Maxillary 3-implant Removable Prostheses Without Palatal Coverage on Locator Abutments
Maxillary 3-implant Removable Prostheses Without Palatal Coverage on Locator Abutments - a Prospective Cohort Study
The aims of this clinical study conducted at a dental specialty clinic in Drammen, Norway are to assess the clinical outcomes of patients with an edentate upper jaw having been treated with a removable full prosthesis supported by 3 implants to restore function and aesthetics. Clinical variables beyond implant dimensions and intraoral location, such as recall routines, maintenance needs, patient satisfaction and quality of life, will also be appraised and contrasted with an aim to elucidate their association with clinical outcomes. Specific evaluation will be done with regard to the following outcome criteria:
- crestal bone levels and periodontal conditions around implants
- incidence rates of biological, technical, traumatic failures / complications related to implants
- incidence rates of biological, technical, mechanical, esthetic failures/complications with prosthesis and prosthetic components A secondary objective is to identify the different risk factors for biological failures / complications, including the influence of medical conditions and tobacco use.
調査の概要
詳細な説明
Materials and Methods The protocol is submitted to the Research Ethics Board of the Northern Norway in order to obtain ethics approval prior to commencing the study. All patients will obtain an invitation letter detailing the objectives of the study and requested to sign a consent letter prior to clinical examinations according to principles for good research practice. All patients will be offered a free implant hygiene session and prosthesis cleaning.
Study population All patients treated in a private dental clinic in Drammen, Norway having received a maxillary removable full prosthesis supported on 3 dental implants will be invited to attend evaluations of their intra-oral status annually after implant installation and solicited about treatment satisfaction and daily oral functions. These patients were initially not offered maintenance care at the completion of their treatment.
The implants that have been used are made from titanium with a microrough surface (Astra Tech Implant System, Dentsply Implants, Mølndal, Sweden). All implants have been placed according to the manufacturer's instructions (http://www.dentsplyimplants.no/nb-NO/Implantatsystem/Prosedyrer/Treatment-planning) and fitted with precision attachments (Locator, ZEST Anchors, Escondido, CA, USA. The removable prostheses were made from heat cured poly-methyl-metacrylate (PMMA) incorporating three active matrices).
Recall Procedure Each patient will be invited by letter followed up by a phone call to attend an examination visit. The patients will complete a questionnaire related to changes in general health aspects, their experiences and satisfaction with the reconstructions and eventual need for repair sessions during the last year. Specifically, the medical history and the smoking history (e.g. pack/years) will be assessed. Recordings will be made of general and local factors which may affect the prognosis of the implants and prosthesis. This includes the occurrence of systemic disease since implant placement, regular medication used by patients, smoking status, dental treatment received since implant placement, recall frequency at the dental hygienist and the last dental examination appointment.
Collection of Data from Patients' Charts
General information will be gathered from the patients' charts. Patients' age, self-reported smoking habits and the number of cigarettes per day, medical history, medication intake, reason for tooth loss and the date of prosthesis insertion will be recorded in "patient's summary forms". Type and distribution of implants will be retrieved from patients' charts. Cases with a chart documentation of an incidence of biological or mechanical complications during the follow-up period will be closely reviewed and recorded as following:
History of implant loss (Biological complication):
Period of service before failure is traced in months for each lost implant. Lost implants will be categorized in three groups: 1) "Early Failure" which refers to implants lost before the insertion of the definite prosthesis. 2) "One-year Failure" addressing implants failed within the first year of loading. 3) "Late Failure" including implants lost more than one year following the insertion of the final prosthesis (Roos-Jansåker et al 2006).
History of peri-implant mucositis or peri-implantitis (biological complication):
Any recorded incidence of inflammation and suppuration related to the gingival tissue surrounding implants in patients' charts will be gathered and transferred to "patients' summary forms".
- History of various technical problems encountered following the insertion of the removable prosthesis (mechanical complications):
Any history of mechanical complications such as attachment loosening/fracture and incidences of cracks, chippings and fractures in resin teeth, acrylic body and prosthesis will be recorded in "patients' summary forms".
Post-operation peri-apical radiographs, taken at the day of "stage-one" surgery, will be retrieved from patient's charts and used as the reference point of supporting bone level for each implant. Reference bone levels on mesial and distal sides are determined by measuring the distance between implant platform and the most apical point of the alveolar crestal bone surrounding implant. A mean value between the mesial and distal sides is used for each implant as the reference marginal bone level.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
-
Drammen、ノルウェー、3044
- Tannlege Arild Mo
-
-
参加基準
適格基準
就学可能な年齢
- 子
- 大人
- 高齢者
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
Edentulous maxilla Competence to sign the informed consent form describing the study
Exclusion Criteria:
Lack of jaw bone for the placement of dental implants without the need for bone regeneration.
研究計画
研究はどのように設計されていますか?
デザインの詳細
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Intra-oral status
時間枠:3 years
|
The radiographic examination will comprise periapical radiographs or an orthopantomogram.
The clinical examination include a basic periodontal examination with the use of an UNC-15 (University of North Carolina) manual periodontal probe.
Outcomes measured will be presence or absence of peri-implant suppuration or fistula, the modified plaque and sulcus bleeding indices) and the probing depths.
|
3 years
|
|
Condition of prosthesis and implants
時間枠:3 years
|
The removable prosthesis will be examined for any technical flaws.
Adverse technical events include loss of retention, or fracture and/or chipping of the removable prosthesis.
Adverse mechanical events include loosening of the male attachment or fracture of an implant.
The stability of all implants will be assessed, and any sign of mobility along with pain and discomfort will be interpreted as a definitive sign of implant failure.
|
3 years
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Implant bone level changes
時間枠:3 years
|
Reference bone levels on the mesial and distal sides will be measured relative to baseline measurements made at the time of delivery of denture
|
3 years
|
|
Patient-reported satisfaction outcome
時間枠:5 years
|
A self-reported Denture Satisfaction Scale questionnaire (Allen et al. 2001).
|
5 years
|
|
Patient-reported quality of life outcome
時間枠:5 years
|
The short form version of the Oral Health Impact Profile questionnaire (OHIP-20) (Allen & Locker 2002).
|
5 years
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Asbjørn Jokstad, DDS, PhD、UiT The Arctic University of Norway
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。