Proof-of-Concept for a Novel Optical Aperture Contact Lens in Presbyopia and Keratoconus (NOA)
The purpose of this clinical study is to evaluate the effectiveness of the NOA lens, a custom-made scleral contact lens developed by Azalea Vision BV, in improving visual quality for individuals with keratoconus and presbyopia.
This clinical study investigates a new lens design featuring a specific central aperture (opening) intended to enhance image quality by increasing depth of focus and reducing optical aberrations. The NOA lens serves as a functional prototype for future "smart lens" technology, specifically the ALMA Smart Lens. The study aims to determine if this specialized lens provides a solution for patients whose visual needs are not fully met by conventional glasses or contact lenses.
The investigation will compare a standard refractive scleral lens (Type 1) against the aperture-integrated lens (Type 2) to validate the "pinhole effect" in improving vision and reducing higher-order aberrations.
調査の概要
詳細な説明
This is a pre-market, interventional, exploratory, open-label, proof-of-concept study designed to validate the mode of action of the NOA lens, which is a freeform, rigid gas permeable (RGP) scleral contact lens customized to the unique topography of each patient's eye. The investigation serves as a functional prototype to validate the technology intended for the future ALMA Smart Lens by utilizing a specialized integrated optical aperture (pinhole) to enhance depth of focus and reduce the impact of optical aberrations.
The study primarily aims to validate this mode of action by evaluating the lens's effectiveness: for patients with keratoconus, the focus is on reducing higher-order aberrations, whereas for patients with presbyopia, the focus is on improving near visual acuity. While the primary focus is on these visual improvements, the study also evaluates the safety profile of the device by monitoring the cumulative incidence and severity of device-related safety events throughout the participation period.
The clinical process begins with a screening visit where eligibility is confirmed through medical history, visual acuity measurements, and comprehensive eye scans, including corneal topography and wavefront aberrometry. During the baseline visit, patients are fitted with the NOA lens Type 1, a scleral lens that provides standard refractive correction. After the lens has settled, investigators perform assessments of visual acuity, contrast sensitivity, visual field, and aberrometry to establish a reference standard. At the final testing visit, the process is repeated using the NOA lens Type 2, which incorporates the internally sealed optical aperture, allowing for a direct comparison of visual performance and higher-order aberrations against the baseline.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Lieselot Burggraeve
- 電話番号:+3292928071
- メール:clinical@azaleavision.com
研究場所
-
-
-
Brunssum、オランダ
- Visser Contactlenzen Brunssum
-
コンタクト:
- Korine Van Dijk, Optometrist
- 電話番号:+31 88 900 8080
- メール:NOAstudy@vissercontactlenzen.nl
-
-
-
-
-
Antwerp、ベルギー
- University Hospital Antwerp (UZA)
-
コンタクト:
- Carina Koppen, Prof. Dr.
- 電話番号:+32 3 821 32 59
- メール:Carina.Koppen@uza.be
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Age ≥ 18y at time of informed consent.
- Provide written Informed Consent.
- Being diagnosed in both eyes with:
- Keratoconus, without having presbyopia (Group A) OR: Emmetropic (+-0.5 D) presbyopia, without having corneal irregularities (Group B)
- Cornea considered to be clinically stable at the discretion of the investigator (e.g. no recent cross linking performed, no current corneal sutures, no corneal sutures recently removed).
- Willing to remove current contact lenses (any type) in both eyes for a minimum of 48 hours prior to every study visit.
- Able to read Dutch.
Exclusion Criteria:
- Active ocular infection or inflammation, including infectious keratitis, infectious conjunctivitis or blepharitis with discharge.
- Medical history (of ocular pathologies) that might lead to incomplete/incorrect eye surface scan OR wavefront aberrometry, at the discretion of the investigator.
- Use of fluorescein in the eye, within 12 hours prior to the PentacamAXL Wave scan.
- Contact lens refitting within one month prior to the screening PentacamAXL Wave scan (or planned refitting throughout the study), as this can significantly impact the corneal or scleral surface.
- Use of hybrid contact lenses or corneal RGP contact lenses within 3 months prior to (or planned use during) study participation.
- Having worn contact lenses (any type) within 48 hours prior to performing the screening Pentacam AXL Wave scan at visit 1.
- Clinically significant acute non-infectious ocular surface abnormality, including active corneal abrasion, recent ocular surface trauma.
- Severe ocular surface disease that prevents safe lens application, stable wear, or lens removal.
- Severe corneal hypoesthesia or neurotrophic keratopathy which would impair perception of pain, foreign body sensation or delay symptom reporting.
- Known hypersensitivity or allergy to the lens material or approved cleaning, disinfecting or filling solutions.
- Active allergic eye disease, including active papillary or follicular conjunctivitis.
- Systemic conditions known to impair corneal healing, such as uncontrolled autoimmune disease.
- Glaucoma.
- Central opacity and/or central corneal scarring and/or cataract.
- History of low corneal endothelial cell count (< 1500 cells/mm2) or endothelial pathologies, at the discretion of the investigator.
- Aphakic and pseudophakic.
- Severe meibomian gland dysfunction, at the discretion of the investigator.
- Known vitreoretinal pathologies, at the discretion of the investigator.
- Subjects needing eye drops every 2hrs.
- Pregnant or breastfeeding woman.
- History of other known ocular pathologies that might influence the measured endpoints of the study, at the discretion of the investigator.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:非ランダム化
- 介入モデル:順次割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Keratoconus
Keratoconus, without having presbyopia
|
Provides standard refractive correction.
It is a clear (un-printed) lens used only to design the type 2 lens by assessing on-eye centration and stability.
It also acts as the reference standard for baseline assessments in the NOA study
Incorporates an integrated optical aperture (pinhole) created by an opaque dye, in addition to standard refractive correction.
This opaque layer is printed on an internal surface and sealed within the lens cavity.
The inclusion of this optical aperture is intended to enhance depth of focus (the "pinhole effect") and reduce the impact of optical aberrations
|
|
実験的:Presbyopia
Emmetropic (+-0.5 D) presbyopia, without having corneal irregularities
|
Provides standard refractive correction.
It is a clear (un-printed) lens used only to design the type 2 lens by assessing on-eye centration and stability.
It also acts as the reference standard for baseline assessments in the NOA study
Incorporates an integrated optical aperture (pinhole) created by an opaque dye, in addition to standard refractive correction.
This opaque layer is printed on an internal surface and sealed within the lens cavity.
The inclusion of this optical aperture is intended to enhance depth of focus (the "pinhole effect") and reduce the impact of optical aberrations
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Mode of action NOA lens in keratoconus group
時間枠:As assessed at the final study visit 3 (=approximately 6 weeks after baseline) compared to the baseline visit 2 (=day 0 + approximately 6 weeks)
|
Change from baseline in higher-order aberrations (HOAs), as measured by a wavefront aberrometer and expressed as the total root mean square (RMS) wavefront error, following a single evaluation session with the NOA lens type 2.
|
As assessed at the final study visit 3 (=approximately 6 weeks after baseline) compared to the baseline visit 2 (=day 0 + approximately 6 weeks)
|
|
Mode of action NOA lens in presbyopia group
時間枠:As assessed at the final study visit 3 (=approximately 6 weeks after baseline) compared to the baseline visit 2 (=day 0 + approximately 6 weeks)
|
Change from baseline in near visual acuity, as measured by a logMAR chart, following a single evaluation session with the NOA lens type 2.
|
As assessed at the final study visit 3 (=approximately 6 weeks after baseline) compared to the baseline visit 2 (=day 0 + approximately 6 weeks)
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Safety of NOA lens
時間枠:as from screening visit 1 (day 0) until study completion, which takes place on average 12 weeks after the screening visit.
|
Cumulative incidence and severity of device-related safety events throughout the study, in both groups
|
as from screening visit 1 (day 0) until study completion, which takes place on average 12 weeks after the screening visit.
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Koppen、University Hospital, Antwerp
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- Az02
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。