Non-invasive Optical Low-frequency Oscillation Study of the Prefrontal Cortex Based on fNIRS
2026年8月6日 更新者:Ting Li、Peking Union Medical College
The investigators aimed to investigate the effects of different cognitive load tasks (1-back, 2-back, 3-back) on low-frequency oscillations (LFOs) in the prefrontal cortex of healthy young individuals, analyze the relationship between LFO parameters (power, peak amplitude, peak frequency) and behavioral performance (reaction time, accuracy), and validate the feasibility of using LFOs as a quantitative measure of brain resting-state activity and a sensitive indicator of cognitive load.Low-frequency oscillations (LFO, 0.05-0.15
Hz) are a core feature of cerebral hemodynamics and are closely related to neural activity, blood pressure regulation, and metabolic function.
Existing studies suggest that LFO may be influenced by cognitive load during mental tasks, but the underlying mechanisms remain unclear.
Functional near-infrared spectroscopy (fNIRS), with its advantages of non-invasiveness, portability, and high temporal resolution, enables precise monitoring of hemodynamic parameters in the prefrontal cortex, including changes in oxygenated and deoxygenated hemoglobin concentrations (Δ[oxy-Hb], Δ[deoxy-Hb]).
This study combines the N-back working memory task to investigate how cognitive load modulates LFO, offering a novel approach for assessing brain function.In this study, the investigators used a portable 16-channel continuous-wave functional near-infrared spectroscopy (fNIRS) system to measure dynamic changes in prefrontal cortex (PFC) hemodynamic parameters-Δ[oxy-Hb], Δ[deoxy-Hb], and Δ[tot-Hb]-in 48 healthy participants under varying task loads.
The investigators then analyzed low-frequency oscillations (LFOs) based on the detected hemodynamic parameter fluctuations, following established methodologies from prior research.
Using Welch's method, LFOs were extracted from power spectral density (PSD) of different hemodynamic parameters across three task conditions (1-back, 2-back, and 3-back).
The principle of fNIRS relies on near-infrared light penetrating the skull and brain, being absorbed by chromophores [HbO₂] and [Hb] with distinct absorption spectra.
Assuming constant scattering and applying the modified Beer-Lambert law during calculations, sensitive light intensity detectors can detect concentration changes of these chromophores within the subject's brain tissue.
The experimental setup consisted of a 4.4 cm × 15 cm sensor array distributed across the forehead, a dedicated data acquisition control box with a sampling rate of 3.3 Hz, and a computer for data storage and analysis software.
The current flexible sensor comprises four light sources and ten detectors.
The light sources include three built-in LEDs with peak wavelengths at 735 nm, 805 nm, and 850 nm, while the detectors are designed to image the sub-frontal cortical regions (dorsolateral and ventromedial prefrontal cortices).
The distance between each source and its surrounding detectors is 2.89 cm, enabling hemodynamic measurements at depths of 2-3 cm beneath the scalp, focusing primarily on the cerebral cortex.
Each light source is arranged in an X-shape with four adjacent detectors, where the source is centered and detectors positioned at the corners, forming channels connecting each source to individual detectors.
The prefrontal cortex is a region strongly associated with cognitive processing and plays a critical role in working memory tasks.
Task load was implemented through working memory tasks-a mechanism by which the brain temporarily processes and stores information crucial for handling complex cognitive demands.
Understanding how the amplitude of hemodynamic oscillations is modulated by different cognitive loads is significant, as microvascular blood flow is regulated by myogenic mechanisms.
These foundational insights will help improve the analysis and interpretation of hemodynamic neuroimaging data.
This study employs fNIRS, a non-invasive neuroimaging technique highly sensitive to microvascular activity, to investigate the interactive effects of cognitive load on brain hemodynamic LFOs.
研究概览
研究类型
观察性的
注册 (实际的)
47
联系人和位置
本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。
学习地点
-
-
Tianjin Municipality
-
Tianjin、Tianjin Municipality、中国、300192
- 16 channel fNIRS
-
-
参与标准
研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。
资格标准
适合学习的年龄
- 成人
接受健康志愿者
是的
取样方法
非概率样本
研究人群
47 right-handed volunteers (23 males and 24 females) were recruited.
Their ages ranged from 18 to 23 years, with an average age of 22.1 years for males and 21.5 years for females.
The participants were young adults, as the study aimed to investigate the effects of LFO on cognitive activation, which involved a relatively challenging 3-back working memory task.
All participants had normal or corrected-to-normal vision.
Female participants were excluded if they were within their menstrual cycle, as hormonal fluctuations during this period may affect certain prefrontal cortical functions.
None of the participants had a history of neurological or psychiatric disorders, nor were they taking any psychotropic medications.
Participants abstained from alcohol, caffeine, and nicotine for at least 24 hours prior to the experiment.
描述
Inclusion Criteria:
- Aged 18 to 23 years
- Right-hand
- Normal or corrected-to-normal vision
- Willing to abstain from alcohol, caffeine, and nicotine for at least 24 hours prior to the experiment
- Able to understand the study procedures and provide written informed consent
Exclusion Criteria:
- History of neurological or psychiatric disorders (e.g., epilepsy, severe insomnia, or anxiety)
- History of arrhythmia or other severe cardiovascular conditions
- Current or long-term use of psychotropic medications or other medications affecting the nervous system
- Contraindications for wearing skin-mounted optical devices
- Female participants currently in their menstrual cycle (due to potential hormonal effects on prefrontal cortical functions)
- Inability to follow experimental instructions or complete the testing tasks
学习计划
本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
No category
|
The investigators employed the N-back visual working memory task, a continuous letter task with varying working memory load demands.
The task consisted of four fixation blocks and three task blocks, lasting a total of 377 seconds.
Each fixation block lasted 20 seconds, during which participants were instructed to fixate their gaze on a central point.
The working memory load gradually increased from 1-back to 3-back across the task blocks.
Participants were required to determine whether the current letter matched the previous letter (1-back), the letter two positions back (2-back), or the letter three positions back (3-back) in terms of features, responding with one button for "yes" and another for "no."
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Peak Amplitude of Low-Frequency Oscillations (LFO) Measured by functional Near-Infrared Spectroscopy (fNIRS)
大体时间:Day1, The assessment time point was after the n-back task, with spectral analysis performed on low-frequency oscillation data collected during the 377-second n-back experiment.
|
|
Day1, The assessment time point was after the n-back task, with spectral analysis performed on low-frequency oscillation data collected during the 377-second n-back experiment.
|
|
Peak frequency of Low-Frequency Oscillations (LFO) Measured by fNIRS
大体时间:Day1, The assessment time point was after the n-back task, with spectral analysis performed on low-frequency oscillation data collected during the 377-second n-back experiment.
|
|
Day1, The assessment time point was after the n-back task, with spectral analysis performed on low-frequency oscillation data collected during the 377-second n-back experiment.
|
|
Power of Low-Frequency Oscillations (LFO) Measured by fNIRS
大体时间:Day1, The assessment time point was after the n-back task, with spectral analysis performed on low-frequency oscillation data collected during the 377-second n-back experiment.
|
|
Day1, The assessment time point was after the n-back task, with spectral analysis performed on low-frequency oscillation data collected during the 377-second n-back experiment.
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Reaction Time Assessed by N-back Behavioral Task System
大体时间:Day1, The assessment time point was after the n-back task, analyzing behavioral reaction times during the 377-second n-back experiment.
|
|
Day1, The assessment time point was after the n-back task, analyzing behavioral reaction times during the 377-second n-back experiment.
|
|
Accuracy Rate Assessed by N-back Behavioral Task System
大体时间:Day 1, the assessment time point was after the n-back task, analyzing behavioral accuracy rate during the 377-second n-back experiment.
|
|
Day 1, the assessment time point was after the n-back task, analyzing behavioral accuracy rate during the 377-second n-back experiment.
|
|
Correlation Between LFO Parameters and Task Behavioral Performance
大体时间:Day 1, the assessment time point was after the n-back task, analyzing behavioral correlation between low frequency oscillation parameters and task behavioral performance during the 377-second n-back experiment.
|
|
Day 1, the assessment time point was after the n-back task, analyzing behavioral correlation between low frequency oscillation parameters and task behavioral performance during the 377-second n-back experiment.
|
合作者和调查者
在这里您可以找到参与这项研究的人员和组织。
出版物和有用的链接
负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。
一般刊物
- [1] Biswal B, Zerrin Yetkin F, Haughton V M, et al. Functional connectivity in the motor cortex of resting human brain using echo-planar MRI[J]. Magnetic resonance in medicine, 1995, 34(4): 537-541. [2] Tong Y, Hocke L M, Licata S C, et al. Low-frequency oscillations measured in the periphery with near-infrared spectroscopy are strongly correlated with blood oxygen level-dependent functional magnetic resonance imaging signals[J]. Journal of biomedical optics, 2012, 17(10): 106004-106004. [3] Auer D P. Spontaneous low-frequency blood oxygenation level-dependent fluctuations and functional connectivity analysis of the 'resting'brain[J]. Magnetic resonance imaging, 2008, 26(7): 1055-1064. [4] Morita Y, Hardebo J E, Bouskela E. Influence of cerebrovascular sympathetic, parasympathetic, and sensory nerves on autoregulation and spontaneous vasomotion[J]. Acta physiologica scandinavica, 1995, 154(2): 121-130 [5] Vern B A, Schuette W H, Leheta B, et al. Low-frequency oscillations of cortical oxidative metabolism in waking and sleep[J]. Journal of Cerebral Blood Flow & Metabolism, 1988, 8(2): 215-226. [6] Lin PY, Roche-Labarbe N, Dehaes M, Carp S, Fenoglio A, Barbieri B, Hagan K, Grant PE, Franceschini MA. Non-invasive optical measurement of cerebral metabolism and hemodynamics in infants. J Vis Exp. 2013 Mar 14;(73):e4379. [7] Diehl R R, Linden D, Lücke D, et al. Spontaneous blood pressure oscillations and cerebral autoregulation[J]. Clinical Autonomic Research, 1998, 8(1): 7-12. [8] Katura T, Tanaka N, Obata A, et al. Quantitative evaluation of interrelations between spontaneous low-frequency oscillations in cerebral hemodynamics and systemic cardiovascular dynamics[J]. Neuroimage, 2006, 31(4): 1592-1600. [9] Cui X, Bray S, Bryant DM, Glover GH, Reiss AL. A quantitative comparison of NIRS and fMRI across multiple cognitive tasks. Neuroimage. 2011 Feb 14;54(4):2808-21. [10] Biswal B B, Kylen J V, Hyde J S. Simultaneous assessment of flow and BOLD signals in resting-state fu
研究记录日期
这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。
研究主要日期
学习开始 (实际的)
2025年6月1日
初级完成 (实际的)
2025年7月1日
研究完成 (实际的)
2025年10月1日
研究注册日期
首次提交
2026年6月24日
首先提交符合 QC 标准的
2026年8月6日
首次发布 (实际的)
2026年8月12日
研究记录更新
最后更新发布 (实际的)
2026年8月12日
上次提交的符合 QC 标准的更新
2026年8月6日
最后验证
2026年8月1日
更多信息
与本研究相关的术语
其他研究编号
- 2025(I)-203-01
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
不
IPD 计划说明
Protection of personal information and privacy of participants
药物和器械信息、研究文件
研究美国 FDA 监管的药品
不
研究美国 FDA 监管的设备产品
不
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.