Randomized Assessment of SAPIEN 3 Ultra and SAPIEN 3 Ultra RESILIA Valve 23 in Patients With Severe Aortic Stenosis (REASSURE)
Randomized Assessment of SAPIEN 3 Ultra and SAPIEN 3 Ultra RESILIA Valve 23 in Patients With Severe Aortic Stenosis: Invasive Hemodynamic and Clinical Evaluation
The goal of this clinical trial is to compare two transcatheter heart valves, the SAPIEN 3 Ultra RESILIA and the SAPIEN 3 Ultra, in adults with symptomatic severe aortic stenosis (narrowing of the aortic valve) who are undergoing transcatheter aortic valve replacement (TAVR) with a 23 mm valve.
The main question it aims to answer is:
- Does the SAPIEN 3 Ultra RESILIA valve allow blood to flow more easily through the valve than the SAPIEN 3 Ultra valve after TAVR?
Researchers will compare participants who receive the SAPIEN 3 Ultra RESILIA valve with those who receive the SAPIEN 3 Ultra valve to see if there are differences in how blood flows through the valves after implantation.
Participants will be randomly assigned to receive either the SAPIEN 3 Ultra RESILIA or SAPIEN 3 Ultra valve during their clinically indicated TAVR procedure.
研究概览
地位
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Kassandra Lopez
- 电话号码:202-877-2452
- 邮箱:kassandra.lopez@medstar.net
学习地点
-
-
District of Columbia
-
Washington D.C.、District of Columbia、美国、20010
- 招聘中
- MedStar Washington Hospital Center
-
-
Maryland
-
Baltimore、Maryland、美国、21218
- 招聘中
- MedStar Union Memorial Hospital
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Subject is at least 18 years of age.
- Symptomatic severe aortic stenosis.
- Subject is judged by the institutional heart team to be appropriate for transcatheter aortic valve replacement.
- Subject has a life expectancy ≥1 year.
- Aortic annulus size is suitable for 23mm SAPIEN 3 Ultra and SAPIEN 3 Ultra RESILIA valves
- Subject is eligible for treatment with both the 23 mm SAPIEN 3 Ultra and SAPIEN 3 Ultra RESILIA valves, in accordance with the Instructions for Use.
Exclusion Criteria:
- Ongoing sepsis, including active endocarditis.
- Other medical, social, or psychological conditions that, in the opinion of the Investigator, preclude the subject from providing informed consent.
- Pregnancy or intent to become pregnant within the next 12 months.
- Contraindicated for treatment with the Edwards SAPIEN 3 Ultra and SAPIEN 3 Ultra RESILIA THV Systems in accordance with the Instructions for Use.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:SAPIEN 3 Ultra RESILIA
Participants randomized to this arm will undergo transcatheter aortic valve replacement (TAVR) with a 23-mm SAPIEN 3 Ultra RESILIA transcatheter heart valve. |
TAVR with the 23-mm SAPIEN 3 Ultra RESILIA transcatheter heart valve. |
|
有源比较器:SAPIEN 3 Ultra
Participants randomized to this arm will undergo transcatheter aortic valve replacement (TAVR) with a 23-mm SAPIEN 3 Ultra transcatheter heart valve. |
TAVR with the 23-mm SAPIEN 3 Ultra transcatheter heart valve. |
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
Invasive Aortic Valve Mean Gradient After TAVR (mmHg)
大体时间:Immediately post-TAVR (Day 0)
|
Immediately post-TAVR (Day 0)
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- REASSURE
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.