Flexible Endoscopy Biopsies for Submucous Tumors With a New Drill Instrument
Flexible Endoscopy Biopsies With the New Drill Biopsy Instrument for Submucous Tumors
調査の概要
詳細な説明
Background: With the existing biopsy instruments for flexible endoscopy it's only possible to achieve superficial biopsies comprising the mucosa and very seldom some small fragments of the submucosa. It is, however, increasingly important to get biopsies from the submucous tissues because the tumors that are on the increase more than any other in the stomach is the GIST (GastroIntestinal Stroma Tumours) that grows in the submucosa. Cytology is not enough for a reliable diagnosis and to often not representative. Furthermore there is a well-known risk for tract seeding when sampling through the abdominal wall with a fine needle instrument.
The investigators have invented a new biopsy instrument for flexible endoscopy that is a drill within a cylinder that can be used for biopsies of the submucous tissues, for instance GIST-tumours, see www.BIBBInstruments.com.
Hypothesis: Will it be possible to achieve representative submucous tissue from the gastrointestinal tract with the newly constructed drill biopsy instrument for flexible endoscopy. The investigators hypothesize that the amount of tissue harvested with the new drill biopsy instrument will give significantly more amount of tissue to evaluate for the pathologist than the existing biopsy forceps.
Method: Ten patients with tumours in the submucosa of the stomach are examined with a gastroscope. The investigator decides where the first biopsy should be taken and randomly the investigator blindly get the new drill instrument or the conventional biopsy forceps and take the biopsy on the decided localization. The next site of the tumour is decided and again blindly the investigator get one of the two biopsy instruments according to a previously decided scheme. Six biopsies (three with each of the two biopsy tools) in every patient are harvested in ten patients. With altogether 30 specimen for each biopsy instrument and a difference of 1/3 which is a low calculated difference 10 patients as above will give a 80 % Power (Chi-2 = 5.40, p = 0.02*). The amount of submucous tissue harvested with the two biopsy instruments are measured in microgram and as percentage of all the biopsy and compared. The quality of the specimens are also calculated.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Lund、スウェーデン、SE-22185
- Department of Surgery, Lund University
-
-
参加基準
適格基準
就学可能な年齢
- 子
- 大人
- 高齢者
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Submucous gastrointestinal tumours
Exclusion Criteria:
- No gastrointestinal submucous tumor
- Submucosal hemangioma
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:New drill biopsy instrument
To take biopsies from gastric submucosal tumors with a new drill biopsy instrument used with flexible endoscopes.
|
Biopsies taken with the new drill biopsy instrument for flexible endoscopy
他の名前:
|
|
アクティブコンパレータ:Conventional biopsy instrument
To take biopsies from gastric submucosal tumors with conventional biopsy forceps used with flexible endoscopes
|
Biopsies taken with conventional biopsy forceps for flexible endoscopic instruments
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Amount of submucous tissue in gastrointestinal submucosal tumors harvested with a new drill biopsy instrument used with flexible endoscopes.
時間枠:Within 30 days for each patient
|
Amount of submucous tissue adequate for histological examination harvested with the new drill biopsy instrument for flexible endoscopy and compared to the amount harvested with the existing biopsy forceps in a randomized setting.
|
Within 30 days for each patient
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Bruno S Walther, MD、Professor
出版物と役立つリンク
便利なリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。