The Summer Camp Study 2: Blood Glucose Control With a Bi-Hormonal Endocrine Pancreas
2017年10月19日 更新者:Steven J. Russell, MD, PhD、Massachusetts General Hospital
The Summer Camp Study 2: Outpatient Automated Blood Glucose Control With a Bi-Hormonal Bionic Endocrine Pancreas in a Pediatric Population Ages 6-11 at the Clara Barton Diabetes Camps
This study will test the hypothesis that a wearable automated bionic pancreas system that automatically delivers both insulin and glucagon can improve glycemic control vs. usual care for young people with type 1 diabetes ages 6-11 years old in a diabetes camp environment.
調査の概要
研究の種類
介入
入学 (実際)
19
段階
- 適用できない
連絡先と場所
このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。
研究場所
-
-
Massachusetts
-
Boston、Massachusetts、アメリカ、02114
- Massachusetts General Hospital
-
-
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
6年~11年 (子)
健康ボランティアの受け入れ
いいえ
受講資格のある性別
全て
説明
Inclusion Criteria
- Age 6-11 years with type 1 diabetes for at least one year
- Diabetes managed using an insulin infusion pump for ≥ three months
- Willing to wear two infusion sets and continuous glucose monitoring (CGM) sensor and change sets frequently (at least one new glucagon infusion set daily)
- Otherwise healthy (mild chronic disease such as asthma will be allowed if well controlled that do not require medications that result in exclusion)
Exclusion Criteria
- Unable to provide informed consent, informed assent or parental consent
- Unable to comply with study procedures
- Current participation in another diabetes-related clinical trial that, in the judgment of the principal investigator, will compromise the results of this study or the safety of the subject
- End stage renal disease on dialysis (hemodialysis or peritoneal dialysis)
- Pregnancy (positive urine human chorionic gonadotropin [HCG])
- History of liver disease that is expected to interfere with the anti-hypoglycemia action of glucagon (e.g. liver failure or cirrhosis). Other liver disease (i.e. active hepatitis, steatosis, active biliary disease, any tumor of the liver, hemochromatosis, glycogen storage disease) may exclude the subject if it causes significant compromise to liver function or may do so in an unpredictable fashion
- Personal history of cystic fibrosis, pancreatitis, or other pancreatic disease, including pancreatic tumor or insulinoma
- History of prolonged QT or arrhythmia, congenital heart disease or current known cardiac disease
- Acute illness (other than non-vomiting viral illness) or exacerbation of chronic illness other than type 1 diabetes (T1D) at the time of the study
- Seizure disorder, history of any seizure within the last two years, or ongoing treatment with anticonvulsants
- Untreated or inadequately treated mental illness (indicators would include symptoms such as psychosis, hallucinations, mania, and any psychiatric hospitalization in the last year), or treatment with second generation anti-psychotic medications, which are known to affect glucose regulation.
- Electrically powered implants (e.g. cochlear implants, neurostimulators) that might be susceptible to radio-frequency (RF) interference
- Use of oral (e.g. thiazolidinediones, biguanides, sulfonylureas, glitinides, dipeptidyl peptidase 4 (DPP-4) inhibitors, sodium-glucose linked transporter 2 (SGLT-2) inhibitors) anti-diabetic medications
- History of adverse reaction to glucagon (including allergy) besides nausea and vomiting.
- Unwilling or unable to completely avoid acetaminophen during the comparator and bionic pancreas arms of the study
- History of eating disorder such as anorexia, bulimia, or diabulemia or omission of insulin to manipulate weight
- History of intentional, inappropriate administration of insulin leading to severe hypoglycemia requiring treatment
- Any factors that, in the opinion of the principal investigator, would interfere with the safe completion of the study procedures
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Bionic Pancreas
Bionic Pancreas diabetes management, a wearable bionic pancreas system that automatically delivers insulin and glucagon using a continuous glucose monitoring (CGM) device, for 5 days.
|
Automated blood glucose control via a closed-loop bionic pancreas device.
他の名前:
|
|
実験的:Usual Care
Usual Care diabetes management in a diabetes camp environment including a nurse or nursing student assigned to each cabin and review and adjustment of the insulin regimen daily by a physician or nurse practitioner, all participants using the participant's own insulin pump and a continuous glucose monitor if they use one as part of their usual care, for 5 days.
|
As a comparator control, usual diabetes camp care with the participant's own insulin pump.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Mean Continuous Glucose Monitoring Glucose (CGMG) Values During Days 2 to 5
時間枠:Days 2 to 5 of each period
|
Glucose reading were taken every 5 minutes by the CGM.
The CGM glucose results during Days 2 through 5 were averaged.
|
Days 2 to 5 of each period
|
|
Percentage of Time Spent With CGMG Concentration < 60 mg/dL During Days 2 to 5
時間枠:Days 2 to 5 of each period
|
Glucose reading were taken every 5 minutes by the CGM.
The percentage of time that the glucose concentration was less than 60 mg/dL [3.3 millimoles/liter (mmol/L)] during Days 2 through 5 was calculated.
|
Days 2 to 5 of each period
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Mean CGMG Values
時間枠:Day 1 and Days 1-5 in each period
|
Glucose reading were taken every 5 minutes by the CGM.
The glucose results for each time frame were averaged.
|
Day 1 and Days 1-5 in each period
|
|
Percentage of Time With CGMG Concentration by Ranges During Day 1
時間枠:Day 1 of each period
|
Glucose readings were taken every 5 minutes by the CGM.
The percentage of time that the glucose concentration was less than the following ranges were calculated: < 50 mg/dL(2.8
mmol/L), < 70 mg/dL (3.9 mmol/L), 70-180 mg/dL (3.9 to 10.0 mmol/L), > 180 mg/dL (10.0 mmol/L).
|
Day 1 of each period
|
|
Percentage of Time With CGMG Concentration by Ranges During Days 1 to 5
時間枠:Days 1 to 5 of each period
|
Glucose readings were taken every 5 minutes by the CGM.
The percentage of time that the glucose concentration was less than the following ranges were calculated: < 50 mg/dl (2.8 mmol/L), < 70 mg/dl (3.9 mmol/L), 70-180 mg/dl (3.9 to 10.0 mmol/L), > 180 mg/dL (10.0 mmol/L).
|
Days 1 to 5 of each period
|
|
Percentage of Time With CGMG Concentration by Ranges During Days 2 to 5
時間枠:Days 2 to 5 of each period
|
Glucose readings were taken every 5 minutes by the CGM.
The percentage of time that the glucose concentration was less than the following ranges were calculated: < 50 mg/dl (2.8 mmol/L), < 70 mg/dl (3.9 mmol/L), 70-180 mg/dl (3.9 to 10.0 mmol/L), > 180 mg/dL (10.0 mmol/L).
|
Days 2 to 5 of each period
|
|
Percentage of Participants With Mean CGMG Glucose <154 mg/dL
時間枠:Day 1, Days 1-5, and Days 2-5 of each period
|
Glucose reading were taken every 5 minutes by the CGM.
The glucose readings were averaged.
154 mg/dL was the estimated average glucose corresponding to a Hemoglobin A1C of 7.0%.
|
Day 1, Days 1-5, and Days 2-5 of each period
|
|
Percentage of Participants With Mean CGMG Glucose <169 mg/dL
時間枠:Day 1, Days 1-5, and Days 2-5 of each period
|
Glucose reading were taken every 5 minutes by the CGM.
The glucose readings were averaged.
169 mg/dL was the estimated average glucose corresponding to a Hemoglobin A1C of 7.5%.
|
Day 1, Days 1-5, and Days 2-5 of each period
|
|
Percentage of Participants With Mean CGMG Glucose <183 mg/dL
時間枠:Day 1, Days 1-5, and Days 2-5 of each period
|
Glucose reading were taken every 5 minutes by the CGM.
The glucose readings were averaged.
183 mg/dL was the estimated average glucose corresponding to a Hemoglobin A1C of 8.0%.
|
Day 1, Days 1-5, and Days 2-5 of each period
|
|
Number of CGMG Reported Hypoglycemic Events (< 70 mg/dL, < 60 mg/dL, <50 mg/dL)
時間枠:Days 1-5
|
A series of hypoglycemic measurements is defined as a single event until there is a break of ≥ 30 minutes between measurements below the defined thresholds of < 70, < 60, and <50 mg/dL.
|
Days 1-5
|
|
Mean Plasma Glucose Values
時間枠:Day 1, Days 1 to 5, and Days 2 to 5 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
The plasma glucose readings were averaged.
The plasma glucose results on Day 1, Days 1 to 5 and Days 2 to 5 were averaged.
|
Day 1, Days 1 to 5, and Days 2 to 5 of each period
|
|
Percentage of Time With Plasma Glucose Values by Ranges on Day 1
時間枠:Day 1 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
The percentage of time that the plasma glucose concentration was less than the following ranges were calculated: < 70 mg/dl (3.9 mmol/L), < 60 mg/dL (3.3 mmol/L), < 50 mg/dl (2.8 mmol/L).
|
Day 1 of each period
|
|
Percentage of Time With Plasma Glucose Values by Ranges on Days 1 to 5
時間枠:Days 1 to 5 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
The percentage of time that the plasma glucose concentration was less than the following ranges were calculated: < 70 mg/dL (3.9 mmol/L), < 60 mg/dL (3.3 mmol/L), < 50 mg/dL (2.8 mmol/L).
|
Days 1 to 5 of each period
|
|
Percentage of Time With Plasma Glucose Values by Ranges on Days 2 to 5
時間枠:Days 2 to 5 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
The percentage of time that the plasma glucose concentration was less than the following ranges were calculated: < 70 mg/dl (3.9 mmol/L), < 60 mg/dL (3.3 mmol/L), < 50 mg/dl (2.8 mmol/L).
|
Days 2 to 5 of each period
|
|
Percentage of Participants With Mean Plasma Glucose <154 mg/dL
時間枠:Day 1, Days 1 to 5, and Days 2 to 5 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
The plasma glucose readings were averaged.
154 mg/dL was the estimated average glucose corresponding to a Hemoglobin A1C of 7.0%.
|
Day 1, Days 1 to 5, and Days 2 to 5 of each period
|
|
Percentage of Participants With Mean Plasma Glucose <169 mg/dL
時間枠:Day 1, Days 1 to 5, and Days 2 to 5 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
The plasma glucose readings were averaged.
169 mg/dL was the estimated average glucose corresponding to a Hemoglobin A1C of 7.5%.
|
Day 1, Days 1 to 5, and Days 2 to 5 of each period
|
|
Percentage of Participants With Mean Plasma Glucose <183 mg/dL
時間枠:Day 1, Days 1 to 5, and Days 2 to 5 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
The plasma glucose readings were averaged.
183 mg/dL was the estimated average glucose corresponding to a Hemoglobin A1C of 8.0%.
|
Day 1, Days 1 to 5, and Days 2 to 5 of each period
|
|
Number of Plasma Glucose Reported Hypoglycemic Events (< 70 mg/dL, < 60 mg/dL, <50 mg/dL)
時間枠:Days 1-5
|
A series of hypoglycemic measurements is defined as a single event until there is a break of ≥ 30 minutes between measurements below the defined thresholds of < 70, < 60, and <50 mg/dL.
|
Days 1-5
|
|
Percentage of Days That CGM Data Was Used by Participants as Part of Their Usual Care
時間枠:Day 1, Days 1-5, and Days 2-5 of the Usual Care Period
|
The percentage of days during the Usual Care period that participants used CGM data as part of their diabetes management.
|
Day 1, Days 1-5, and Days 2-5 of the Usual Care Period
|
|
Number of Carbohydrate Interventions for Hypoglycemia When Plasma Glucose <70 mg/dL
時間枠:Day 1, Days 1-5, and Days 2-5 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
Participants were given 15 grams (g) of simple carbohydrates if their plasma glucose concentration dropped below 4.4 mmol/L.
These simple carbohydrates were counted as interventions for study outcomes if the plasma glucose concentration was less than 3.9 mmol/L.
A second intervention of 15 g of carbohydrate was given if a repeat measurement in 15-20 min was less than 3.9 mmol/L.
The total number of carbohydrate interventions are reported.
|
Day 1, Days 1-5, and Days 2-5 of each period
|
|
Grams of Carbohydrate Taken for Hypoglycemia When Plasma Glucose <70 mg/dL
時間枠:Day 1, Days 1-5, and Days 2-5 of each period
|
Fingerstick plasma glucose measurements were obtained before meals, at bedtime, at midnight, and at about 3:45 AM (six scheduled measurements).
Participants were given 15 grams (g) of simple carbohydrates if their plasma glucose concentration dropped below 4.4 mmol/L.
These simple carbohydrates were counted as interventions for study outcomes if the plasma glucose concentration was less than 3.9 mmol/L.
A second intervention of 15 g of carbohydrate was given if a repeat measurement in 15-20 min was less than 3.9 mmol/L.
|
Day 1, Days 1-5, and Days 2-5 of each period
|
|
Insulin Total Daily Dose
時間枠:11 days
|
Insulin total daily dose is reported in units per kilogram per day (U/kg/day).
|
11 days
|
|
Glucagon Total Daily Dose Levels in the Bionic Pancreas Arm
時間枠:Day 1, Days 1-5, and Days 2-5 of each period
|
Glucagon dose level is reported in micrograms per kilogram of body mass per day (µg/kg/day).
|
Day 1, Days 1-5, and Days 2-5 of each period
|
|
Daily Basal Insulin Dose in the Bionic Pancreas Period
時間枠:Day 1 through Day 5
|
The bionic pancreas automatically adapted insulin dosing to each individual's needs.
When CGM data were not available (because of sensor failure or during the warm-up time after sensor replacement), the bionic pancreas automatically delivered a dose of basal insulin based on the mean basal dosing it had calculated at that time on previous days.
Daily basal insulin dose is reported in units per kilogram (kg) per day (U/kg).
|
Day 1 through Day 5
|
|
Daily Bolus Insulin Dose in the Bionic Pancreas Period
時間枠:Day 1 through Day 5
|
The first time the bionic pancreas was used in each participant, a partial meal-priming bolus based on the participant's body mass (0.05 units/kg) was delivered.
After the first use, the size of the meal-priming bolus was adapted by the bionic pancreas to 75% of the 4-hour prandial insulin used for that meal type and size.
Daily bolus insulin dose is reported in units per kilogram (kg) per day (U/kg).
|
Day 1 through Day 5
|
|
Carbohydrate Intake
時間枠:Day 1, Days 1-5 and Days 2-5
|
Carbohydrate intake included meals, snacks and unscheduled carbohydrates administered when a participant's blood glucose was <80 mg/dl (or for symptoms at any glucose level).
Carbohydrate intake per day was averaged and is reported in grams (g) per kilogram (kg) per day (g/kg/day).
|
Day 1, Days 1-5 and Days 2-5
|
|
Number of Unscheduled Infusion Set Changes
時間枠:Day 1
|
Infusion sets for administering insulin and glucagon were placed under the skin the in the abdomen, buttocks, arms, or legs.
Infusion set changes due to pain, infusion set falling out or infusion set failure are reported.
Camp policy was to suspect failure of the infusion set whenever ketonemia occurred, so failures may not have actually been set failures, but rather failure to deliver enough insulin.
|
Day 1
|
|
Number of Unscheduled Infusion Set Changes
時間枠:Days 1-5
|
Infusion sets for administering insulin and glucagon were placed under the skin the in the abdomen, buttocks, arms, or legs.
Infusion set changes due to pain, infusion set falling out or infusion set failure are reported.
Camp policy was to suspect failure of the infusion set whenever ketonemia occurred, so failures may not have actually been set failures, but rather failure to deliver enough insulin.
|
Days 1-5
|
|
Number of Unscheduled Infusion Set Changes
時間枠:Days 2-5
|
Infusion sets for administering insulin and glucagon were placed under the skin the in the abdomen, buttocks, arms, or legs.
Infusion set changes due to pain, infusion set falling out or infusion set failure are reported.
Camp policy was to suspect failure of the infusion set whenever ketonemia occurred, so failures may not have actually been set failures, but rather failure to deliver enough insulin.
|
Days 2-5
|
|
Number of Bionic Pancreas Local Infusion Site Reactions
時間枠:Day 1, Days 1-5 and Days 2-5
|
Local infusion site reactions are defined as pain at the infusion site of the Bionic Pancreas.
Itching and redness may have also been present.
|
Day 1, Days 1-5 and Days 2-5
|
|
Mean Nausea Index Score Using a Visual Analogue Scale (VAS)
時間枠:Day 1, Days 1-5, and Days 2-5 in each period
|
Participants rated their nausea using a 0 to 10 centimeter (cm) VAS where 0=least severe nausea to 10=most severe nausea.
The average nausea index scores from Day 1 to Day 5 were calculated
|
Day 1, Days 1-5, and Days 2-5 in each period
|
|
Number of Severe Hypoglycemic Events
時間枠:Day 1, Days 1-5 and Days 2-5
|
A severe hypoglycemic event is an event where the participant is unable to self-treat and requires the assistance of another person.
|
Day 1, Days 1-5 and Days 2-5
|
|
Percentage of Time Participants Were Not Under Bionic Pancreas Control During the Bionic Pancreas Period
時間枠:5 days
|
Percentage of time that the Bionic pancreas was not functioning properly due to loss of wireless connectivity.
|
5 days
|
|
Percentage of Time Without CGM Monitoring Data
時間枠:5 days
|
Percentage of time without CGM monitoring data is the time when the participant's CGM device lost its CGM signal.
|
5 days
|
|
Change From Baseline in Body Weight
時間枠:5 days
|
The change in body weight collected at Day 5 of each period relative to Baseline.
A negative change from Baseline indicates a reduction in body weight and a positive change from Baseline indicates an increase in body weight.
|
5 days
|
|
Reliability Index
時間枠:Day 1, Days 1-5, and Days 2-5 in each period
|
Reliability index was calculated as the percentage of time values were actually recorded by CGM.
|
Day 1, Days 1-5, and Days 2-5 in each period
|
|
List of Technical Faults Associated With the Bionic Pancreas Including Cause and Resolution
時間枠:5 days
|
5 days
|
|
|
Number of Unscheduled CGM Sensor Changes
時間枠:5 days
|
The number of time a CGM sensor was replaced due to falling out or failing to report a glucose value.
|
5 days
|
|
Percentage of Participants Using a Glucagon-Like Peptide-1 (GLP-1) Agonist During the Usual Care Period
時間枠:5 days
|
The percentage of participants who used a GLP-1 agonist to manage their diabetes during the Usual Care period.
|
5 days
|
|
Percentage of Participants Using Pramlintide During the Usual Care Period
時間枠:5 days
|
The percentage of participants who used pramlintide to manage their diabetes during the Usual Care period.
|
5 days
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
出版物と役立つリンク
研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始
2014年6月1日
一次修了 (実際)
2014年8月1日
研究の完了 (実際)
2014年8月1日
試験登録日
最初に提出
2014年4月2日
QC基準を満たした最初の提出物
2014年4月2日
最初の投稿 (見積もり)
2014年4月7日
学習記録の更新
投稿された最後の更新 (実際)
2017年10月20日
QC基準を満たした最後の更新が送信されました
2017年10月19日
最終確認日
2017年10月1日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。