- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT02835885
Parametric Testing of Direct Physiological Effects of Transcutaneous Vagus Nerve Stimulation (tVNS) in Healthy Controls
The purpose of this study is to determine the feasibility and safety of Transcutaneous Vagus Nerve Stimulation (tVNS) in healthy controls. Tested in healthy subjects (HS) the physiological effects of tVNS at different stimulation parameters. The electrical stimulation variables will be pulse width, frequency, and current. This will be tested in a laboratory setting and will measure tVNS effects on heart rate, respiration rate, blood pressure, and perceived pain. This is a feasibility and small safety study.
Hypothesis: tVNS is feasible and safe
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Effettivo)
Fase
- Fase 1
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Meets none of the Exclusion Criteria
Exclusion Criteria:
- History of seizures, depression, or pain conditions
- Taking any prescription medications (excluding contraceptives and statins)
- History of any ear trauma
- History of heart conditions
- Has a heart pacemaker or artificial valve
- Has a metal implant above the waste
- Is pregnant
- Alcohol Dependence
- Illicit drug use in past 6 months
- History of brain surgery or lesions
- History of loss of consciousness (>15 min)
- Faint at the sight of blood
- Hospitalization or surgeries in past 6 months
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione incrociata
- Mascheramento: Separare
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Active tVNS Stimulation
Stimulating electrode will be placed on left tragus of subject.
Current will be held constant (200% perceptual threshold) while pulse width and frequency are varied.The intervention used to keep current constant is Digitmer High Voltage Stimulator model DS7A TENS unit.
Each stimulation period (9 randomized stimulation parameters varying in pulse width and frequency) will last 1 minute with a 3 minute break between each parameter.
Physiological data (O2 saturation, blood pressure, breathing rate, and Electrocardiogram (EKG) to measure heart rate ) will be collected continuously.
|
|
|
Comparatore fittizio: Sham tVNS Stimulation
Stimulating electrode will be placed on left ear lobe of subject for sham tVNS stimulation condition.
Current will be held constant (200% perceptual threshold) while pulse width and frequency are varied.
The intervention used to keep current constant is Digitmer High Voltage Stimulator model DS7A TENS unit.
Each stimulation period (9 randomized stimulation parameters varying in pulse width and frequency) will last 1 minute with a 3 minute break between each parameter.
Physiological data (O2 saturation, blood pressure, breathing rate, and Electrocardiogram (EKG) to measure heart rate ) will be collected continuously.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Change from Baseline Heart Rate Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 1
Lasso di tempo: Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data,Electrocardiogram (EKG) to measure heart rate in beats/sec will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline Heart Rate Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 2
Lasso di tempo: Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data,Electrocardiogram (EKG) to measure heart rate in beats/sec will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline O2 Saturation Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 1
Lasso di tempo: Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data O2 saturation (% oxygen) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline O2 Saturation Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 2
Lasso di tempo: Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data O2 saturation (%oxygen) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Change from Baseline Blood Pressure Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 1
Lasso di tempo: Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data Blood Pressure (mmHg) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline Blood Pressure Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 2
Lasso di tempo: Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data Blood Pressure (mmHg) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline Breathing Rate Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 1
Lasso di tempo: Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data breathing rate (%CO2) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 1 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
|
Change from Baseline Breathing Rate Before Each Stimulation Period (1-9) to Post Stimulation Period (1-9) Visit 2
Lasso di tempo: Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
There are nine stimulation periods, each with own stimulation parameters that consist of a constant current, pulse width and frequency. Each stimulation period has 1 minute of stimulation (active or sham), followed by 3 minutes of post stimulation baseline recording Each of the stimulation period last 4 minutes with an additional 90 seconds between each Stimulation period. Current will be 200% of the subject's perceptual threshold for each stimulation parameter. The pulse width will be either 100 microseconds (µs), 200 µs, or 500µs. Frequency will be either 1 Hertz (Hz), 10 Hz, or 25 Hz. Baseline physiological data breathing rate (%CO2) will be collected before each stimulation parameter, during stimulation parameter, and post each stimulation parameter. |
Total time for Visit 2 (either active or sham condition) is 50 minutes - 9 Stimulation Periods (each 4 minutes long with 90 seconds between)
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
- Pro00038301
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .