Agreement Between Pleth Variability Index and Arterial Pulse Pressure Variation During Gynecological Laparoscopic Surgery
The Effect of Stepwise Trendelenburg Positioning and Pneumoperitoneum on the Agreement Between Pleth Variability Index (PVi) and Manually Calculated Invasive Pulse Pressure Variation (PPV) During Gynecological Laparoscopic Surgery: A Prospective Observational Study
This prospective observational study aims to evaluate the agreement between the non-invasive Pleth Variability Index (PVi) and manually calculated invasive Pulse Pressure Variation (PPV) during gynecological laparoscopic surgery. Measurements will be obtained at five predefined intraoperative time points corresponding to baseline supine positioning, pneumoperitoneum, 15-degree Trendelenburg positioning, 30-degree Trendelenburg positioning, and return to the supine position after desufflation. The study will assess changes in the relationship and agreement between these two hemodynamic parameters under different surgical conditions.
研究概览
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:ilke dolğun
- 电话号码:+905555485632
- 邮箱:ilkeser2004@gmail.com
学习地点
-
-
Merkez Mahallesi
-
Istanbul、Merkez Mahallesi、土耳其(türkiye)、34250
- Istinye Üniversity
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
取样方法
研究人群
The study population will consist of 45 female patients aged 18-65 years with ASA physical status I-III who are scheduled to undergo elective gynecological laparoscopic surgery, including hysterectomy, myomectomy, and gynecological oncological procedures. All participants will have clinically indicated invasive arterial monitoring, sinus rhythm, and mechanical ventilation with a fixed tidal volume of 8 mL/kg of ideal body weight. Patients meeting the predefined inclusion and exclusion criteria will be enrolled in this prospective observational study.
描述
Inclusion Criteria:
- Female patients aged 18-65 years.
- American Society of Anesthesiologists (ASA) physical status I-III.
- Scheduled for elective gynecological laparoscopic surgery, including hysterectomy, myomectomy, or gynecological oncological surgery.
- Clinically indicated invasive arterial monitoring during surgery.
- Sinus rhythm without clinically significant arrhythmias.
- Mechanical ventilation with a fixed tidal volume of 8 mL/kg of ideal body weight.
Exclusion Criteria:
- Atrial fibrillation or frequent supraventricular or ventricular premature contractions.
- Severe peripheral arterial disease or Raynaud phenomenon.
- History of open-heart surgery or severe valvular heart disease, particularly aortic regurgitation.
- Increased intracranial pressure syndrome.
- Pulmonary pathology requiring a tidal volume below 8 mL/kg.
学习计划
研究是如何设计的?
设计细节
- 观测模型:COHORT
- 时间观点:PROSPECTIVE
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Agreement Between Pleth Variability Index (PVi) and Manually Calculated Invasive Pulse Pressure Variation (PPV)
大体时间:Intraoperatively, 5 minutes after establishment of each predefined condition at T1, T2, T3, and T4.
|
Correlation coefficients and Bland-Altman bias and 95% limits of agreement between PVi and manually calculated invasive PPV will be evaluated at four intraoperative conditions: baseline supine position (T1), pneumoperitoneum in supine position (T2), pneumoperitoneum with 15-degree Trendelenburg positioning (T3), and pneumoperitoneum with 30-degree Trendelenburg positioning (T4). |
Intraoperatively, 5 minutes after establishment of each predefined condition at T1, T2, T3, and T4.
|
合作者和调查者
出版物和有用的链接
一般刊物
- Park JC, Yun SH. Analysis of Patterns of Pulse Oximeter Perfusion Index According to Postural Change During Gynecological Surgery. J Cell Mol Anesth. 2025;10(4):e162363. doi:10.5812/jcma- 162363.
- Oh C, Noh C, Baek S, Lee SY, Hong B. Comparison between conventional pleth variability index (PVI) and Rainbow PVI (RPVI) in non-cardiothoracic surgery: a retrospective study. Korean J Anesthesiol. 2025 Jul 29. doi: 10.4097/kja.25307. Online ahead of print.
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- HASEKI-PVI-PPV-2026 MASSIMO
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.