Effects of Lung Recruitment on Cerebral Hemodynamics(LRCH)
Effects of Lung Recruitment on Cerebral Hemodynamics: a Single-center, Prospective, Randomized-order, Three-period, Self-controlled Design Trial
Patients receiving invasive mechanical ventilation may develop alveolar derecruitment due to atelectasis, secretion retention, changes in body position, or acute respiratory distress syndrome. Lung recruitment maneuvers reopen partially collapsed alveoli by briefly increasing transpulmonary pressure, thereby improving lung volume and oxygenation; however, elevated airway pressure may also affect venous return, mean arterial pressure, and carbon dioxide elimination, and thus alter cerebral blood flow. Therefore, improved oxygenation does not necessarily indicate stable cerebral circulation.
At present, when selecting a lung recruitment modality in clinical practice, clinicians often rely on oxygenation response, respiratory mechanics, and operator experience, while dynamic observation of cerebral hemodynamics remains relatively insufficient. Recording only two time points before and after the maneuver may miss transient but clinically meaningful changes during pressurization, maintenance of high pressure, and recovery. Therefore, under controlled and safe conditions, it is necessary to use three commonly used clinical lung recruitment maneuvers as observational scenarios to describe cerebral hemodynamic changes during lung recruitment and to explore possible physiological factors in conjunction with cardiac output, systemic blood pressure, carbon dioxide, and respiratory mechanics. The findings are expected to provide a physiological basis for bedside cerebral perfusion monitoring and risk identification; however, short-term changes in Vm alone cannot prove that a particular maneuver is safer or improves long-term outcomes.
研究概览
地位
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Xingui Dai, PHD
- 电话号码:18175708210
- 邮箱:20685562@qq.com
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- (1)Age 18 years or older.
- (2)Receiving invasive mechanical ventilation through an endotracheal tube or tracheostomy.
- (3)A clinical indication for a lung recruitment maneuver, with an expectation that three bedside observation periods can be completed during hospitalization.
- (4)An adequate temporal acoustic window for reproducible transcranial Doppler recordings and an adequate echocardiographic window for reproducible left ventricular outflow tract velocity-time integral measurements.
- (5)Axillary temperature between 36.0°C and 37.3°C.
- (6)Written informed consent provided by the participant or a legally authorized representative.
Exclusion Criteria:
- (1)Current use of vasoactive medications.
- (2)Known severe cardiac dysfunction or severe pulmonary hypertension.
- (3)Undrained pneumothorax, marked airflow limitation, giant pulmonary bullae, or another condition associated with a high risk of barotrauma.
- (4)Known markedly elevated intracranial pressure or escalating treatment for intracranial hypertension.
- (5)Any other condition that, in the investigator's judgment, makes participation inappropriate.
学习计划
研究是如何设计的?
设计细节
- 主要用途:其他
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Sequence 1: A-B-C
A researcher who is not involved in outcome assessment will generate the randomized sequence. The three lung recruitment maneuvers will be designated A, B, and C and assigned in one of six sequences: ABC, ACB, BAC, BCA, CAB, or CBA. Consecutive observation periods will be separated by at least 12 hours. Before each period, the clinical indication for lung recruitment and the stability of vital signs will be reassessed, and the patient's position and sedation regimen will be confirmed to have remained substantially unchanged. If these conditions are not met, the period will be postponed or canceled. Any study withdrawal or early termination of a maneuver will be documented as specified above; newly enrolled participants must not be used to replace such events without reporting them. |
Before method A, original ventilator settings are kept stable for at least 10 minutes. Baseline ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) are recorded. Pressure-controlled ventilation is used with inspiratory driving pressure <=15 cmH2O, respiratory rate 16/min, I:E=1:2, and unchanged fraction of inspired oxygen (FiO2). Starting at baseline positive end-expiratory pressure (PEEP), PEEP rises by 5 cmH2O every 60 seconds to a maximum of 20 cmH2O (a smaller final increment is allowed). The same variables are recorded in the last 10 seconds of each step. After 60 seconds at PEEP 20, PEEP falls by 3 cmH2O every 60 seconds to baseline (the final decrement may vary), with measurements in each step's last 10 seconds. Original ventilator settings are restored, and measurements are repeated 60 seconds later. Before method B, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded at baseline. The ventilator will then be switched to continuous positive airway pressure (CPAP) mode, applying a constant airway pressure of 25 cmH2O for 40 seconds. The same measurements will be obtained during seconds 35-40 of the maneuver. At 40 seconds, the original clinical ventilator settings will be restored immediately. The same measurements will be repeated 40 seconds after restoration as recovery measurements. Before method C, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler ultrasonography (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded as the first set of measurements at baseline. Pressure-controlled ventilation will then be applied with positive end-expiratory pressure (PEEP) of 20 cmH2O, a set inspiratory driving pressure of no more than 15 cmH2O, a respiratory rate of 16 breaths/min, and an inspiratory-to-expiratory ratio of 1:2 for 120 seconds. The second set of the same measurements will be obtained near the end of the 120-second maneuver. The patient's original clinical ventilator settings will then be restored immediately. The third set of measurements will be obtained 60 seconds after restoration. |
|
实验性的:Sequence 2: B-C-A
A researcher who is not involved in outcome assessment will generate the randomized sequence. The three lung recruitment maneuvers will be designated A, B, and C and assigned in one of six sequences: ABC, ACB, BAC, BCA, CAB, or CBA. Consecutive observation periods will be separated by at least 12 hours. Before each period, the clinical indication for lung recruitment and the stability of vital signs will be reassessed, and the patient's position and sedation regimen will be confirmed to have remained substantially unchanged. If these conditions are not met, the period will be postponed or canceled. Any study withdrawal or early termination of a maneuver will be documented as specified above; newly enrolled participants must not be used to replace such events without reporting them. |
Before method A, original ventilator settings are kept stable for at least 10 minutes. Baseline ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) are recorded. Pressure-controlled ventilation is used with inspiratory driving pressure <=15 cmH2O, respiratory rate 16/min, I:E=1:2, and unchanged fraction of inspired oxygen (FiO2). Starting at baseline positive end-expiratory pressure (PEEP), PEEP rises by 5 cmH2O every 60 seconds to a maximum of 20 cmH2O (a smaller final increment is allowed). The same variables are recorded in the last 10 seconds of each step. After 60 seconds at PEEP 20, PEEP falls by 3 cmH2O every 60 seconds to baseline (the final decrement may vary), with measurements in each step's last 10 seconds. Original ventilator settings are restored, and measurements are repeated 60 seconds later. Before method B, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded at baseline. The ventilator will then be switched to continuous positive airway pressure (CPAP) mode, applying a constant airway pressure of 25 cmH2O for 40 seconds. The same measurements will be obtained during seconds 35-40 of the maneuver. At 40 seconds, the original clinical ventilator settings will be restored immediately. The same measurements will be repeated 40 seconds after restoration as recovery measurements. Before method C, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler ultrasonography (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded as the first set of measurements at baseline. Pressure-controlled ventilation will then be applied with positive end-expiratory pressure (PEEP) of 20 cmH2O, a set inspiratory driving pressure of no more than 15 cmH2O, a respiratory rate of 16 breaths/min, and an inspiratory-to-expiratory ratio of 1:2 for 120 seconds. The second set of the same measurements will be obtained near the end of the 120-second maneuver. The patient's original clinical ventilator settings will then be restored immediately. The third set of measurements will be obtained 60 seconds after restoration. |
|
实验性的:Sequence 3: C-A-B
A researcher who is not involved in outcome assessment will generate the randomized sequence. The three lung recruitment maneuvers will be designated A, B, and C and assigned in one of six sequences: ABC, ACB, BAC, BCA, CAB, or CBA. Consecutive observation periods will be separated by at least 12 hours. Before each period, the clinical indication for lung recruitment and the stability of vital signs will be reassessed, and the patient's position and sedation regimen will be confirmed to have remained substantially unchanged. If these conditions are not met, the period will be postponed or canceled. Any study withdrawal or early termination of a maneuver will be documented as specified above; newly enrolled participants must not be used to replace such events without reporting them. |
Before method A, original ventilator settings are kept stable for at least 10 minutes. Baseline ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) are recorded. Pressure-controlled ventilation is used with inspiratory driving pressure <=15 cmH2O, respiratory rate 16/min, I:E=1:2, and unchanged fraction of inspired oxygen (FiO2). Starting at baseline positive end-expiratory pressure (PEEP), PEEP rises by 5 cmH2O every 60 seconds to a maximum of 20 cmH2O (a smaller final increment is allowed). The same variables are recorded in the last 10 seconds of each step. After 60 seconds at PEEP 20, PEEP falls by 3 cmH2O every 60 seconds to baseline (the final decrement may vary), with measurements in each step's last 10 seconds. Original ventilator settings are restored, and measurements are repeated 60 seconds later. Before method B, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded at baseline. The ventilator will then be switched to continuous positive airway pressure (CPAP) mode, applying a constant airway pressure of 25 cmH2O for 40 seconds. The same measurements will be obtained during seconds 35-40 of the maneuver. At 40 seconds, the original clinical ventilator settings will be restored immediately. The same measurements will be repeated 40 seconds after restoration as recovery measurements. Before method C, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler ultrasonography (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded as the first set of measurements at baseline. Pressure-controlled ventilation will then be applied with positive end-expiratory pressure (PEEP) of 20 cmH2O, a set inspiratory driving pressure of no more than 15 cmH2O, a respiratory rate of 16 breaths/min, and an inspiratory-to-expiratory ratio of 1:2 for 120 seconds. The second set of the same measurements will be obtained near the end of the 120-second maneuver. The patient's original clinical ventilator settings will then be restored immediately. The third set of measurements will be obtained 60 seconds after restoration. |
|
实验性的:Sequence 1: A-C-B
A researcher who is not involved in outcome assessment will generate the randomized sequence. The three lung recruitment maneuvers will be designated A, B, and C and assigned in one of six sequences: ABC, ACB, BAC, BCA, CAB, or CBA. Consecutive observation periods will be separated by at least 12 hours. Before each period, the clinical indication for lung recruitment and the stability of vital signs will be reassessed, and the patient's position and sedation regimen will be confirmed to have remained substantially unchanged. If these conditions are not met, the period will be postponed or canceled. Any study withdrawal or early termination of a maneuver will be documented as specified above; newly enrolled participants must not be used to replace such events without reporting them. |
Before method A, original ventilator settings are kept stable for at least 10 minutes. Baseline ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) are recorded. Pressure-controlled ventilation is used with inspiratory driving pressure <=15 cmH2O, respiratory rate 16/min, I:E=1:2, and unchanged fraction of inspired oxygen (FiO2). Starting at baseline positive end-expiratory pressure (PEEP), PEEP rises by 5 cmH2O every 60 seconds to a maximum of 20 cmH2O (a smaller final increment is allowed). The same variables are recorded in the last 10 seconds of each step. After 60 seconds at PEEP 20, PEEP falls by 3 cmH2O every 60 seconds to baseline (the final decrement may vary), with measurements in each step's last 10 seconds. Original ventilator settings are restored, and measurements are repeated 60 seconds later. Before method B, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded at baseline. The ventilator will then be switched to continuous positive airway pressure (CPAP) mode, applying a constant airway pressure of 25 cmH2O for 40 seconds. The same measurements will be obtained during seconds 35-40 of the maneuver. At 40 seconds, the original clinical ventilator settings will be restored immediately. The same measurements will be repeated 40 seconds after restoration as recovery measurements. Before method C, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler ultrasonography (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded as the first set of measurements at baseline. Pressure-controlled ventilation will then be applied with positive end-expiratory pressure (PEEP) of 20 cmH2O, a set inspiratory driving pressure of no more than 15 cmH2O, a respiratory rate of 16 breaths/min, and an inspiratory-to-expiratory ratio of 1:2 for 120 seconds. The second set of the same measurements will be obtained near the end of the 120-second maneuver. The patient's original clinical ventilator settings will then be restored immediately. The third set of measurements will be obtained 60 seconds after restoration. |
|
实验性的:Sequence 1: B-A-C
A researcher who is not involved in outcome assessment will generate the randomized sequence. The three lung recruitment maneuvers will be designated A, B, and C and assigned in one of six sequences: ABC, ACB, BAC, BCA, CAB, or CBA. Consecutive observation periods will be separated by at least 12 hours. Before each period, the clinical indication for lung recruitment and the stability of vital signs will be reassessed, and the patient's position and sedation regimen will be confirmed to have remained substantially unchanged. If these conditions are not met, the period will be postponed or canceled. Any study withdrawal or early termination of a maneuver will be documented as specified above; newly enrolled participants must not be used to replace such events without reporting them. |
Before method A, original ventilator settings are kept stable for at least 10 minutes. Baseline ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) are recorded. Pressure-controlled ventilation is used with inspiratory driving pressure <=15 cmH2O, respiratory rate 16/min, I:E=1:2, and unchanged fraction of inspired oxygen (FiO2). Starting at baseline positive end-expiratory pressure (PEEP), PEEP rises by 5 cmH2O every 60 seconds to a maximum of 20 cmH2O (a smaller final increment is allowed). The same variables are recorded in the last 10 seconds of each step. After 60 seconds at PEEP 20, PEEP falls by 3 cmH2O every 60 seconds to baseline (the final decrement may vary), with measurements in each step's last 10 seconds. Original ventilator settings are restored, and measurements are repeated 60 seconds later. Before method B, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded at baseline. The ventilator will then be switched to continuous positive airway pressure (CPAP) mode, applying a constant airway pressure of 25 cmH2O for 40 seconds. The same measurements will be obtained during seconds 35-40 of the maneuver. At 40 seconds, the original clinical ventilator settings will be restored immediately. The same measurements will be repeated 40 seconds after restoration as recovery measurements. Before method C, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler ultrasonography (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded as the first set of measurements at baseline. Pressure-controlled ventilation will then be applied with positive end-expiratory pressure (PEEP) of 20 cmH2O, a set inspiratory driving pressure of no more than 15 cmH2O, a respiratory rate of 16 breaths/min, and an inspiratory-to-expiratory ratio of 1:2 for 120 seconds. The second set of the same measurements will be obtained near the end of the 120-second maneuver. The patient's original clinical ventilator settings will then be restored immediately. The third set of measurements will be obtained 60 seconds after restoration. |
|
实验性的:Sequence 1: C-B-A
A researcher who is not involved in outcome assessment will generate the randomized sequence. The three lung recruitment maneuvers will be designated A, B, and C and assigned in one of six sequences: ABC, ACB, BAC, BCA, CAB, or CBA. Consecutive observation periods will be separated by at least 12 hours. Before each period, the clinical indication for lung recruitment and the stability of vital signs will be reassessed, and the patient's position and sedation regimen will be confirmed to have remained substantially unchanged. If these conditions are not met, the period will be postponed or canceled. Any study withdrawal or early termination of a maneuver will be documented as specified above; newly enrolled participants must not be used to replace such events without reporting them. |
Before method A, original ventilator settings are kept stable for at least 10 minutes. Baseline ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) are recorded. Pressure-controlled ventilation is used with inspiratory driving pressure <=15 cmH2O, respiratory rate 16/min, I:E=1:2, and unchanged fraction of inspired oxygen (FiO2). Starting at baseline positive end-expiratory pressure (PEEP), PEEP rises by 5 cmH2O every 60 seconds to a maximum of 20 cmH2O (a smaller final increment is allowed). The same variables are recorded in the last 10 seconds of each step. After 60 seconds at PEEP 20, PEEP falls by 3 cmH2O every 60 seconds to baseline (the final decrement may vary), with measurements in each step's last 10 seconds. Original ventilator settings are restored, and measurements are repeated 60 seconds later. Before method B, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded at baseline. The ventilator will then be switched to continuous positive airway pressure (CPAP) mode, applying a constant airway pressure of 25 cmH2O for 40 seconds. The same measurements will be obtained during seconds 35-40 of the maneuver. At 40 seconds, the original clinical ventilator settings will be restored immediately. The same measurements will be repeated 40 seconds after restoration as recovery measurements. Before method C, the patient's original clinical ventilator settings will be maintained for at least 10 minutes to establish a stable baseline. Ventilator parameters, vital signs, end-tidal carbon dioxide (EtCO2), transcranial Doppler ultrasonography (TCD) parameters, and left ventricular outflow tract velocity-time integral (LVOT-VTI) will be recorded as the first set of measurements at baseline. Pressure-controlled ventilation will then be applied with positive end-expiratory pressure (PEEP) of 20 cmH2O, a set inspiratory driving pressure of no more than 15 cmH2O, a respiratory rate of 16 breaths/min, and an inspiratory-to-expiratory ratio of 1:2 for 120 seconds. The second set of the same measurements will be obtained near the end of the 120-second maneuver. The patient's original clinical ventilator settings will then be restored immediately. The third set of measurements will be obtained 60 seconds after restoration. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
mean flow velocity in the middle cerebral artery
大体时间:3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
Middle cerebral artery mean flow velocity (Vm, cm/s) will be measured using transcranial Doppler ultrasonography (TCD). In each study period, measurements will be obtained after at least 10 minutes of stable baseline ventilation. For method A, measurements will be obtained during the final 10 seconds of each 60-second PEEP step and 60 seconds after return to the original ventilation settings. For method B, measurements will be obtained at 35-40 seconds of sustained inflation and 40 seconds after return to the original settings. For method C, measurements will be obtained at baseline and 60 seconds after return to the original settings following the 120-second maneuver. No intra-maneuver TCD measurement is scheduled for method C.In the Time Frame, "return" refers to restoration of the patient's original clinical ventilator settings. |
3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Systolic blood flow velocity (Vs) of the middle cerebral artery
大体时间:3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
The Systolic blood flow velocity (Vs) of the middle cerebral artery will be measured by transcranial Doppler ultrasonography at the prespecified time points in each study period. The observed value and change from the period-specific baseline will be reported.In the Time Frame, "return" refers to restoration of the patient's original clinical ventilator settings. |
3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
|
diastolic blood flow velocity (Vd) of the middle cerebral artery
大体时间:3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
The diastolic blood flow velocity (Vd) of the middle cerebral artery will be measured by transcranial Doppler ultrasonography at the prespecified time points in each study period. The observed value and change from the period-specific baseline will be reported.In the Time Frame, "return" refers to restoration of the patient's original clinical ventilator settings. |
3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
|
pulsatility index (PI) of the middle cerebral artery
大体时间:3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
The pulsatility index (PI) of the middle cerebral artery will be measured by transcranial Doppler ultrasonography at the prespecified time points in each study period. The observed value and change from the period-specific baseline will be reported.In the Time Frame, "return" refers to restoration of the patient's original clinical ventilator settings. |
3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
|
resistance index(RI) of the middle cerebral artery
大体时间:3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
The resistance index(RI) of the middle cerebral artery will be measured by transcranial Doppler ultrasonography at the prespecified time points in each study period. The observed value and change from the period-specific baseline will be reported.In the Time Frame, "return" refers to restoration of the patient's original clinical ventilator settings. |
3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
|
Arterial partial pressure of carbon dioxide (PaCO2)
大体时间:Before and after each lung recruitment maneuver in each of up to three study periods, with at least 12 hours between periods.
|
PaCO2 (mmHg) will be measured by arterial blood gas analysis before and after each lung recruitment maneuver. The measured values and the change from the pre-maneuver value will be reported for each study period. |
Before and after each lung recruitment maneuver in each of up to three study periods, with at least 12 hours between periods.
|
|
Arterial partial pressure of oxygen (PaO2)
大体时间:Before and after each lung recruitment maneuver in each of up to three study periods, with at least 12 hours between periods.
|
PaO2 (mmHg) will be measured by arterial blood gas analysis before and after each lung recruitment maneuver. The measured values and the change from the pre-maneuver value will be reported for each study period. |
Before and after each lung recruitment maneuver in each of up to three study periods, with at least 12 hours between periods.
|
|
Arterial blood pH
大体时间:Before and after each lung recruitment maneuver in each of up to three study periods, with at least 12 hours between periods.
|
Arterial blood pH will be measured by arterial blood gas analysis before and after each lung recruitment maneuver. The measured values and the change from the pre-maneuver value will be reported for each study period. |
Before and after each lung recruitment maneuver in each of up to three study periods, with at least 12 hours between periods.
|
|
Arterial blood lactate concentration
大体时间:Before and after each lung recruitment maneuver in each of up to three study periods, with at least 12 hours between periods.
|
Arterial blood lactate concentration (mmol/L) will be measured by arterial blood gas analysis before and after each lung recruitment maneuver. The measured values and the change from the pre-maneuver value will be reported for each study period. |
Before and after each lung recruitment maneuver in each of up to three study periods, with at least 12 hours between periods.
|
|
Left ventricular outflow tract velocity-time integral (LVOT-VTI)
大体时间:3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
LVOT-VTI (cm) will be measured by Doppler echocardiography at the same prespecified time points as transcranial Doppler measurements in each study period. The measured value and its change from the period-specific pre-maneuver baseline will be reported. For method C, measurements are scheduled only at baseline and during recovery, not during the 120-second maneuver.In the Time Frame, "return" refers to restoration of the patient's original clinical ventilator settings. |
3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
|
End-tidal carbon dioxide (EtCO2)
大体时间:3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
EtCO2 (mmHg) will be monitored by capnography. A valid end-expiratory value will be recorded at the same prespecified time points as the TCD and LVOT-VTI measurements in each study period. The measured value and change from the period-specific baseline will be reported. If no valid expiratory waveform is available at a time point, the value will be recorded as missing.In the Time Frame, "return" refers to restoration of the patient's original clinical ventilator settings. |
3 periods (at least 12 hours apart): baseline; method A, final 10 seconds at each 60-second PEEP level and 60 seconds after return; method B, 35-40 seconds and 40 seconds after return; method C, near 120 seconds and 60 seconds after return.
|
合作者和调查者
调查人员
- 学习椅:Xingui Dai PhD, PHD、Chen Zhou NO.1 People's Hospital
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- LRCH-001
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 共享时间框架
Beginning 6 months after publication of the main study results and available for 3 years.
IPD 共享访问标准
Qualified researchers may submit a written request including research purpose, analysis plan, requested data elements, and data protection measures. Requests will be reviewed by the principal investigator and the institution.
IPD 共享支持信息类型
- 研究方案
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.