Clinical Application Research Plan for Fully Automated Chemiluminescent Immunoassay Reagents

2026年11月1日 更新者:BangShun He

For the remaining serum, plasma, urine or other body fluid samples from clinical tests, chemiluminescence immunoassay reagents are used (covering eleven types of markers such as infectious diseases, tumors, hormones, thyroid function, liver fibrosis, inflammatory factors, diabetes, anemia, cardiovascular and cerebrovascular diseases, thrombotic diseases, and reproductive health). The main current platforms in this department are: Antuo (for infectious diseases, liver fibrosis, and reproductive health markers), Abbott (for tumors, diabetes, and anemia markers), Sinergy (for thyroid function, bone metabolism, and gastrointestinal function markers), Beckman (for hormones), and Norman (for infectious markers). Contents such as technology development, technology optimization, and performance evaluation of reagent items are carried out.

研究概览

详细说明

Case Selection

  1. Inclusion Criteria During the study period, based on the clinical application research protocol of the fully automated chemiluminescence immunoassay reagent, the remaining clinical test samples that met the test results or corresponding clinical diagnoses were selected, including but not limited to serum, plasma, urine, etc. Approximately 2,900 samples that met the inclusion criteria for recruitment, test data, and sample traceability information were provided.
  2. Exclusion Criteria (1) Samples that do not meet the inclusion criteria; (2) Samples with unclear clinical diagnoses; (3) Samples with severe hemolysis, deterioration, chylous blood, obvious microbial contamination, etc., which do not meet the requirements for the test.
  3. Exclusion Criteria (1) Sample results that do not meet the inclusion criteria or samples that met the exclusion criteria but still underwent testing; (2) Samples that did not complete the required tests for the complete trial or had missing data due to sample or instrument operation; (3) When the test samples underwent retesting due to human error, instrument failure, sample addition failure, etc., the retest results were taken as the standard and the reasons for retesting were recorded.
  4. Termination Criteria This study uses the remaining serum, plasma, etc. from daily tests, and no additional collection is required. It will not cause any expected harm to the subjects.

By applying the fully automated chemiluminescence immunoassay reagents developed by Xiamen Wantei Kaire Biotechnology Co., Ltd. (covering infectious diseases, tumors, hormones, thyroid function, liver fibrosis, inflammatory factors, diabetes, anemia, cardiovascular and cerebrovascular diseases, thrombotic diseases, and reproductive health and fertility, totaling eleven types of markers), the current department's main platforms are as follows: Antuo (for infectious diseases, liver fibrosis, and reproductive health and fertility markers), Abbott (for tumors, diabetes, and anemia markers), Xin Industry (for thyroid function, bone metabolism, and gastrointestinal function markers), Beckman (for hormones), and Norman (for infectious markers).

  1. Use the reagents of the above eleven series to test the remaining serum, plasma, urine or other body fluid samples from clinical tests. Compare the test results with the clinical diagnosis or the existing reagent test results in the department to evaluate indicators such as the compliance rate or quantitative correlation of the reagents, and analyze and study the differences of the same-source samples;
  2. Based on the clinical expected use, applicable population, etc. of the reagents, collect samples that meet the requirements specifically, conduct reference value research for the above eleven series of reagents, to support the clinical application of each project;
  3. Select the remaining clinical samples that meet the requirements for research and development of the above eleven series of reagents, quality control substances and control samples, etc. At the same time, match the corresponding reagents on various machines for testing, evaluate the stability, sensitivity, specificity, linear range, detection limit, precision and other indicators of the reagents, and verify the applicability of the reagents on different machines.

研究类型

观察性的

注册 (估计的)

2800

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子
  • 成人
  • 年长者

接受健康志愿者

不适用

有资格学习的性别

全部

取样方法

非概率样本

研究人群

No restrictions on audience

描述

During the study period, in accordance with the clinical application research protocol for the fully automatic chemiluminescent immunoassay reagents, clinical residual samples meeting the testing results or corresponding clinical diagnoses-such as serum, plasma, urine, and others-will be selected. Approximately 2,900 samples that meet the inclusion criteria will be provided, along with their test data and sample traceability information.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 观测模型:CASE_ONLY
  • 时间观点:PROSPECTIVE

研究衡量的是什么?

主要结果指标

结果测量
大体时间
sensitivity
大体时间:2026.11.01-2028.11.01
2026.11.01-2028.11.01

次要结果测量

结果测量
大体时间
linearity range
大体时间:2026.11.01-2028.11.01
2026.11.01-2028.11.01

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

赞助

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年11月1日

初级完成 (估计的)

2030年12月31日

研究完成 (估计的)

2030年12月31日

研究注册日期

首次提交

2026年11月1日

首先提交符合 QC 标准的

2026年11月1日

首次发布 (实际的)

2026年11月5日

研究记录更新

最后更新发布 (实际的)

2026年11月5日

上次提交的符合 QC 标准的更新

2026年11月1日

最后验证

2026年10月1日

更多信息

与本研究相关的术语

其他研究编号

  • NanjingFirst-LAB-01

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅