Parametric Testing of Direct Physiological Effects of Transcutaneous Vagus Nerve Stimulation (tVNS) in Healthy Controls
The purpose of this study is to determine the feasibility and safety of Transcutaneous Vagus Nerve Stimulation (tVNS) in healthy controls. Tested in healthy subjects (HS) the physiological effects of tVNS at different stimulation parameters. The electrical stimulation variables will be pulse width, frequency, and current. This will be tested in a laboratory setting and will measure tVNS effects on heart rate, respiration rate, blood pressure, and perceived pain. This is a feasibility and small safety study.
Hypothesis: tVNS is feasible and safe
調査の概要
研究の種類
入学 (実際)
段階
- フェーズ 1
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Meets none of the Exclusion Criteria
Exclusion Criteria:
- History of seizures, depression, or pain conditions
- Taking any prescription medications (excluding contraceptives and statins)
- History of any ear trauma
- History of heart conditions
- Has a heart pacemaker or artificial valve
- Has a metal implant above the waste
- Is pregnant
- Alcohol Dependence
- Illicit drug use in past 6 months
- History of brain surgery or lesions
- History of loss of consciousness (>15 min)
- Faint at the sight of blood
- Hospitalization or surgeries in past 6 months
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Active tVNS Stimulation
Stimulating electrode will be placed on left tragus of subject.
Current will be held constant (200% perceptual threshold) while pulse width and frequency are varied.The intervention used to keep current constant is Digitmer High Voltage Stimulator model DS7A TENS unit.
Each stimulation period (9 randomized stimulation parameters varying in pulse width and frequency) will last 1 minute with a 3 minute break between each parameter.
Physiological data (O2 saturation, blood pressure, breathing rate, and Electrocardiogram (EKG) to measure heart rate ) will be collected continuously.
|
|
|
偽コンパレータ:Sham tVNS Stimulation
Stimulating electrode will be placed on left ear lobe of subject for sham tVNS stimulation condition.
Current will be held constant (200% perceptual threshold) while pulse width and frequency are varied.
The intervention used to keep current constant is Digitmer High Voltage Stimulator model DS7A TENS unit.
Each stimulation period (9 randomized stimulation parameters varying in pulse width and frequency) will last 1 minute with a 3 minute break between each parameter.
Physiological data (O2 saturation, blood pressure, breathing rate, and Electrocardiogram (EKG) to measure heart rate ) will be collected continuously.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change from Baseline Heart Rate Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 1
時間枠:Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data,Electrocardiogram (EKG) to measure heart rate in beats/sec will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline Heart Rate Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 2
時間枠:Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data,Electrocardiogram (EKG) to measure heart rate in beats/sec will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline O2 Saturation Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 1
時間枠:Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data O2 saturation (% oxygen) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline O2 Saturation Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 2
時間枠:Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data O2 saturation (%oxygen) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change from Baseline Blood Pressure Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 1
時間枠:Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data Blood Pressure (mmHg) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline Blood Pressure Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 2
時間枠:Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data Blood Pressure (mmHg) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline Breathing Rate Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 1
時間枠:Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data breathing rate (%CO2) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline Breathing Rate Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 2
時間枠:Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data breathing rate (%CO2) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
協力者と研究者
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- Pro00038301
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。