此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Acute Effects of Variable-Resistance and Free-Weight Bench Pull Exercise in Resistance-Trained Men

2026年9月22日 更新者:Zongwei Chen、South China Normal University

Acute Comparison of High-Load Variable-Resistance and Free-Weight Bench Pulls: A Randomized Crossover Study of Exercise Responses and Residual Effects

This study used a randomized, counterbalanced crossover design to compare high-load chain-based variable-resistance (VR) and free-weight (FW) bench pulls. Resistance-trained men completed two experimental sessions separated by 72 hours, with the order of the VR and FW conditions randomized.

Before each experimental condition, participants completed a standardized general and bench pull-specific warm-up followed by a 10-minute rest period. In each session, participants performed one set of three bench pull repetitions at approximately 85% of their free-weight one-repetition maximum (1RM). In the VR condition, the external resistance was provided by a combination of barbell load and chains, with chains contributing approximately 20% of the effective mean total load. In the FW condition, the external resistance was provided entirely by the barbell.

Following the high-load bench pull, participants rested for 3 minutes and then completed three standardized sets of free-weight bench pulls at approximately 75% 1RM, with 3-minute rest intervals between sets. Each subsequent set was terminated when the mean velocity of a repetition fell below 0.65 m·s-¹ or when the participant was unable to complete the prescribed range of motion.

Direct exercise responses during the high-load bench pulls were assessed using movement velocity and surface electromyography. Residual effects during the subsequent free-weight sets were assessed using repetition count, movement velocity, and surface electromyography. The crossover design allowed each participant to complete both loading conditions and therefore serve as his own control.

研究概览

详细说明

This study used a randomized, counterbalanced crossover design to compare the acute effects of high-load chain-based variable resistance (VR) and free-weight (FW) resistance during the bench pull exercise. Resistance-trained men completed both experimental conditions in separate sessions, with the order of conditions randomized and the sessions separated by 72 hours.

Before each experimental condition, participants completed a standardized general warm-up and a bench pull-specific warm-up, followed by a 10-minute rest period. In each session, participants performed one set of three bench pull repetitions at approximately 85% of their free-weight one-repetition maximum (1RM). In the VR condition, external resistance was provided by a combination of barbell load and chains, with chains contributing approximately 20% of the effective mean total load. In the FW condition, external resistance was provided entirely by the barbell.

After the high-load bench pull, participants rested for 3 minutes and then completed three standardized sets of free-weight bench pulls at approximately 75% 1RM, with 3-minute rest intervals between sets. Each subsequent set was terminated when the mean velocity of a repetition fell below 0.65 m·s-¹ or when the participant was unable to complete the prescribed range of motion.

Movement velocity and surface electromyography were recorded during the high-load bench pulls to evaluate direct exercise responses. During the subsequent free-weight sets, repetition count, movement velocity, and surface electromyography were assessed to evaluate residual effects of the preceding high-load condition. The crossover design allowed each participant to complete both loading conditions and therefore serve as his own control.

研究类型

介入性

注册 (实际的)

15

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Tianjin Municipality
      • Tianjin、Tianjin Municipality、中国、510760
        • Tianjin University of Sport

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 30年 (成人)

接受健康志愿者

是的

有资格学习的性别

男性

描述

Inclusion Criteria:

  • Male adults aged 18-30 years.
  • At least 1 year of resistance-training experience.
  • Proficiency in the bench-pull technique.
  • Bench-pull one-repetition maximum (1RM) of at least 1.0 × body mass.
  • No current use of medications that could affect neuromuscular performance.
  • No history of cardiovascular, neurological, or metabolic disease.
  • No upper-body musculoskeletal injury within the previous year.
  • Willing and able to provide written informed consent.

Exclusion Criteria:

  • Consumption of caffeine within 12 hours before testing.
  • Consumption of alcohol within 24 hours before testing.
  • Performance of any upper-body pulling exercise within 48 hours before testing.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:基础科学
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Variable Resistance, Then Free Weight

Participants completed the high-load variable-resistance bench-pull condition during the first experimental session and the high-load free-weight bench-pull condition during the second experimental session. The two sessions were separated by 72 hours. In each session, the high-load bench pull was followed after 3 minutes by three standardized free-weight bench-pull sets at approximately 75% of one-repetition maximum.

Participants performed one set of three bench-pull repetitions at approximately 85% of their free-weight one-repetition maximum. External resistance was provided by a combination of barbell load and chains, with the chains contributing approximately 20% of the effective mean total load. Participants were instructed to perform the concentric phase with maximal intended velocity. After the high-load bench pull, participants rested for 3 minutes and then completed three standardized free-weight bench-pull sets at approximately 75% of one-repetition maximum, with 3-minute rest intervals between sets. Each subsequent set was terminated when mean repetition velocity fell below 0.65 m·s-¹ or when the prescribed range of motion could not be completed.

Participants performed one set of three bench-pull repetitions at approximately 85% of their free-weight one-repetition maximum, with the external resistance provided entirely by the barbell. Participants were instructed to perform the concentric phase with maximal intended velocity. After the high-load bench pull, participants rested for 3 minutes and then completed three standardized free-weight bench-pull sets at approximately 75% of one-repetition maximum, with 3-minute rest intervals between sets. Each subsequent set was terminated when mean repetition velocity fell below 0.65 m·s-¹ or when the prescribed range of motion could not be completed.

实验性的:Free Weight, Then Variable Resistance

Participants completed the high-load free-weight bench-pull condition during the first experimental session and the high-load variable-resistance bench-pull condition during the second experimental session. The two sessions were separated by 72 hours. In each session, the high-load bench pull was followed after 3 minutes by three standardized free-weight bench-pull sets at approximately 75% of one-repetition maximum.

Participants performed one set of three bench-pull repetitions at approximately 85% of their free-weight one-repetition maximum. External resistance was provided by a combination of barbell load and chains, with the chains contributing approximately 20% of the effective mean total load. Participants were instructed to perform the concentric phase with maximal intended velocity. After the high-load bench pull, participants rested for 3 minutes and then completed three standardized free-weight bench-pull sets at approximately 75% of one-repetition maximum, with 3-minute rest intervals between sets. Each subsequent set was terminated when mean repetition velocity fell below 0.65 m·s-¹ or when the prescribed range of motion could not be completed.

Participants performed one set of three bench-pull repetitions at approximately 85% of their free-weight one-repetition maximum, with the external resistance provided entirely by the barbell. Participants were instructed to perform the concentric phase with maximal intended velocity. After the high-load bench pull, participants rested for 3 minutes and then completed three standardized free-weight bench-pull sets at approximately 75% of one-repetition maximum, with 3-minute rest intervals between sets. Each subsequent set was terminated when mean repetition velocity fell below 0.65 m·s-¹ or when the prescribed range of motion could not be completed.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Average Mean and Peak Velocity During the High-Load Bench Pull
大体时间:Day 1 and Day 4, during the high-load bench-pull set

Movement velocity was measured using a linear position transducer sampling at 100 Hz. Mean velocity and peak velocity were obtained for each of the three repetitions performed during the high-load bench-pull set. For each loading condition, average mean velocity and average peak velocity were calculated by averaging the corresponding values across the three repetitions. Velocity was expressed in meters per second (m·s-¹).

Day 1 and Day 4, during the high-load bench-pull set
Normalized Surface Electromyography Amplitude During the High-Load Bench Pull
大体时间:Day 1 and Day 4, during the high-load bench-pull set

Surface electromyography was recorded from the right latissimus dorsi, teres major, posterior deltoid, and middle trapezius. Root mean square amplitudes were normalized to the maximal root mean square amplitude obtained during maximal voluntary isometric contraction testing and expressed as a percentage of maximal voluntary isometric contraction (%MVIC). Mean and peak electromyography amplitudes were obtained for each repetition and averaged separately across the three high-load repetitions.

Day 1 and Day 4, during the high-load bench-pull set
Number of Valid Repetitions Completed During Subsequent Free-Weight Bench-Pull Sets
大体时间:Day 1 and Day 4, beginning 3 minutes after the high-load bench-pull set

Participants completed three subsequent free-weight bench-pull sets at approximately 75% of one-repetition maximum. Each set was terminated when the mean velocity of a repetition fell below 0.65 m·s-¹ or when the participant was unable to complete the prescribed range of motion. The number of valid repetitions completed in each of the three sets was recorded.

Day 1 and Day 4, beginning 3 minutes after the high-load bench-pull set
Movement Velocity During Subsequent Free-Weight Bench-Pull Sets
大体时间:Day 1 and Day 4, beginning 3 minutes after the high-load bench-pull set

Mean and peak velocity were measured during each of the three subsequent free-weight bench-pull sets. For the repetition-matched analysis, velocity outcomes included average velocity, fastest-repetition velocity, matched-final velocity, velocity maintenance, and velocity decline. Repetition matching was performed separately for each participant and corresponding set using the smaller number of valid repetitions completed across the two experimental conditions.

Day 1 and Day 4, beginning 3 minutes after the high-load bench-pull set
Normalized Surface Electromyography Amplitude During Subsequent Free-Weight Bench-Pull Sets
大体时间:Day 1 and Day 4, beginning 3 minutes after the high-load bench-pull set

Mean and peak surface electromyography amplitudes were assessed for the right latissimus dorsi, teres major, posterior deltoid, and middle trapezius during each of the three subsequent free-weight bench-pull sets. Electromyography amplitudes were normalized to maximal voluntary isometric contraction and expressed as %MVIC. For the repetition-matched analysis, mean and peak amplitudes were averaged separately across all included repetitions within each set.

Day 1 and Day 4, beginning 3 minutes after the high-load bench-pull set

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年4月15日

初级完成 (实际的)

2026年6月30日

研究完成 (实际的)

2026年9月1日

研究注册日期

首次提交

2026年9月17日

首先提交符合 QC 标准的

2026年9月22日

首次发布 (实际的)

2026年9月29日

研究记录更新

最后更新发布 (实际的)

2026年9月29日

上次提交的符合 QC 标准的更新

2026年9月22日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

其他研究编号

  • TJUS 2025-117

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅