此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Mulligan Techniques for Gait and Pelvic Motion in Short Hamstrings

2026年9月25日 更新者:Gamze COBANOGLU、Gazi University

The Effect of Two Different Mulligan Techniques on Spatiotemporal Parameters and Pelvic Oscillation in Individuals With Hamstring Tightness: A Randomized Controlled Trial

Various stretching methods have been developed to reduce hamstring tightness and improve flexibility. Static stretching is one of the safest and most common methods used to increase muscle length; however, its effect is temporary and diminishes rapidly. Additionally, such conventional methods can be uncomfortable and require longer periods to yield visible results. Unlike other mobilization procedures, the Mulligan concept is performed while patients execute a resisted muscle contraction or move actively or passively. Distinct from many other manual therapy approaches, this technique is applied within a symptom-free range of motion, which likely enhances its safety. Traction Straight Leg Raise (TSLR) and Bent Leg Raise (BLR) techniques are specific interventions defined by Mulligan. There are limited studies in the literature investigating the effects of these two techniques on hamstring flexibility. However, no study has compared these two techniques in terms of spatiotemporal gait parameters and pelvic oscillations. Therefore, the purpose of this study is to compare the effects of BLR and TSLR techniques applied to individuals with hamstring tightness on hamstring flexibility, spatiotemporal parameters of gait, and pelvic oscillations.

研究概览

详细说明

Flexibility holds a significant place among health-related physical fitness parameters and is defined as the normal range of motion achievable by a joint and/or joint complexes. Muscle flexibility is crucial for maintaining optimal muscle functionality and proper biomechanics. Limited flexibility leads to various musculoskeletal symptoms, postural deformities, and gait limitations. Reduced flexibility is commonly observed in fast-twitch and biarticular muscles, with the hamstring muscles being a prime example. The length of the hamstring muscles plays an essential role in human movement, including gait. Hamstring tightness reduces the ability to absorb shocks applied to the lower extremity and knee extension during walking, thereby decreasing step length. Individuals with hamstring tightness do not exhibit a normal gait pattern, particularly during the mid-swing and terminal swing phases. Furthermore, hamstring tightness results in reduced pelvic mobility. Decreased hamstring flexibility is a frequently observed finding in numerous musculoskeletal problems of the knee, hip, and lumbar regions. By disrupting the muscle length-tension relationship in the posterior kinetic chain, it has been specifically associated with clinical conditions such as low back pain, patellofemoral pain syndrome, and posterior pelvic tilt. Therefore, addressing this tightness stands out as a major goal in rehabilitation and exercise programs. Traction Straight Leg Raise (TSLR) and Bent Leg Raise (BLR) techniques are specific interventions. Only a limited number of studies have compared these two methods in individuals with hamstring tightness. Kapadia and Meshram reported that both of Mulligan's TSLR and BLR techniques are effective in improving hamstring muscle flexibility in healthy individuals; however, they noted that the TSLR technique was superior in enhancing flexibility. Priyanka et al. applied TSLR and BLR interventions to collegiate cricket players for a duration of two weeks and concluded that the BLR technique was more effective in increasing hamstring muscle flexibility compared to the TSLR technique. Furthermore, Bhosle and Rizvi investigated the treatment of sewing machine operators with hamstring tightness and low back pain, finding that both Mulligan BLR and TSLR techniques were effective in increasing hamstring flexibility and reducing low back pain-related disability, with no significant superiority of one technique over the other.

A review of the current literature reveals conflicting results regarding the efficacy of these techniques on hamstring flexibility. Furthermore, no study to date has compared these two techniques in terms of spatiotemporal gait parameters and pelvic oscillations. Therefore, the purpose of this study is to compare the effects of Mulligan TSLR and BLR techniques on hamstring flexibility, spatiotemporal gait parameters, and pelvic oscillations in individuals with hamstring tightness.

研究类型

介入性

注册 (实际的)

34

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 35年 (成人)

接受健康志愿者

是的

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Individuals between the ages of 18 and 35
  • Individuals who bilateral hamstring shortness

Exclusion Criteria:

  • A passive knee extension angle of 20° or less
  • A history of lower extremity pain or injury within the last 6 months
  • Previous lower extremity surgery
  • Neurological, rheumatological, or systemic diseases
  • Poor cooperation for activities
  • Regular participation in sports.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
实验性的:Mulligan Bent Leg Raise (BLR) Technique

17 individuals in this group, after evaluations, mobilization with movement technique applied by clinians and after that same evaluations will be applied.

The participant's flexed knee was supported on the therapist's shoulder. Following a resisted leg push and relaxation, the therapist passively moved the knee toward the ipsilateral shoulder to the maximum pain-free range. If pain occurred, the leg was shifted medially or laterally to find a pain-free pathway.

实验性的:Mulligan Traction Straight Leg Raise (TSLR) Technique

17 individuals in this group, after evaluations, mobilization with movement technique applied by clinians and after that same evaluations will be applied.

In a supine position with the knee extended and hip neutral, maximum longitudinal traction was applied to the lower extremity. The limb was passively raised (SLR) until the onset of discomfort and immediately returned to the resting position. If pain was indicated, the movement direction was modified by adding abduction and/or rotation to ensure a pain-free pathway.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Passive knee extension test
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

the participant was supine with the tested hip flexed to 90° and the femur stabilized. The contralateral leg remained flat on the table. A goniometer was placed with its axis on the lateral femoral epicondyle, the stationary arm aligned with the greater trochanter, and the moving arm with the lateral malleolus. The knee was passively extended until a stretch was felt or hip flexion was compromised, marking the test endpoint.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

次要结果测量

结果测量
措施说明
大体时间
Cadence (step / min) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

"Cadence" (steps/min) is the number of steps in a minute. Cadence during gait was assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.
Speed (m / s) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later

Speed (m/s) parameters is average walking speed. Speed during gait was assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later
Gait cycle duration (s) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later

Gait cycle duration (s) parameter is average value of the time interval between two consecutive heel strikes of the same foot. Gait cycle duration were assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later
Stride length (m) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

Stride length (m) is the average value of distances between each initial contact and the next one of the same side. Stride length during gait was assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.
Stance phase (% cycle) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

Stance phase (% cycle) is the average value of the duration of the right and left foot support phase as percentage of the gait cycle. Stance phase during gait was assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.
Swing phase (% cycle) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

Swing phase (% cycle) is average value of the duration of the right and left swing phase as percentage of the gait cycle. Swing phase during gait was assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.
Pelvic tilt range (degrees) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

The angles average value described by the pelvis in the 3 main body planes (sagittal, frontal and transversal), are represented in three graphs: The sagittal plane component describes the pelvic tilt. Pelvic tilt range during gait were assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.
Pelvic obliquity range (degrees) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

The angles average value described by the pelvis in the 3 main body planes (sagittal, frontal and transversal), are represented in three graphs: the frontal plane component describes the pelvic obliquity. Pelvic obliquity range during gait analysis was assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.
Pelvic rotation range (degrees) during gait
大体时间:Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

The angles average value described by the pelvis in the 3 main body planes (sagittal, frontal and transversal), are represented in three graphs: the transversal plane component describes the pelvic rotation. Pelvic rotation range during gait were assessed using a BTS G-Walk accelerometer secured at the L4-L5 level. Participants walked at a normal pace along a 10-meter marked track and returned. Data were transmitted via Bluetooth to G-Studio software for analysis.

Measurements were taken at three time points: before the intervention, immediately following the intervention, and 24 hours later.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2025年6月20日

初级完成 (实际的)

2025年9月1日

研究完成 (实际的)

2026年1月10日

研究注册日期

首次提交

2026年9月14日

首先提交符合 QC 标准的

2026年9月25日

首次发布 (实际的)

2026年9月29日

研究记录更新

最后更新发布 (实际的)

2026年9月29日

上次提交的符合 QC 标准的更新

2026年9月25日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • 2025 - 977

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅