此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Hemodynamic Effects of Bilateral and Unilateral Spinal Anesthesia Using the Continuous Pressure Recording Analytical Method.

2026年8月24日 更新者:Ayşe Temiz、Kayseri City Hospital

Comparison of the Hemodynamic Effects of Bilateral and Unilateral Spinal Anesthesia in Hip Arthroplasty Surgeries in Elderly Patients Using the Continuous Pressure Recording Analytical Method.

This randomized controlled study aims to compare the intraoperative hemodynamic effects of unilateral and bilateral spinal anesthesia in elderly patients undergoing elective total hip arthroplasty. Seventy-four patients aged 65 years and older will be randomized into two groups: unilateral spinal anesthesia (n=37) and bilateral spinal anesthesia (n=37).

Hemodynamic parameters including cardiac output, stroke volume, stroke volume variation, pulse pressure variation, and systemic vascular resistance will be continuously monitored using the Pressure Recording Analytical Method (PRAM)-based MostCare monitoring system. Intraoperative fluid requirements and vasopressor consumption will also be evaluated.

The study seeks to determine whether unilateral spinal anesthesia provides greater hemodynamic stability and reduces the need for fluid administration and vasopressor support compared with conventional bilateral spinal anesthesia in elderly patients undergoing hip arthroplasty.

研究概览

详细说明

Hip arthroplasty is a commonly performed orthopedic procedure in elderly patients. Due to age-related physiological changes and the high prevalence of cardiovascular comorbidities, maintenance of intraoperative hemodynamic stability is essential in this population. Spinal anesthesia is widely used for lower extremity orthopedic surgery; however, sympathetic blockade may result in hypotension and impaired tissue perfusion, particularly in elderly patients.

Unilateral spinal anesthesia has been proposed as an alternative technique that may reduce the extent of sympathetic blockade and provide greater cardiovascular stability compared with conventional bilateral spinal anesthesia. Nevertheless, evidence regarding the advanced hemodynamic effects of these two techniques remains limited.

This prospective randomized controlled study aims to compare the hemodynamic effects of unilateral and bilateral spinal anesthesia in patients aged 65 years and older undergoing elective total hip arthroplasty. A total of 74 patients will be randomized to receive either unilateral spinal anesthesia (n=37) or bilateral spinal anesthesia (n=37).

Before spinal anesthesia, all participants will receive standard sedation with fentanyl (1-2 mcg/kg) and midazolam (0.015-0.03 mg/kg). Hemodynamic monitoring will be performed using the MostCare monitoring system based on the Pressure Recording Analytical Method (PRAM) through a radial arterial catheter.

The following hemodynamic parameters will be recorded at baseline, immediately after spinal anesthesia, and at predefined intraoperative time points: heart rate (HR), mean arterial pressure (MAP), peripheral oxygen saturation (SpO2), cardiac index (CI), stroke volume index (SVI), stroke volume variation (SVV), pulse pressure variation (PPV), systemic vascular resistance (SVR), oxygen delivery (DO2), oxygen delivery index (DO2I), maximal pressure rise during systole (dP/dtmax), cardiac cycle efficiency (CCE), and arterial elastance (Ea).

In addition, intraoperative vasopressor requirement (ephedrine use) and operative duration will be recorded and compared between study groups.

The primary objective is to determine whether unilateral spinal anesthesia provides superior hemodynamic stability compared with bilateral spinal anesthesia in elderly patients undergoing hip arthroplasty. The investigators hypothesize that unilateral spinal anesthesia will be associated with reduced hemodynamic fluctuations and lower vasopressor requirements compared with bilateral spinal anesthesia.

研究类型

介入性

注册 (估计的)

74

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  1. Adults aged 65 years and older.
  2. Patients scheduled for elective total hip arthroplasty.
  3. Patients with an American Society of Anesthesiologists (ASA) physical status classification of II, III, or IV.
  4. Patients with a Glasgow Coma Scale (GCS) score of 13-15 who are conscious and able to cooperate.
  5. Patients with suitable peripheral arterial anatomy for PRAM monitoring.
  6. Patients who provide written informed consent to participate in the study.
  7. Patients without any clinical contraindication to spinal anesthesia. -

Exclusion Criteria:

  1. Glasgow Coma Scale (GCS) score <13.
  2. Age below 65 years.
  3. History of previous major neurosurgical intervention.
  4. Anatomical abnormality, vascular defect, or infection at the site intended for arterial catheter placement for PRAM monitoring.
  5. Severe spinal deformity (e.g., severe scoliosis, previous spinal fusion surgery, or spinal trauma).
  6. Current anticoagulant therapy or coagulopathy (INR >1.5 or platelet count <75,000/mm³).
  7. Presence of skin infection or systemic infection/sepsis.
  8. Severe hypovolemia or decompensated cardiac disease in which spinal anesthesia is contraindicated.
  9. Known allergy or hypersensitivity to local anesthetics or sedative agents.
  10. Local infection or wound at the planned spinal puncture site.
  11. Clinical contraindication to spinal anesthesia (e.g., increased intracranial pressure, septicemia, or severe hypotension). -

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:其他
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Unilateral Spinal Anesthesia
Patients receive unilateral spinal anesthesia and hemodynamic parameters are monitored using the PRAM method during surgery.
Unilateral spinal anesthesia administered for unilateral lower extremity surgery.
实验性的:Bilateral Spinal Anesthesia
Patients receive bilateral spinal anesthesia and hemodynamic parameters are monitored using the PRAM method during surgery.
Bilateral spinal anesthesia administered for unilateral lower extremity surgery.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Cardiac Index Measured Using PRAM During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Cardiac index will be measured using the Pressure Recording Analytical Method (PRAM) and reported in L/min/m². Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Stroke Volume Index Measured Using PRAM During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Stroke volume index will be measured using the Pressure Recording Analytical Method (PRAM) and reported in mL/beat/m². Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Stroke Volume Variation Measured Using PRAM During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Stroke volume variation will be measured using the Pressure Recording Analytical Method (PRAM) and reported as a percentage. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Pulse Pressure Variation Measured Using PRAM During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Pulse pressure variation will be measured using the Pressure Recording Analytical Method (PRAM) and reported as a percentage. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Systemic Vascular Resistance Measured Using PRAM During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Systemic vascular resistance will be measured using the Pressure Recording Analytical Method (PRAM) and reported in dyn·s/cm⁵. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Oxygen Delivery Index Measured Using PRAM During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Oxygen delivery index will be measured using the Pressure Recording Analytical Method (PRAM) and reported in mL/min/m². Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Arterial Elastance Measured Using PRAM During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Arterial elastance will be measured using the Pressure Recording Analytical Method (PRAM) and reported in mmHg/mL. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Maximum Rate of Arterial Pressure Rise Measured Using PRAM
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
The maximum rate of arterial pressure rise (dP/dtmax) will be measured using the Pressure Recording Analytical Method (PRAM) and reported in mmHg/s. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Cardiac Cycle Efficiency Measured Using PRAM
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Cardiac cycle efficiency (CCE) will be measured using the Pressure Recording Analytical Method (PRAM) and reported as a dimensionless value. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Oxygen Delivery Measured Using PRAM During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Oxygen delivery (DO₂) will be measured using the Pressure Recording Analytical Method (PRAM) and reported in mL/min. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Mean Arterial Pressure During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Mean arterial pressure (MAP) will be measured using invasive arterial pressure monitoring and reported in mmHg. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Heart Rate During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Heart rate (HR) will be recorded using standard perioperative monitoring and reported in beats per minute. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Peripheral Oxygen Saturation During Spinal Anesthesia
大体时间:From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.
Peripheral oxygen saturation (SpO₂) will be measured using pulse oximetry and reported as a percentage. Measurements recorded at each study time point will be compared between the unilateral and bilateral spinal anesthesia groups.
From immediately before spinal anesthesia until completion of surgery, assessed at baseline and every 10 minutes for up to 180 minutes.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年5月1日

初级完成 (估计的)

2026年8月31日

研究完成 (估计的)

2026年8月31日

研究注册日期

首次提交

2026年6月11日

首先提交符合 QC 标准的

2026年8月24日

首次发布 (实际的)

2026年8月27日

研究记录更新

最后更新发布 (实际的)

2026年8月27日

上次提交的符合 QC 标准的更新

2026年8月24日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅