此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

The NUVASCULAR HARBOR Occlusion Device EU Study

2026年11月23日 更新者:Nuvascular Inc

The purpose of this study is to evaluate the safety and effectiveness of the HARBOR Occlusion Device for treating brain aneurysms. The HARBOR Device is investigational (experimental), meaning the Regulatory Authorities have not approved it for commercial use. The data collected in this research study will be used to analyze whether the HARBOR Device is safe and effective in treating brain aneurysms.

研究概览

地位

招聘中

详细说明

Nuvascular is sponsoring a prospective, multi-center, single arm clinical trial to assess the safety and effectiveness of the HARBOR Occlusion Device for the treatment of intracranial aneurysms.

研究类型

介入性

注册 (估计的)

30

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Sofia、保加利亚
        • 招聘中
        • University Hospital St. Ivan Rilski
        • 接触:
      • Salzburg、奥地利
        • 尚未招聘
        • Christian-Doppler-Klinik Salzburg / University Clinic for Neurology of the PMU / Institute for Neurointervention
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 79年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  1. Patient must be 18-79 years of age at the time of screening.

  2. Patient must have a single ruptured (defined as a patient with computed tomography (CT), magnetic resonance imaging (MRI), or lumbar puncture (LP) evidence of Subarachnoid Hemorrhage (SAH) attributed to the index aneurysm within the last 60 days) or unruptured IA requiring treatment. If the subject has an additional IA requiring treatment, the additional IA must not require treatment within 60 days of the index procedure.

  3. The index IA to be treated must have the following characteristics:

    1. Saccular in shape/morphology
    2. Equatorial width 2 mm to 12 mm
    3. Absolute neck size ≥ 4mm and < 7mm AND Dome-to-Neck (DN) ratio ≥1 OR Dome-to-Neck (DN) ratio 1 to 2
    4. IA is appropriate for treatment with the HARBOR Occlusion Device per device Instructions for Use
  4. Patient has an IA that is appropriate for treatment with HARBOR Occlusion Device without anticipated use of additional implanted devices

  5. Patient must be able to comply with all aspects of the screening, evaluation, treatment, and the post-procedure follow-up schedule.

  6. Patient or legally authorized representative must sign and date an IRB/EC-approved written informed consent prior to initiation of any study procedures.

    FOR PATIENTS WITH UNRUPTURED ANEURYSM

  7. Patient meets the criteria outlined in the "Guidelines for the Management of Patients With Unruptured Intracranial Aneurysms: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association" as published by the AHA/ASA (2015 or current version at the time of screening).

    FOR PATIENTS WITH RUPTURED ANEURYSM

  8. Patient is neurologically stable with no seizure at the onset of the SAH, not requiring External Ventricular Drain (EVD) placement prior to inclusion

  9. Patient meets the criteria outlined in the "Guidelines for the Management of Aneurysmal Subarachnoid Hemorrhage: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association" as published by the AHA/ASA (2023 or current version at the time of screening).

  10. Patient must be neurologically stable with Hunt and Hess scale (HHS) of II or less at the time of treatment

  11. Patient must be mRS < 2 prior to presentation or aneurysm rupture

Exclusion Criteria:

  1. Patient has an IA with characteristics unsuitable for endovascular treatment.
  2. Microcatheter could not reach patient's index aneurysm to allow necessary access to treat with study device.
  3. Patient has vessel characteristics, tortuosity or morphology which could preclude safe access and support during treatment with study device;
  4. Patient has vascular disease or other vascular anomaly so as to preclude the necessary access to the aneurysm for use of the study device.
  5. Patient has clinical, angiographic or CT evidence of vasospasm, vasculitis, or intracranial tumor (except small meningioma) or any other intracranial vascular malformations on presentation.
  6. Patient has conditions placing them at high risk for ischemic stroke or has exhibited ischemic symptoms such as transient ischemic attacks, minor strokes, or stroke-in-evolution within the prior 60 days.
  7. Patient has any circulatory, neurovascular, cardiovascular, or neurologic conditions that have resulted in unstable neurological symptoms.
  8. Patient has mRS > 3 prior to presentation
  9. Patient has physical, neurologic or psychiatric conditions which preclude his/her ability to comply with all aspects of the screening, evaluation, treatment, and the post-procedure follow-up schedule.
  10. Patient's index IA was previously treated.
  11. Patient has a known blood dyscrasia, coagulopathy, or hemoglobinopathy.
  12. Pregnant or breastfeeding women.
  13. Patient has known hypersensitivity, which cannot be medically treated, to any component of the study implant device (primarily nickel-titanium alloy), procedural materials, or medications commonly used during the procedure.
  14. Patient is concurrently involved in another investigational study or a post-market study that could affect the safety and effectiveness of IA treatment with the study device or with the study's follow-up schedule.
  15. Patient has an acute life-threatening illness other than the neurological disease to be treated in this trial.
  16. Patient has a life expectancy of less than 2 years due to other illness or condition (in addition to an intracranial aneurysm).

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:HARBOR Occlusion Device

Participants with eligible intracranial aneurysms will receive endovascular treatment with the HARBOR Occlusion Device. The device is delivered through a microcatheter and implanted in the target aneurysm. Participants will undergo protocol-specified clinical, neurological, and imaging assessments through the 1-year follow-up visit.

The HARBOR Occlusion Device is a self-expanding braided nitinol implant delivered through a microcatheter for endovascular treatment of intracranial aneurysms.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Complete Aneurysm Occlusion Without Retreatment, Recurrent Subarachnoid Hemorrhage, or Significant Parent Artery Stenosis.
大体时间:1 year after treatment (10-14 months)

Proportion of participants with complete aneurysm occlusion and no retreatment, recurrent subarachnoid hemorrhage, or significant parent artery stenosis (>50%) at 1 year after treatment. Participants must meet all criteria to be counted as an effectiveness success.

1 year after treatment (10-14 months)
Proportion of Participants with Nonaccidental Death Cause or Major Stroke
大体时间:From treatment through 1 year after treatment (10-14 months).

Proportion of participants with death from any nonaccidental cause or major stroke within 30 days after treatment, or major ipsilateral stroke or death due to a neurological cause from day 31 through 1 year after treatment. Major stroke is defined as an ischemic or hemorrhagic stroke resulting in an increase of at least 4 points on the NIH Stroke Scale.

From treatment through 1 year after treatment (10-14 months).

次要结果测量

结果测量
措施说明
大体时间
Angiographic Aneurysm Recurrence
大体时间:1 year after treatment (10-14 months)

Proportion of participants with angiographic aneurysm recurrence, defined as aneurysm growth or recanalization at 1 year after treatment.

1 year after treatment (10-14 months)

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年11月23日

初级完成 (估计的)

2027年12月18日

研究完成 (估计的)

2028年12月18日

研究注册日期

首次提交

2026年10月21日

首先提交符合 QC 标准的

2026年10月21日

首次发布 (实际的)

2026年10月28日

研究记录更新

最后更新发布 (实际的)

2026年11月25日

上次提交的符合 QC 标准的更新

2026年11月23日

最后验证

2026年11月1日

更多信息

与本研究相关的术语

其他研究编号

  • 2025-04
  • CIV-26-04-057507 (其他标识符:EUDAMED)

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

在美国制造并从美国出口的产品

是的

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅