Study to Evaluate the Accuracy of the New Monitor of Temperature in Comparison With the Consecrated Thermometers by Literature
COMPARATIVE STUDY BETWEEN THE USE OF THE "SPOT ON" THERMOMETER AND THE ORAL AND ESOPHAGEAL THERMOMETERS IN SPINAL AND GENERAL ANESTHESIA
調査の概要
詳細な説明
After approval by the Institutional Research Ethics Committee, the adults and pediatrics participants for elective surgeries to be submitted to general and spinal anesthesia lasting 60 minutes or more held at the surgery center at Itapecerica of Serra Hospital. The participants will receive the necessary explanations on the research and, after obtaining the responsible consent for participating in the trial, the participants will be included.
Inclusion/exclusion criteria:
Inclusion - adults and pediatrics population that will be submitted to general or spinal anesthesia in the surgery center at Itapecerica of Serra Hospital.
Exclusion:
- The participants that are feverish/present with infectious symptoms
- Refusal of the use of the device by the participants There will be select each groups made up of 70 participants. It will be submitted the adults in two groups, one submitted to general anesthesia and other group submitted to spinal anesthesia and the pediatric group to general anesthesia. The made up for the choice of the thermometer to be to general anesthesia the oral and Spot On thermometers before anesthesia induction, after anesthesia induction the Spot On, and oral, and esophageal thermometers and after surgery in PACU the Spot On and oral thermometer. In group submitted to spinal anesthesia the made up for the choice of the thermometer to be the oral and Spot On thermometers before anesthesia induction, after anesthesia induction and after surgery in PACU the Spot On and oral thermometer.
The thermometer will be used as the moment they will be identified as:
Adult General Group (AGG): the anesthetic procedure will use the spot on thermometer during the pre, intra and post-operative stages and in association with oral during the pre, intra and post-operative stages and the esophagus thermometer during the intra-operative stage.
Adult Spinal Group (ASG): the anesthetic procedure will use the oral and the spot on thermometer in the pre, intra and post-operative stages.
Pediatric General Group (ASG): the anesthetic procedure will use the oral in the pre, intra and post-operative stages and esophageal thermometers in the intra stages and the spot on thermometer during the pre, intra and post-operative stages.
The anesthetic technique will be standard according to the scheduled surgery. The study will assess the participants submitted to elective anesthesia throughout the pre, intra and post-operative stages of all scheduled elective surgeries.
All the participants for elective surgeries lasting 60 minutes or more and/or are scheduled to use any active heating device from the pre, intra and post-anesthetic stages up till the discharge from the post anesthesia recovery room.
The variables to be assessed in the study are:
- Age, gender, weight, height, physical condition according to the American Anesthesiology Association classification;
Oral, SPOT ON, and esophagus temperature measured at the following points:
- Mentrance - entering the room and every 10 min until the anesthesia induction
- Minduction - immediately before induction
- M10, M20, M30 = 10, 20, 30 min after induction and every 10 min till the end of the anesthetic procedure;
- Mpost-0, Mpost-15, Mpost-30, Mdischarge, = 0, 15, 30, and every 15 min till the discharge from post anesthesia recovery room.
- Room temperature of operating room and post anesthesia recovery room (from the participants entrance every 30 minutes to the end of the procedure and discharge to the hospital bed).
Data analysis The data will be tabulated and noted as mean and standard deviation, whenever possible, and observed for normal distribution using the Kolmogorov-Smirnov test (sample size exceeding 50). Nonparametric data will be presented by Mid and distribution boundaries. The values of temperatures are compared by estimation model of generalized equations (GEE) with Bonferroni correction (REF: Guimarães and Hirakata, 2012).
The calculation of the sample consider the participants as his own control (intragroup) and also the comparison between the equipment used (between groups, all three). Using multivariate analysis of variance (ANOVA) repeated measures, with test significance level (alpha) 1% (probability of error type I) and sample size which reduces the probability of type II error (Beta) in 95%, the sample is situated on 120 participants(Ref: Faul et al 2007).
研究の種類
入学 (予想される)
連絡先と場所
研究場所
-
-
São Paulo
-
Itapecerica da Serra、São Paulo、ブラジル、06854-000
- 募集
- Hospital Geral de Itapecerica da Serra
-
コンタクト:
- Ricardo Caio Gracco md De Bernardis
- 電話番号:5511992773523
- メール:rcaiog@yahoo.com.br
-
コンタクト:
- Ligia Andrade da Silva Telles MD Mathias
- 電話番号:5511993860059
- メール:rtimao@uol.com.br
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
The participants for elective surgeries to be submitted to general and spinal anesthesia lasting 60 minutes or more held at the central operating center at the Itapecerica da Serra Hospital.
The participants will receive the necessary explanations on the research and, after obtaining the responsible consent for participating in the trial, they will be included.
Inclusion Criteria: adults and pediatrics population that will be submitted to general or spinal anesthesia in the surgery center at Itapecerica of Serra Hospital.
Exclusion Criteria:• Patients that are feverish/present with infectious symptoms and Refusal of the use of the device by the patient
-
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Compare the Spot On with others consecrated thermometers
This study intends to compare the accuracy of the new device(SPOT ON thermometer) with the oral and esophageal in participants submitted to general and spinal anesthesia, in different types of population (pediatric and adult)
|
The made up for the choice of the thermometer to be to general anesthesia the oral and new device (Spot On thermometers) before anesthesia induction, after anesthesia induction the Spot On, and oral, and esophageal thermometers and after surgery in PACU the Spot On and oral thermometer.
In group submitted to spinal anesthesia the made up for the choice of the thermometer to be the oral and Spot On thermometers before anesthesia induction, after anesthesia induction the Spot On and oral thermometers and after surgery in PACU the Spot On and oral thermometer.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Compare the Spot On temperature and the consecrated termometer in the perioperative term.
時間枠:30 weeks
|
measure the temperature
|
30 weeks
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- Sessler DI. Temperature monitoring and perioperative thermoregulation. Anesthesiology. 2008 Aug;109(2):318-38. doi: 10.1097/ALN.0b013e31817f6d76.
- Akata T, Setoguchi H, Shirozu K, Yoshino J. Reliability of temperatures measured at standard monitoring sites as an index of brain temperature during deep hypothermic cardiopulmonary bypass conducted for thoracic aortic reconstruction. J Thorac Cardiovasc Surg. 2007 Jun;133(6):1559-65. doi: 10.1016/j.jtcvs.2006.11.031.
- Kimberger O, Thell R, Schuh M, Koch J, Sessler DI, Kurz A. Accuracy and precision of a novel non-invasive core thermometer. Br J Anaesth. 2009 Aug;103(2):226-31. doi: 10.1093/bja/aep134. Epub 2009 May 29.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (予想される)
研究の完了 (予想される)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- 56202616.9.0000.0083
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
試験データ・資料
-
研究プロトコル
情報識別子:56202616.9.0000.0083情報コメント:There you may find the project and all step to get the approval
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。