Soft -Tissue Registration Accuracy With CBCT Scan of The Patient Without Scan Appliance in Comparison With Double Scan Protocol: A Comparative Study
The Registration Accuracy of Soft Tissue Surface Scan Using Intraoral Scanner With CBCT Scan of The Patient Without Scan Appliance in Comparison With Double Scan Protocol: A Comparative Study
This prospective clinical study aims to evaluate and compare the soft-tissue registration accuracy of retracted soft-tissue CBCT versus dual-scan radiographic marker protocols techniques in fully edentulous maxillae. A total of 22 completely edentulous patient cases will be evaluated to enhance optical and radiographic integration accuracy for digital prosthetic workflows.
研究概览
地位
详细说明
This prospective clinical study evaluates the precision of soft-tissue registration techniques in fully edentulous maxillae. A sample of 22 fully edentulous patient cases will undergo hard- and soft-tissue data acquisition utilizing high-resolution cone-beam computed tomography (CBCT) imaging and intraoral optical scanning protocols. The methodology investigates and compares the dimensional accuracy and surface registration of palatal vault anatomical landmarks using dual-scan radiographic markers versus direct retracted mucosal soft-tissue capture techniques. The findings aim to optimize virtual implant planning workflows and complete denture prosthodontics
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Kareem Shendy, assistant lecturer
- 电话号码:01007504223
- 邮箱:kareemshendy96@dent.asu.edu.eg
学习地点
-
-
-
Cairo、埃及
- faculty of dentistry Ain shams university
-
接触:
- Kareem Shendy, assistant lecturer
- 电话号码:01007504223
- 邮箱:kareemshendy96@dent.asu.edu.eg
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Completely edentulous maxilla opposing any type of dentition or prosthesis.
- Healthy palatal and residual alveolar ridge mucosa with no signs of active inflammation, pathological lesions, or severe anatomical irregularities.
- Patients requiring implant-supported prosthetic rehabilitation in the maxilla.
- Ability to understand and sign the informed consent form
Exclusion Criteria:
- History of previous maxillofacial surgery, trauma, or reconstructive surgery of the maxilla.
- Presence of severe palatal tori, fibrous flabby tissue, or pathological mucosal conditions affecting optical scanning or CBCT registration.
- Uncontrolled systemic diseases that could impair mucosal healing or patient cooperation
学习计划
研究是如何设计的?
设计细节
- 主要用途:诊断
- 分配:非随机化
- 介入模型:交叉作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:dual scan radiographic marker protocol
all patients will undergo dual CBCT scan protocol |
CBCT scan to the patient with scan appliance and another CBCT scan for the scan appliance alone |
|
实验性的:Retracted CBCT scan without scan appliance
CBCT with retractors without scan appliance |
Acquisition of CBCT volume without scan appliance and intraoral digital scan for soft-tissue registration comparison |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Mean registration error
大体时间:Baseline
|
compare mean regression errors between two protocols |
Baseline
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- FDASU-RecED052420
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
yes, available upon request
IPD 共享时间框架
available upon study publication and for 2 years following publication
IPD 共享访问标准
Requests directed to the corresponding author via email: data will be shared following evaluation and approval of the research proposal
IPD 共享支持信息类型
- 研究方案
- 国际碳纤维联合会
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.