此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Agreement Between 5 Different Pulse Oximeters Used Simultaneously During a Six-minute Walk Test

2026年7月30日 更新者:Ligue Pulmonaire Genevoise

Agreement Between 5 Different Pulse Oximeters Used Simultaneously During a Six-minute Walk Test (Concordance Entre Pulse oxymètres Lors d'un Test de Marche standardisé de 6 Minutes)

This study aims to compare the results obtained during a standardised 6-minute walk test with five different pulse oximeters, in adults admitted to an outpatient pulmonary rehabilitation program, to determine the agreement between devices of current use for measuring oxygen saturation (SpO2) and identifying subjects with desaturation during the test.

研究概览

地位

完全的

详细说明

51 patients will be included in this study , corresponding to an inclusion period of approximately 3 months.

Patients are all referred for an outpatient pulmonary rehabilitation program for which one or several six-minute walk test (6MWT) is standard procedure.

After the patient has given his/her consent and signed the consent form, they will be fitted with various pulse oximeter sensors (all CE certified and Bluetooth enabled):

  • An ear sensor connected to the Nonin Wrist OX2 3150 pulse oximeter
  • A flexible digital sensor connected to a Nonin Wrist OX2 3150 pulse oximeter
  • A MightySat Rx digital pulse oximeter
  • A rigid digital sensor connected to the Masimo Rad-G pulse oximeter
  • A Nonin Vantage 9590 digital pulse oximeter from Onyx

The pulse oximeters are placed on the fingers of one hand (chosen according to patient comfort) and a lightweight shoulder strap is used to hold the arm against the abdomen in order to minimise any movement artefacts caused by arm swinging during walking. One of the oximeters is connected to a sensor placed on the earlobe . The last oximeter (Nonin Vantage 9590 from Onyx) is not equipped with Bluetooth transmission and cannot calculate the average or minimum SpO2. However, it is representative of the pulse oximeters commonly acquired and used by patients and caregivers. We will therefore record the results it gives at T0, T6, and at the end of the observation (it will be placed on the free hand).

The patient then receives standardised information about the six-minute walk test procedure (6MWT). The nurse or physiotherapist measures the patient's vital signs at rest: HR, BP, SpO2, dyspnoea on a modified Borg scale.

The 6MWT is then performed for 6 minutes in a marked 30-metre corridor, with standardised information provided every minute until the end of the test, in accordance with international recommendations. The patient is asked to walk at a pace that they think they can maintain for 6 minutes. If they experience excessive dyspnoea, they may sit down and resume the test as soon as they feel able to do so. The test is interrupted if SpO2 falls below 80% (on any of the pulse oximeters). Perceived breathlessness is recorded every minute. SpO2 and HR results are transmitted via Bluetooth to a tablet and can be monitored 'live'.

At the end of the test, the patient sits down and their vital signs are measured for another 2 minutes.

The data obtained during the test is then coded and transferred to an electronic case report form (eCRF) with a numerical code that does not refer to the patient's date of birth or initials.

A list of cases and their codes is kept in a password-protected Excel file, stored by a person outside the study staff.

Inclusion in the protocol takes place at most once per patient.

研究类型

观察性的

注册 (实际的)

56

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Canton of Geneva
      • Meyrin、Canton of Geneva、瑞士、1217
        • Hôpital de La Tour

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

取样方法

非概率样本

研究人群

Patients admitted to an outpatient pulmonary rehabilitation program

描述

Inclusion Criteria:

  • All patients referred to our Cardiorespiratory Unit for a pulmonary rehabilitation programme
  • Aged over 18, no maximum age limit
  • Absence of language barriers or cognitive impairments that would make it impossible to explain the protocol
  • Resting SpO2 > 90%
  • Signing the informed consent form after receiving detailed information about the study.

Exclusion Criteria:

  • Any clinical condition that makes it impossible or compromises the performance of a walking test: unstable heart disease, acute myocarditis and/or pericarditis, acute arrhythmia, severe pulmonary hypertension, deep vein thrombosis, severe asthma, acute orthopaedic or rheumatic condition
  • Unstable clinical condition (patient hospitalised or less than 4 weeks after an exacerbation leading to hospitalisation)
  • Oxygen therapy at rest and/or during walking
  • Uncontrolled arterial hypertension (AHT) at rest
  • Known cardiac rhythm disorder
  • Unexplained chest pain at rest
  • Mechanical interference with the possibility of placing pulse oximeters: skin lesions, bandages, plaster casts, etc.
  • Withdrawal of consent during the study
  • Systemic scleroderma, sclerodactyly, history of any type of vasculitis
  • Symptomatic Raynaud's phenomenon
  • Marked clubbing
  • Known haemoglobinopathy
  • Refusal to remove nail polish

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
Study group
All patients undergo the same simultaneous measurement of oxygen saturation with 5 different devices. No randomisation, no sham device.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Limits of agreement between devices for oxygen saturation (SpO2) at the end of a six-minute walk test.
大体时间:Baseline
An analysis according to the Bland and Altman method comparing devices by pairs allows to determine the bias (mean error) and the limits of agreement for the SpO2 measured at the end of the walk test.
Baseline

次要结果测量

结果测量
措施说明
大体时间
Limits of agreement between devices for heart rate at T0 (start of test), T6 (end of test) and maximal and minimal values
大体时间:Baseline
Same analysis as primary outcome
Baseline
Agreement between devices for identifying subjects who have a significant drop in SpO2 (desaturate) during the six-minute walk test
大体时间:Baseline
Subjects will be identified as desaturating or not according to 5 pre-defined criteria (minimal SpO2 < or = 90%, < or = 88%; mean SpO2 < or = 90%, < or = 88%; presence or absence of a drop in SpO2 > or = 4% between T0 and minimal value recorded)
Baseline

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2025年6月1日

初级完成 (实际的)

2026年3月31日

研究完成 (实际的)

2026年3月31日

研究注册日期

首次提交

2025年9月1日

首先提交符合 QC 标准的

2026年7月30日

首次发布 (实际的)

2026年8月3日

研究记录更新

最后更新发布 (实际的)

2026年8月3日

上次提交的符合 QC 标准的更新

2026年7月30日

最后验证

2026年7月1日

更多信息

与本研究相关的术语

其他研究编号

  • 2024-02489

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅