此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Neuroergonomic Analysis of a Brain-Computer Interface Device (BCI)

2026年11月2日 更新者:Henrique Cunha Carvalho、Universidade Federal do Paraná

Neuroergonomic Analysis of a Brain-Computer Interface (BCI) Device Based on EEG Signals and User Experience

This study evaluates the mental workload and user experience associated with a Brain-Computer Interface (BCI) device called Exobots. The Exobots system uses a non-invasive electroencephalography (EEG) headset to detect neural signals and control a robotic glove that assists hand movement. The primary goal is to assess how three different system sensitivity levels (low, medium, high) impact mental effort, usability, and overall user perception. Healthy adult volunteers (students and staff from IFPR and UFPR) will participate in a single experimental session. During the session, they will perform a repeated mental imagery task (imagine hand movement) while the EEG records their brain activity. After each sensitivity block, participants will complete standardized questionnaires (NASA Task Load Index and User Experience Questionnaire) and a semi-structured qualitative interview about their experience. By combining objective neurophysiological data with subjective feedback, this research aims to identify optimal sensitivity thresholds that minimize cognitive strain and maximize user comfort. The findings are expected to provide technical recommendations for designing more adaptive, user-centered BCI systems for future neurorehabilitation applications.

研究概览

详细说明

Background and Rationale

Brain-Computer Interfaces (BCIs) are increasingly employed in neurorehabilitation settings to assist individuals with motor impairments. While these systems enable direct neural control of assistive devices, there is a significant gap in understanding the cognitive demands they impose on users. Excessive mental workload can lead to frustration, disengagement, and suboptimal therapeutic outcomes. This study addresses this gap by applying a neuroergonomic approach-integrating objective neurophysiological measures with subjective user experience (UX) assessments.

Objectives

Primary Objective: To evaluate cognitive load during interaction with the Exobots BCI device by integrating neurophysiological metrics (EEG), psychometric UX scores, and subjective user perceptions.

Secondary Objectives:

  1. To map neural activity patterns, focusing on theta, alpha, and beta frequency bands, during BCI interaction.
  2. To correlate neurophysiological indicators of mental effort with usability and UX measures obtained via the NASA-TLX and UEQ.
  3. To identify preliminary operational sensitivity threshold parameters established during individual device calibration.
  4. To analyze participants' subjective perceptions of the physical BCI interface using a semi-structured questionnaire with open-ended questions and visual cards.
  5. To formulate technical recommendations for BCI interface design based on the integrated analysis of neurophysiological, psychometric, and qualitative data.

Study Design

This is an interventional, single-group, experimental study without a control arm. All participants will undergo the same protocol, testing three distinct sensitivity levels (low, medium, high) in a within-subjects design, with the order of sensitivity levels counterbalanced to avoid order effects.

Study Population and Sample Size

Healthy adults (aged 18 years or older) who are students (undergraduate, graduate, technical level) or staff members from the Federal University of Paraná (UFPR) and the Federal Institute of Paraná (IFPR) will be recruited.

The minimum sample size was calculated using G*Power software (version 3.1.9.7) for a bivariate normal correlation model (Exact test, Family: Correlation). Considering an expected effect size of r = 0.50, a significance level of α = 0.05, and a statistical power of (1-β) = 0.80, the calculation indicated a minimum of 29 participants. To ensure statistical robustness and account for potential data loss due to EEG artifacts or voluntary dropouts, the target enrollment is set at 30 participants, with recruitment extended to up to 60 individuals if necessary.

Intervention and Procedures

Screening and Consent: Interested individuals will receive and sign the Informed Consent Form (TCLE). A screening questionnaire will be administered to verify inclusion/exclusion criteria (e.g., no neurological disorders, no recent head injuries).

Device and Preparation: Participants will interact with the Exobots device (provided by Neurobots). An elastic cap equipped with six dry/wet EEG electrodes will be placed on the participant's scalp. A water-based conductive gel will be applied to the contact points to ensure optimal signal quality. The robotic glove will be fitted to the participant's hand.

Calibration: The system will be calibrated to recognize each participant's specific neural patterns. Based on the calibration, three distinct sensitivity thresholds (low, medium, high) will be defined and tested individually.

Experimental Protocol: Each participant will complete a sequence of repeated cycles consisting of four sequential steps:

Prepare: The participant focuses attention on their hand in anticipation of the command.

Think: The participant imagines opening/closing their hand without physically executing the movement. The EEG system detects the motor imagery signal. If the signal is maintained above the predetermined threshold for three consecutive seconds, the robotic glove is activated.

Move: The robotic glove passively moves the participant's hand. The participant is instructed to voluntarily accompany this movement if possible.

Relax: The participant stops focusing and rests for a few seconds before the next cycle.

Each sensitivity level will be tested in blocks of approximately 10 minutes, totaling approximately 35 minutes of effective interaction per participant. Sessions will be scheduled in advance, with at least 48 hours' notice.

Outcome Measures

Neurophysiological: Continuous 6-channel EEG recording throughout the task. Spectral power analysis will focus on theta (4-8 Hz), alpha (8-12 Hz), and beta (12-30 Hz) bands, with particular emphasis on the theta/beta ratio as a validated marker of cognitive load.

Psychometric: Immediately after each sensitivity block, participants will complete the NASA Task Load Index (NASA-TLX) to assess perceived mental, physical, and temporal demands, effort, and frustration. At the end of the entire session, the User Experience Questionnaire (UEQ) will be administered to evaluate pragmatic and hedonic quality attributes.

Qualitative: A semi-structured interview with open-ended questions and thematic cards will be conducted to capture nuanced perceptions regarding the physical interface, comfort, and overall experience that standardized scales may not fully address.

Statistical Analysis

Pearson correlation coefficients will be calculated to assess the association between neurophysiological metrics (e.g., theta/beta ratio, alpha power) and UX scores (UEQ and NASA-TLX). A significance level of p < 0.05 will be adopted. Qualitative data will be analyzed using content analysis techniques to identify recurring themes and insights.

Ethical Considerations

The study protocol was reviewed and approved by the Research Ethics Committee of the Federal Technological University of Paraná (CEP/UTFPR) under Approval Number 8.558.948 (issued July 2, 2026; CAAE: 97426026.1.0000.0165). All procedures comply with Brazilian regulations (Resolution CNS 466/12 and LGPD - Lei Geral de Proteção de Dados).

Participants will be informed that no direct clinical benefits are expected, but that their participation will contribute to the scientific advancement of assistive technologies. Risks are minimal and include mild scalp discomfort from the EEG cap/gel, transient fatigue, or mild frustration. Participants may take breaks or withdraw at any time without penalty. All data will be anonymized, stored on a password-protected local hard drive, and kept confidential.

Data Monitoring Committee

A formal Data Monitoring Committee (DMC) will not be established, as this is a low-risk, non-clinical, academic study with healthy volunteers and no investigational drug or device under IDE regulations.

研究类型

介入性

注册 (估计的)

30

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

学习地点

    • Paraná
      • Curitiba、Paraná、巴西、80230901
        • Federal Technological University of Paraná
        • 接触:
        • 接触:
      • Curitiba、Paraná、巴西
        • UFPR
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

是的

有资格学习的性别

全部

描述

Inclusion Criteria:

  1. Technical-level students, undergraduate students, graduate students, and staff members, of both sexes, healthy, affiliated with the Federal University of Paraná (UFPR) or the Federal Institute of Paraná (IFPR).
  2. Age 18 years or older.

Exclusion Criteria:

  1. Use of psychoactive medications.
  2. History of epilepsy or other neurological conditions that would preclude the use of the device.
  3. Severe motor limitations that prevent interaction with the device.
  4. Recent traumatic brain injuries.
  5. Injury, dermatitis, or open wound on the scalp.
  6. Excessive consumption of stimulant substances within the last 4 hours.
  7. Sleep deprivation (less than 5 hours of sleep the previous night) or extreme sleepiness on the day of data collection.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:基础科学
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Exobots BCI Device

Participants perform motor imagery tasks (imagining hand movements) while using the Exobots EEG-based BCI device. The system detects neural signals and activates a robotic glove to assist hand movement. Three distinct sensitivity thresholds (low, medium, high) are tested in a counterbalanced order within a single 35-minute experimental session.

Non-invasive electroencephalography (EEG)-based Brain-Computer Interface (BCI) system consisting of a 6-channel EEG headset and a robotic hand exoskeleton (glove). The device detects motor imagery neural signals associated with imagined hand movements. When the EEG signal is maintained above a predefined sensitivity threshold for three consecutive seconds, the system triggers the robotic glove to passively move the participant's hand. The study evaluates three distinct sensitivity levels (low, medium, high) during individual calibration. The EEG headset uses water-based conductive gel on contact points to ensure signal quality. The device is manufactured by Neurobots and provided for this research.

其他名称:
  • Exobots BCI System

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
EEG Theta/Beta Ratio as a Neurophysiological Marker of Cognitive Load
大体时间:Measured continuously during each 10-minute experimental block (blocks 1, 2, and 3) throughout the single 35-minute session.

Change in the theta/beta spectral power ratio derived from 6-channel electroencephalography (EEG) recordings during motor imagery (imagined hand movement) tasks. The theta/beta ratio is a validated neurophysiological indicator of cognitive workload and mental effort. This measure is compared across the three distinct device sensitivity levels (low, medium, high) to assess differences in cognitive demand.

Measured continuously during each 10-minute experimental block (blocks 1, 2, and 3) throughout the single 35-minute session.

次要结果测量

结果测量
措施说明
大体时间
NASA Task Load Index (NASA-TLX) Global Workload Score
大体时间:Immediately after each sensitivity block (3 times total) during the experimental session.

Subjective assessment of perceived mental workload using the NASA-TLX questionnaire. The instrument evaluates six dimensions: mental demand, physical demand, temporal demand, performance, effort, and frustration. The global workload score ranges from 0 to 100, with higher scores indicating greater perceived workload.

Immediately after each sensitivity block (3 times total) during the experimental session.
User Experience Questionnaire (UEQ) Scores
大体时间:At the end of the entire experimental session.

Assessment of user experience using the standardized User Experience Questionnaire (UEQ). The instrument measures six scales: Attractiveness, Perspicuity, Efficiency, Dependability, Stimulation, and Novelty. Each scale ranges from -3 (very negative) to +3 (very positive), with higher scores indicating a more favorable user experience.

At the end of the entire experimental session.
Qualitative Feedback on BCI Physical Interface and Overall Experience
大体时间:Immediately following the conclusion of the experimental session.

Thematic content analysis of responses collected through a semi-structured qualitative interview consisting of open-ended questions and visual thematic cards. The analysis captures nuanced perceptions regarding the physical interface (EEG cap and robotic glove), comfort, emotional engagement, usability, and suggestions for device improvement.

Immediately following the conclusion of the experimental session.
Individual Operational Sensitivity Thresholds
大体时间:During the calibration phase and across all three experimental blocks within the session.

Identification of the optimal sensitivity level (low, medium, or high) for each participant based on the calibration phase and successful device triggering during motor imagery tasks. This measure assesses how individual neural signal characteristics influence the optimal threshold for reliable BCI operation.

During the calibration phase and across all three experimental blocks within the session.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年12月28日

初级完成 (估计的)

2027年3月31日

研究完成 (估计的)

2027年3月31日

研究注册日期

首次提交

2026年11月2日

首先提交符合 QC 标准的

2026年11月2日

首次发布 (实际的)

2026年11月6日

研究记录更新

最后更新发布 (实际的)

2026年11月6日

上次提交的符合 QC 标准的更新

2026年11月2日

最后验证

2026年11月1日

更多信息

与本研究相关的术语

其他研究编号

  • 97426026.1.0000.0165

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Ethical or Consent Restrictions: Participants may not have given explicit consent for their data to be shared beyond the original study.Legal or Institutional Policies: Data sharing may be restricted by Brazillian laws.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅