此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Mechanical Resistance Curves of the NTLC75 Linear Stapler During Barcelona Ileotransverse Anastomosis (NTLC75-ITA)

2026年9月15日 更新者:Ognjen Barčot, MD, PhD、University Hospital of Split

Relative Mechanical Resistance Curves of the NTLC75 Linear Stapler During Barcelona Ileotransverse Anastomosis After Right Colectomy: A Prospective Observational Pilot Study

This prospective single-center pilot cohort will include 40 consecutive adults undergoing elective right colectomy with a Barcelona ileotransverse anastomosis using an NTLC75/SR75 linear stapler. A sensor mounted externally on the stapler handle will record relative mechanical signals during two calibration closures without firing and two standard stapler activations. The main objectives are to obtain at least 35 technically valid final cross-stapling recordings and to estimate the association between the normalized final maximum signal and C-reactive protein on postoperative day 3. Clinical treatment is unchanged and follow-up continues through postoperative day 90.

研究概览

详细说明

Two close-only calibration measurements will be recorded once on double-walled small bowel and colon located on the resection-specimen side, outside the tumor and resection margins, with the anvil toward the mesentery, without firing or consuming additional reloads. The first standard activation forms the ileotransverse anastomotic channel without cross-stapling, with the anvil in the colon and reload jaw in the small bowel. The final closure is oriented with the device tip toward the small bowel so that knife travel proceeds from colon to small bowel and crosses two existing staple lines. The surgeon measures flattened tissue lengths and both cross-stapling distances with a sterile ruler to the nearest whole millimeter. Raw signals are preserved; forward and return branches are resampled to 200 normalized-time points. The signal is not calibrated as absolute force, is not shown to the surgeon and does not influence care. Other curve features and clinical outcomes are exploratory.

研究类型

观察性的

注册 (估计的)

40

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

      • Split、克罗地亚、21000
        • University Hospital of Split, Department of Surgery
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

非概率样本

研究人群

Adults scheduled for elective right colectomy for operable right-sided colon cancer with planned primary Barcelona ileotransverse anastomosis using NTLC75/SR75.

描述

Inclusion Criteria:

  • Age 18 years or older
  • Elective right colectomy for histologically confirmed or clinically or radiologically suspected operable right-sided colon cancer
  • Planned primary Barcelona ileotransverse anastomosis using NTLC75/SR75
  • Capacity to understand the study and provide written informed consent

Exclusion Criteria:

  • Emergency surgery
  • No planned or performed primary anastomosis
  • Another anastomotic technique or stapler model
  • Withdrawal or inability to consent
  • Intraoperative change of plan preventing the planned measurement procedure

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 观测模型:COHORT
  • 时间观点:PROSPECTIVE

队列和干预

团体/队列
干预/治疗
Elective Right Colectomy Cohort

Adults undergoing elective right colectomy with a Barcelona ileotransverse anastomosis using NTLC75/SR75 as standard clinical care. Relative mechanical signals are recorded passively during two close-only calibration closures without firing and two standard stapler activations.

An external DF9-40 sensor mounted on the NTLC75 handle passively records relative mechanical signals. One close-only calibration recording is obtained on double-walled small bowel and one on double-walled colon on the resection-specimen side, outside the tumor and resection margins, with the anvil toward the mesentery, without firing. Signals are also recorded during standard ITA channel formation (anvil in colon; reload jaw in small bowel; no cross-stapling) and final closure (tip toward small bowel; knife travel from colon to small bowel across two existing staple lines). The signal is not shown to the surgeon and does not affect clinical care.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Participants With a Technically Valid Final Cross-Stapling Signal Record
大体时间:Intraoperative, during the final cross-stapling activation

Number and percentage of all 40 enrolled participants with a complete and technically valid final cross-stapling signal record. A valid record includes a complete forward branch, an identifiable reference return branch, no peak-obscuring saturation, no loss of sensor contact, and successful application of the locked signal-processing algorithm. Missing or invalid records remain in the denominator. Prespecified feasibility target: at least 35 of 40 participants.

Intraoperative, during the final cross-stapling activation
C-Reactive Protein Concentration on Postoperative Day 3 in Relation to the Normalized Final Maximum Signal
大体时间:Postoperative day 3

Routine-care serum C-reactive protein in mg/L, analyzed continuously in association with the normalized maximum amplitude of the final cross-stapling forward branch using a scatterplot, Pearson or Spearman correlation, and simple linear regression.

Postoperative day 3

次要结果测量

结果测量
措施说明
大体时间
CloseMax During Small-Bowel Close-Only Calibration
大体时间:Intraoperative, during the small-bowel close-only calibration

Maximum baseline-corrected relative signal amplitude during complete stapler closure on the double-walled small bowel located on the resection-specimen side, without firing. Reported in relative signal units.

Intraoperative, during the small-bowel close-only calibration
Maximum Signal Amplitude During ITA and Final Cross-Stapling Activations
大体时间:Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations

Maximum baseline-corrected amplitude of each forward and return signal branch, calculated separately for the ileotransverse anastomotic-channel and final cross-stapling activations. Reported in relative signal units.

Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations
Inter-Rater Agreement for Manual Curve Classification
大体时间:Through study completion and before database lock, an anticipated 16 months

Two independent raters blinded to C-reactive protein values and clinical outcomes classify technical validity, curve morphology, sticking, and irregularity for the ileotransverse anastomotic-channel and final cross-stapling recordings. Agreement between the two initial categorical ratings is quantified using Cohen's kappa before consensus resolution.

Through study completion and before database lock, an anticipated 16 months
C-Reactive Protein Concentration
大体时间:Postoperative days 1 and 3

Routine-care serum C-reactive protein concentration recorded separately on postoperative days 1 and 3 and reported in mg/L. The prespecified association between postoperative-day-3 CRP and the normalized final cross-stapling maximum remains the second primary outcome.

Postoperative days 1 and 3
Highest Clavien-Dindo Complication Grade
大体时间:From the index operation through postoperative day 90

Highest Clavien-Dindo grade assigned to any postoperative complication experienced by each participant through postoperative day 90. Participants without a complication are recorded as having no Clavien-Dindo complication.

From the index operation through postoperative day 90
Participants With Anastomosis-Related Events
大体时间:From the index operation through postoperative day 90

Number and percentage of participants with anastomotic leak, anastomotic bleeding, perianastomotic collection or abscess, anastomosis-related radiologic or endoscopic intervention, reoperation, or surgical revision. Each event type is reported separately.

From the index operation through postoperative day 90
Length of Postoperative Hospital Stay
大体时间:From the index operation to discharge from the index hospitalization, assessed through postoperative day 90

Number of calendar days from the index operation to discharge from the index hospitalization.

From the index operation to discharge from the index hospitalization, assessed through postoperative day 90
CloseMax During Colon Close-Only Calibration
大体时间:Intraoperative, during the colon close-only calibration

Maximum baseline-corrected relative signal amplitude during complete stapler closure on the double-walled colon located on the resection-specimen side, without firing. Reported in relative signal units.

Intraoperative, during the colon close-only calibration
CloseMax During Ileotransverse Anastomotic Channel Formation
大体时间:Intraoperative, during the stapler activation forming the ileotransverse anastomotic channel

Maximum baseline-corrected relative signal amplitude during the closing phase preceding the standard stapler activation used to form the ileotransverse anastomotic channel without cross-stapling. Reported in relative signal units.

Intraoperative, during the stapler activation forming the ileotransverse anastomotic channel
CloseMax During Final Cross-Stapling
大体时间:Intraoperative, during the final cross-stapling activation

Maximum baseline-corrected relative signal amplitude during the closing phase preceding the final cross-stapling activation. Reported in relative signal units.

Intraoperative, during the final cross-stapling activation
Normalized Time to Maximum Signal Amplitude
大体时间:Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations

Position of the maximum baseline-corrected amplitude within each signal branch, expressed as a percentage of that branch's total duration from 0% to 100%. Calculated separately for the forward and return branches of both activations.

Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations
Signal-Branch Duration During ITA and Final Cross-Stapling Activations
大体时间:Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations

Actual elapsed duration of each forward and return signal branch, calculated separately for the ileotransverse anastomotic-channel and final cross-stapling activations. Reported in seconds from the preserved raw timestamps.

Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations
Signal Peak Count During ITA and Final Cross-Stapling Activations
大体时间:Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations

Number of signal peaks identified by the locked signal-processing algorithm in each 200-point normalized-time branch. Calculated separately for the forward and return branches of both activations.

Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations
Maximum Signal Slope During ITA and Final Cross-Stapling Activations
大体时间:Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations

Maximum positive slope of each 200-point normalized-time signal branch, calculated using the locked signal-processing algorithm. Reported in relative signal units per normalized-time point and calculated separately for both activations.

Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations
Area Under the Signal Curve During ITA and Final Cross-Stapling Activations
大体时间:Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations

Area under each baseline-corrected 200-point normalized-time signal branch, calculated separately for the forward and return branches of both activations. Reported in relative signal units multiplied by normalized time.

Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations
Signal Amplitude Variability During ITA and Final Cross-Stapling Activations
大体时间:Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations

Standard deviation of the baseline-corrected amplitudes across each 200-point normalized-time signal branch. Calculated separately for the forward and return branches of both activations and reported in relative signal units.

Intraoperative, during the ileotransverse anastomotic-channel and final cross-stapling activations
Leukocyte Count
大体时间:Postoperative days 1 and 3

Routine-care peripheral blood leukocyte count recorded separately on postoperative days 1 and 3 and reported as ×10^9/L.

Postoperative days 1 and 3
Neutrophil Count
大体时间:Postoperative days 1 and 3

Routine-care peripheral blood absolute neutrophil count recorded separately on postoperative days 1 and 3 and reported as ×10^9/L.

Postoperative days 1 and 3
Lymphocyte Count
大体时间:Postoperative days 1 and 3

Routine-care peripheral blood absolute lymphocyte count recorded separately on postoperative days 1 and 3 and reported as ×10^9/L.

Postoperative days 1 and 3
Neutrophil-to-Lymphocyte Ratio
大体时间:Postoperative days 1 and 3

Neutrophil-to-lymphocyte ratio calculated from the absolute neutrophil and lymphocyte counts obtained on the same postoperative day. Recorded separately on postoperative days 1 and 3 and reported as a unitless ratio.

Postoperative days 1 and 3
Serum Albumin Concentration
大体时间:Postoperative days 1 and 3

Routine-care serum albumin concentration recorded separately on postoperative days 1 and 3 and reported in g/L.

Postoperative days 1 and 3
Serum Creatinine Concentration
大体时间:Postoperative days 1 and 3

Routine-care serum creatinine concentration recorded separately on postoperative days 1 and 3 and reported in µmol/L.

Postoperative days 1 and 3
Estimated Glomerular Filtration Rate
大体时间:Postoperative days 1 and 3

Laboratory-reported estimated glomerular filtration rate recorded separately on postoperative days 1 and 3 and reported in mL/min/1.73 m².

Postoperative days 1 and 3
Participants With a Major Postoperative Complication
大体时间:From the index operation through postoperative day 90

Number and percentage of participants experiencing at least one major postoperative complication, defined as Clavien-Dindo grade III, IV, or V.

From the index operation through postoperative day 90
Comprehensive Complication Index Score
大体时间:From the index operation through postoperative day 90

Comprehensive Complication Index score calculated from all postoperative complications experienced by each participant through postoperative day 90. Reported on the standard continuous scale from 0, indicating no complication, to 100, indicating death.

From the index operation through postoperative day 90
Participants With All-Cause Readmission Within 30 Days
大体时间:From discharge after the index hospitalization through postoperative day 30

Number and percentage of participants with at least one unplanned all-cause hospital readmission by postoperative day 30.

From discharge after the index hospitalization through postoperative day 30
Participants Undergoing Reoperation Within 30 Days
大体时间:From the index operation through postoperative day 30

Number and percentage of participants undergoing at least one unplanned surgical reoperation for any cause by postoperative day 30.

From the index operation through postoperative day 30
All-Cause Mortality Within 30 Days
大体时间:From the index operation through postoperative day 30

Number and percentage of participants who die from any cause by postoperative day 30.

From the index operation through postoperative day 30
All-Cause Mortality Within 90 Days
大体时间:From the index operation through postoperative day 90

Number and percentage of participants who die from any cause by postoperative day 90.

From the index operation through postoperative day 90

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年10月1日

初级完成 (估计的)

2027年11月3日

研究完成 (估计的)

2028年1月29日

研究注册日期

首次提交

2026年9月8日

首先提交符合 QC 标准的

2026年9月15日

首次发布 (实际的)

2026年9月22日

研究记录更新

最后更新发布 (实际的)

2026年9月22日

上次提交的符合 QC 标准的更新

2026年9月15日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Patient-level data will not be made public because the small single-center surgical cohort carries a material re-identification risk.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.