このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Pilot Study for Verifying Endotracheal Tube Repositioning Using Ultrasound

2018年1月9日 更新者:Yale University

A Pilot Study to Explore Alternative Methods for Verifying Endotracheal Tube Repositioning in the Surgical Intensive Care Unit

The investigators will compare the response to oral endotracheal tube repositioning as measured by chest x-ray and measured by the air-wave device.

調査の概要

状態

終了しました

詳細な説明

Patients This prospective, non-randomized observational study will be conducted in the Surgical Intensive Care Unit (SICU) at Yale-New Haven Hospital. As this is a pilot study to determine the accuracy and precision of the SonarMed® AirWave™ monitor, the investigators have based our projected enrollment population to complete the study within one year. Intubated patients in the SICU requiring ETT repositioning will be identified by SICU clinicians (attending physicians, residents, respiratory therapists, and registered nurses). Based on manufacturer restrictions, patients with ETTs smaller than 6.5mm and larger than 9mm, double lumen ETTs, and those patients receiving Heliox therapy will be excluded from this study.

Study Procedures Once the patient is identified by a member of the clinical care team, this will be communicated to the research team.

A member of the research team will verify eligibility for the study, and then place the sensor and monitoring device into the airway circuit. The monitor is placed at the end of the endotracheal tube, in-line with the ventilator circuit.

Once the required distance for ETT repositioning is prescribed, the respiratory therapist will move the ETT based on the positioning at the incisors. This is standard practice. The device readings will be recorded pre- and post-repositioning. The therapist will be blinded to the device readings. The readings taken from the AirWave monitor are for research purposes only, and will not be considered when making clinical care decisions. Following repositioning, it is standard practice to obtain a follow up chest X-ray for confirmation of tube position within a two hour window. The same head positioning, noted on the original X-ray, will be maintained for the follow up X-ray. Device readings will also be taken at the time of the follow up X-ray. If the tube is to be further repositioned based on the decisions of the SICU team the device will be left in place until such time as the tube position has been fully optimized by the SICU team.

The ETT movement recorded by the AirWave™ monitoring device will be compared with the position change indicated on the chest X-ray. Once this has been completed, the monitor will be discontinued and removed.

For this study, additional data will be recorded: name, hospital record number, age, height, weight, gender, race, prior medical history, reason for SICU admission, reason for intubation, complications due to mechanical ventilation, days on mechanical ventilation (number of days prior to repositioning procedure and total number of days), length of stay, vital signs pre- and post-repositioning, including oxygen saturation, FiO2, and any peri-procedural vital sign abnormalities.

研究の種類

観察的

入学 (実際)

12

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Connecticut
      • New Haven、Connecticut、アメリカ、06520
        • Yale New Haven Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

Intubated patients in the SICU requiring ETT repositioning will be identified by SICU clinicians.

説明

Inclusion Criteria:

  • Intubated patients in the SICU requiring ETT repositioning will be identified by SICU clinicians.

Exclusion Criteria:

  • Based on manufacturer restrictions, patients with ETTs smaller than 6.5mm and larger than 9mm, double lumen ETTs, and those patients receiving Heliox therapy will be excluded from this study.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

この研究は何を測定していますか?

主要な結果の測定

結果測定
時間枠
Correlation between tube position measured by chest x-ray and the Air-Wave Device
時間枠:1 hour
1 hour

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • スタディチェア:Kimberly A Davis, MD, MBA、Yale School of Medicine

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2015年5月1日

一次修了 (実際)

2018年1月5日

研究の完了 (実際)

2018年1月5日

試験登録日

最初に提出

2015年3月30日

QC基準を満たした最初の提出物

2015年4月1日

最初の投稿 (見積もり)

2015年4月2日

学習記録の更新

投稿された最後の更新 (実際)

2018年1月11日

QC基準を満たした最後の更新が送信されました

2018年1月9日

最終確認日

2018年1月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • 1502015336

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

SonarMed Airwave Deviceの臨床試験

購読する