このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

E-CLAIR: Efficiency and Cost-effectiveness of Artificial Intelligence Based Diabetic Retinopathy Screening in Flanders (E-CLAIR)

2022年5月20日 更新者:JulieJacob、Universitaire Ziekenhuizen KU Leuven
To evaluate the efficiency and cost-effectiveness of an artificial intelligence based diabetic retinopathy screening program in Flanders

調査の概要

詳細な説明

The increase of diabetes patients is a 21st century global health challenge with a predicted 642 million people suffering from the disease by 2040. Diabetes mellitus is characterized by high blood sugar levels over a prolonged period of time. These uncontrolled blood sugar levels can damage the inner lining of blood vessels which on the long term causes microvascular complications that affect small blood vessels. Retinopathy is the most prevalent microvascular complication of diabetes and is caused by small blood vessel damage, and neural damage at the back layer of the eye, the retina.

Diabetic retinopathy (DR) is the leading cause of blindness and visual disability in the working population. According to a study of the Eye Diseases Prevalence Research group, 40% of adult diabetes patients in the United States have some degree of DR and 8% have vision-threatening forms of DR. In addition, the DR Barometer study indicated that many patients with diabetes do not have a regular appointment with ophthalmology for an eye examination. Risk of vision loss can be significantly decreased with annual retinal screening and detection of cases that need to be referred for follow-up and treatment. The best example showing the value of eye screening is from the United Kingdom (UK). As a result of an implementation of a nationwide screening program, DR is no longer the leading cause of irreversible blindness in the UK.

In Flanders, and in Belgium as a whole, no such well-organized, nationwide DR screening program is in place and the approach is more fragmented. Flemish guidelines for diabetes care recommend an annual visit to the ophthalmologist for all the diabetic patients who receive insulin therapy in order to check if they have DR. About 30% of the diabetics will be diagnosed for DR and 70% are disease free or in a very early stage that doesn't need further treatment. However, manual detection of DR performed by an occupied, scarce ophthalmologist is labor-intensive and expensive, causing long waiting times for the patient and possibly resulting in a lack of care when needed.

Given the extent of the diabetes population in Flanders it is self-evident that there are difficulties to screen all patients in a timely manner by ophthalmologists. Indeed, a large amount of diabetes type 2 patients do not follow the annual referral by their general practitioner (GP) and are therefore screened at a too late stage, resulting in high, avoidable costs for the patient and society. Even more, the screening of the diabetic patients by an ophthalmologist put a resource burden on our healthcare system. Task differentiation, where trained graders or GP's instead of ophthalmologists grade for referable DR, can offer a solution for the too long waiting times and the high cost. Nevertheless, manual grading of DR still is labor-intensive and costly. Even more, despite the implementation of nationwide screening programs for DR and their accompanying grading protocols, there is still substantial room for improvement in the accuracy of manual DR grading.

Recently, deep learning (DL), a form of artificial intelligence (AI), has been introduced for automated analysis of images. In a landmark paper, Gulshan and co-workers published on a deep learning algorithm with high sensitivity and specificity for detecting referable DR. This study paved the way for further developments in the field of deep learning for automated DR detection, resulting in DL models that achieve specialist-level accuracy in diagnosing DR severity. IDx, for example, obtained the first-ever FDA authorization for an AI diagnostic system in any field of medicine for DR detection.

Implementation of software for automated analysis is seen as a cost-effective solution to support decision-making in an eye screening program. In the study by Tufail et al. three different AI grading tools were retrospectively compared for their performance and cost-effectiveness in the DR screening program in the UK. In a follow-up study by Heydon et al. the most promising AI grading tool was prospectively evaluated for use in the UK screening program, demonstrating high sensitivity with a specificity that could halve the workload of the manual graders.

Despite recent research there is still an existing gap for AI to be implemented effectively and efficiently in DR screening programs. For example, the high false-positive rate of AI based results hamper the clinical workflow. Also important to note is that DL models cannot replace the breadth and contextual knowledge of human specialists. It is the case that even the most accurate models will still need to be implemented into an existing clinical workflow before they can improve patient care at all. Besides, the real-world uptake of AI applications is slow and this is partly due to a lack of convincing evidence of the economical impact.

Taken all together, renewal within diabetes care in Flanders, and more in particular further development of a more efficient DR screening pathway, is necessary to ensure that the accessibility and quality of diabetic eye care can be guaranteed at manageable costs. Flanders can undoubtedly benefit from a more efficient and cost-effective AI-assisted DR screening workflow that is at least as accurate as a human specialist. Note that the translation of study results abroad to the Flanders situation is limited. After all, one cannot simply assume that cost-effectiveness ratios from foreign economic evaluations also apply in the Flanders context. Meaning that policymakers cannot base their decisions on the possible introduction of preventive screening interventions in Flanders directly on foreign studies. These findings demonstrate the clear need to set up a specific research project in Flanders to evaluate the efficiency and cost-effectiveness of a tailor-made DR screening program in Flanders.

研究の種類

介入

入学 (予想される)

1200

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究場所

      • Antwerp、ベルギー
        • 募集
        • ZNA
        • コンタクト:
          • Pieter Paul Schauwvlieghe
      • Antwerpen、ベルギー
        • 募集
        • UZA
        • コンタクト:
          • Luc Van Os
      • Brugge、ベルギー
        • 募集
        • AZ Sint Jan
        • コンタクト:
          • Eva Vanhonsebrouck
      • Turnhout、ベルギー
        • 募集
        • AZ Turnhout
        • コンタクト:
          • Werner Dirven

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Diagnosis of diabetes mellitus
  • Age > 18 years old
  • Patient is capable of giving informed consent
  • Fluent in written and oral Dutch, or interpreter present

Exclusion Criteria:

  • - History of treatment for diabetic retinopathy or diabetic macular edema (laser or intravitreal injections)
  • Participant is contraindicated for imaging by fundus imaging systems used in the study

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:診断
  • 割り当て:ランダム化
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
アクティブコンパレータ:current workflow in Flanders
patient visits ophthalmologist
examination by ophthalmologist
アクティブコンパレータ:AI-only workflow
patient is imaged, images are interpreted by DR AI tool, only referrable cases identified by DR AI tool will visit ophthalmologist
a form of artificial intelligence (AI), has been introduced for automated analysis of images
アクティブコンパレータ:AI-human workflow
patient is imaged, images are interpreted by DR AI tool, referrable cases identified by DR AI tool will be remotely graded by a human, only the high risk patients will visit ophthalmologist
referrable cases identified by DR AI tool will be remotely graded by a human

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
sensitivity
時間枠:6 months
To evaluate the efficiency of the use of AI in screening for DRP: sensitivity
6 months
specificity
時間枠:6 months
To evaluate the efficiency of the use of AI in screening for DRP: specificity
6 months
AUC
時間枠:6 months
To evaluate the efficiency of the use of AI in screening for DRP: AUC
6 months

二次結果の測定

結果測定
メジャーの説明
時間枠
precision
時間枠:6 months
performance of three DR screening workflows: precision
6 months
decision tree model
時間枠:6 months
cost-effectiveness of three DR screening workflows: decision tree model
6 months
recall
時間枠:6 months
performance of three DR screening workflows : recall
6 months
F1 score
時間枠:6 months
performance of three DR screening workflows: F1 score
6 months
false positives and false negatives
時間枠:6 months
performance of three DR screening workflows: false positives and false negatives
6 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Julie Jacob, MD PhD、Universitaire Ziekenhuizen KU Leuven

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2021年6月17日

一次修了 (予想される)

2022年11月1日

研究の完了 (予想される)

2022年12月1日

試験登録日

最初に提出

2021年10月1日

QC基準を満たした最初の提出物

2022年5月20日

最初の投稿 (実際)

2022年5月26日

学習記録の更新

投稿された最後の更新 (実際)

2022年5月26日

QC基準を満たした最後の更新が送信されました

2022年5月20日

最終確認日

2022年5月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。