45 days after polypectomy (colorectal polyp resection during the index colonoscopy), once histopathology results are available
|
Number of correct adenomatous optical diagnoses divided by the number of histologically confirmed adenomas, among all diminutive (≤5 mm) colorectal polyps, benchmarked against the ESGE SODA threshold (≥80%)
|
Within 14 to 45 days after polypectomy (colorectal polyp resection during the index colonoscopy), once histopathology results are available
|
|
Specificity of CADx-assisted optical diagnosis for adenomatous histology
大体时间:Within 14 to 45 days after polypectomy (colorectal polyp resection during the index colonoscopy), once histopathology results are available
|
Number of correct non-adenomatous optical diagnoses divided by the number of histologically confirmed non-adenomas, among all diminutive (≤5 mm) colorectal polyps, benchmarked against the ESGE SODA threshold (≥80%)
|
Within 14 to 45 days after polypectomy (colorectal polyp resection during the index colonoscopy), once histopathology results are available
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
NPV of CADx-assisted optical diagnosis for adenomatous histology (rectosigmoid, high confidence)
大体时间:Within 14 to 45 days after polypectomy (colorectal polyp resection during the index colonoscopy), once histopathology results are available
|
Benchmark : ASGE PIVI ≥90%.
|
Within 14 to 45 days after polypectomy (colorectal polyp resection during the index colonoscopy), once histopathology results are available
|
|
Surveillance interval agreement
大体时间:Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
Proportion of patients with agreement between CADx-assisted and pathology-based surveillance interval recommendations (ASGE PIVI ≥90%).
|
Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
|
Sensitivity and specificity, rectosigmoid subset
大体时间:Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
ESGE SODA Recommendation 1 (sensitivity ≥90%, specificity ≥80%)
|
Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
|
CADx-assisted vs. CADx-unassisted diagnostic performance
大体时间:Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
Paired within-polyp comparison of adenoma sensitivity/specificity
|
Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
|
High-confidence prediction rate
大体时间:Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
Proportion of CADx-assisted diagnoses made with high confidence
|
Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
|
Confidence calibration
大体时间:Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
Adenoma sensitivity/specificity among high- vs. low-confidence diagnoses, for both CADx-assisted and unassisted strategies
|
Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
其他结果措施
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Health economic outcome
大体时间:Outcomes assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
Incremental cost-effectiveness of the CADx-assisted strategy vs. universal histopathological examination
|
Outcomes assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
|
Subgroup diagnostic performance
大体时间:Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
By polyp size (≤3 mm vs. 4-5 mm), morphology (Paris classification), colonic location, endoscopist experience, patient sex, and centre
|
Outcome assessed throughout the 24-month recruitment period, with total study duration of 36 months
|
合作者和调查者
出版物和有用的链接
一般刊物
- Hassan C, Spadaccini M, Iannone A, Maselli R, Jovani M, Chandrasekar VT, Antonelli G, Yu H, Areia M, Dinis-Ribeiro M, Bhandari P, Sharma P, Rex DK, Rosch T, Wallace M, Repici A. Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis. Gastrointest Endosc. 2021 Jan;93(1):77-85.e6. doi: 10.1016/j.gie.2020.06.059. Epub 2020 Jun 26.
- Byrne MF, Chapados N, Soudan F, Oertel C, Linares Perez M, Kelly R, Iqbal N, Chandelier F, Rex DK. Real-time differentiation of adenomatous and hyperplastic diminutive colorectal polyps during analysis of unaltered videos of standard colonoscopy using a deep learning model. Gut. 2019 Jan;68(1):94-100. doi: 10.1136/gutjnl-2017-314547. Epub 2017 Oct 24.
- Rex DK, Kahi C, O'Brien M, Levin TR, Pohl H, Rastogi A, Burgart L, Imperiale T, Ladabaum U, Cohen J, Lieberman DA. The American Society for Gastrointestinal Endoscopy PIVI (Preservation and Incorporation of Valuable Endoscopic Innovations) on real-time endoscopic assessment of the histology of diminutive colorectal polyps. Gastrointest Endosc. 2011 Mar;73(3):419-22. doi: 10.1016/j.gie.2011.01.023.
- Hassan C, Pickhardt PJ, Rex DK. A resect and discard strategy would improve cost-effectiveness of colorectal cancer screening. Clin Gastroenterol Hepatol. 2010 Oct;8(10):865-9, 869.e1-3. doi: 10.1016/j.cgh.2010.05.018. Epub 2010 Jun 1.
- Mori Y, Kudo SE, Misawa M, Saito Y, Ikematsu H, Hotta K, Ohtsuka K, Urushibara F, Kataoka S, Ogawa Y, Maeda Y, Takeda K, Nakamura H, Ichimasa K, Kudo T, Hayashi T, Wakamura K, Ishida F, Inoue H, Itoh H, Oda M, Mori K. Real-Time Use of Artificial Intelligence in Identification of Diminutive Polyps During Colonoscopy: A Prospective Study. Ann Intern Med. 2018 Sep 18;169(6):357-366. doi: 10.7326/M18-0249. Epub 2018 Aug 14.
- Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig L, Lijmer JG, Moher D, Rennie D, de Vet HC, Kressel HY, Rifai N, Golub RM, Altman DG, Hooft L, Korevaar DA, Cohen JF; STARD Group. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. BMJ. 2015 Oct 28;351:h5527. doi: 10.1136/bmj.h5527.
- ASGE Technology Committee; Abu Dayyeh BK, Thosani N, Konda V, Wallace MB, Rex DK, Chauhan SS, Hwang JH, Komanduri S, Manfredi M, Maple JT, Murad FM, Siddiqui UD, Banerjee S. ASGE Technology Committee systematic review and meta-analysis assessing the ASGE PIVI thresholds for adopting real-time endoscopic assessment of the histology of diminutive colorectal polyps. Gastrointest Endosc. 2015 Mar;81(3):502.e1-502.e16. doi: 10.1016/j.gie.2014.12.022. Epub 2015 Jan 16.
- Djinbachian R, Haumesser C, Taghiakbari M, Pohl H, Barkun A, Sidani S, Liu Chen Kiow J, Panzini B, Bouchard S, Deslandres E, Alj A, von Renteln D. Autonomous Artificial Intelligence vs Artificial Intelligence-Assisted Human Optical Diagnosis of Colorectal Polyps: A Randomized Controlled Trial. Gastroenterology. 2024 Jul;167(2):392-399.e2. doi: 10.1053/j.gastro.2024.01.044. Epub 2024 Feb 7.
- Houwen BBSL, Hassan C, Coupe VMH, Greuter MJE, Hazewinkel Y, Vleugels JLA, Antonelli G, Bustamante-Balen M, Coron E, Cortas GA, Dinis-Ribeiro M, Dobru DE, East JE, Iacucci M, Jover R, Kuvaev R, Neumann H, Pellise M, Puig I, Rutter MD, Saunders B, Tate DJ, Mori Y, Longcroft-Wheaton G, Bisschops R, Dekker E. Definition of competence standards for optical diagnosis of diminutive colorectal polyps: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement. Endoscopy. 2022 Jan;54(1):88-99. doi: 10.1055/a-1689-5130. Epub 2021 Dec 6.
- Biffi C, Salvagnini P, Dinh NN, Hassan C, Sharma P; GI Genius CADx Study Group; Cherubini A. A novel AI device for real-time optical characterization of colorectal polyps. NPJ Digit Med. 2022 Jun 30;5(1):84. doi: 10.1038/s41746-022-00633-6.
- Husereau D, Drummond M, Augustovski F, de Bekker-Grob E, Briggs AH, Carswell C, Caulley L, Chaiyakunapruk N, Greenberg D, Loder E, Mauskopf J, Mullins CD, Petrou S, Pwu RF, Staniszewska S; CHEERS 2022 ISPOR Good Research Practices Task Force. Consolidated Health Economic Evaluation Reporting Standards 2022 (CHEERS 2022) statement: updated reporting guidance for health economic evaluations. BMJ. 2022 Jan 11;376:e067975. doi: 10.1136/bmj-2021-067975.
- Dekker E, Houwen BBSL, Puig I, Bustamante-Balen M, Coron E, Dobru DE, Kuvaev R, Neumann H, Johnson G, Pimentel-Nunes P, Sanders DS, Dinis-Ribeiro M, Arvanitakis M, Ponchon T, East JE, Bisschops R. Curriculum for optical diagnosis training in Europe: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement. Endoscopy. 2020 Oct;52(10):899-923. doi: 10.1055/a-1231-5123. Epub 2020 Sep 3.
有用的网址
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他研究编号
- MP-02-2027-13785
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
在美国制造并从美国出口的产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.