このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Estimation of Fetal Weight by Measuring Abdominal Circumference, Abdominal Subcutaneous Soft Tissue Thickness, Femur Length and Mid-thigh Soft Tissue Thickness

2026年5月7日 更新者:Khaled Mustafa Attyia、Assiut University

Estimation of Fetal Weight by Measuring Abdominal Circumference, Abdominal Subcutaneous Soft Tissue Thickness, Femur Length and Mid-thigh Soft Tissue Thickness: Cross Sectional Study.

Traditional methods for estimating fetal weight (EFW) often miss the mark because they focus on bone and circumference while ignoring fetal fat. This study proposes a more inclusive formula to fix that. Current models (using BPD, HC, AC, and FL) are the standard but suffer from high observer variability. These formulas struggle at the extremes (macrosomia or growth restriction) and fail to account for fetal adiposity, which makes up 10-12% of a newborn's mass. The study introduces a novel formula that moves beyond simple bone measurements by integrating Soft Tissue Thickness (STT). By accounting for a broader range of biological variants and fat distribution, this new model aims to provide a non-inferior, more precise predictive value for fetal weight compared to traditional methods.

調査の概要

詳細な説明

Accurate estimation of fetal weight (EFW) is fundamental to modern obstetric management. Traditional sonographic biometry-utilizing biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL)-is the standard for predictive modeling. However, these parameters are limited by significant inter- and intra-observer variability and a loss of precision at the extremes of fetal weight, such as in cases of macrosomia or growth restriction. Furthermore, conventional formulas often fail to account for fetal adiposity, which constitutes 10-12% of total neonatal body mass. Recent literature suggests that the integration of soft tissue thickness (STT) measurements-specifically mid-arm, subscapular, abdominal subcutaneous, and mid-thigh thickness-can enhance the accuracy of EFW. While the Scioscia and modified Scioscia formulas rely exclusively on FL and mid-thigh measurements, this study proposes a novel, multi-parametric approach. By combining AC, fetal abdominal subcutaneous tissue thickness, FL, and mid-thigh soft tissue thickness, we hypothesize that our formula offers a non-inferior predictive value. This model accounts for a broader range of biological variants and soft tissue distribution patterns that significantly influence overall fetal mass.

Detailed history (maternal age, obstetric history, medical history, previous macrosomic fetuses, previous shoulder dystocia). Gestational age is calculated from the first day of the last menstrual period and confirmed by either a first- or second-trimester ultrasound scan. When the ultrasound-determined gestational age differed from that calculated from the last menstrual period by >7 days in the first trimester, or by >10 days in the second trimester, the ultrasound-determined gestational age is used.

The study will be bi-phasic, 1st phase is model development phase in which we develop a mathematical model for fetal weight estimation incorporating (abdominal circumference, fetal abdominal subcutaneous soft tissue thickness, femur length, mid-thigh soft tissue thickness), the 2nd phase is a validation and comparison phase in which we test our model and compare it to modified Scioscia formula and conventional Hadlock formula.

For measurement of femur length (FL) Each caliper is placed at the ends of the ossified diaphysis without including the distal femoral epiphysis if it is visible.

For the measurement of AC, the transverse section of the fetal abdomen should be as circular as possible, and the fetal spine preferably in the 3- or 9-o'clock position, umbilical vein at the level of the portal sinus, stomach visible and kidneys not visible. The AC is measured directly at the outer surface of the skin line, with ellipse calipers.

Mid-thigh STT: measured linearly in the standard longitudinal section used for FL measurement. In the middle third of the fetal thigh, with the femur lying parallel to the transducer, mid-thigh STT was measured from the outer margin of the skin to the outer margin of the femur shaft. The measurement was taken, providing that the greater and the lesser trochanter are turned upwards. This section assures the correct view of the lateral side of the femur (vastus lateralis, which is the biggest part of the quadriceps femoris) Abdominal Subcutaneous STT: Measured at the level of the AC plane, anterior 1/3rd of abdominal circumference between outer and inner edges of abdominal wall by ultrasound.

Actual birth weight (AFW) was immediately measured after delivery by a neonatologist using digital medical neonatal scale.

研究の種類

観察的

入学 (推定)

300

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

はい

サンプリング方法

非確率サンプル

調査対象母集団

full term pregnant women within 48-72 hours before delivery

説明

Inclusion Criteria:

  1. Singleton Gestation.
  2. Gestational Age: Participants must be at a term ≥ 37 weeks
  3. Timing of Examination: Sonographic EFW must be performed within 48 -72 hours prior to delivery.
  4. Welling to share in the study.

Exclusion Criteria:

  1. Fetal Anomalies.
  2. Amniotic Fluid Disorders: oligohydramnios or polyhydramnios
  3. Maternal morbid obesity (BMI > 40 kg/m2)
  4. Maternal medical disorders: as diabetes, hypertension, systemic lupus erythromatosis or others affecting fetal growth
  5. Fetal Hydrops
  6. Fetal Malpresentation
  7. Fetal growth restriction

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
Full term pregnant women
full term pregnant women with in 48-72 hours of delivery either cesarean section, spontaneous vaginal delivery or induced vaginal delivery.
ultrasound examination of full-term pregnant women with 48-72 hours of delivery measuring Abdominal circumference, fetal abdominal subcutaneous soft tissue thickness, femur length and mid-thigh soft tissue thickness.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
development and validation of novel method for fetal weight estimation
時間枠:within 48- 72 hours of delivery
a novel module for fetal weight estimation depending on abdominal circumference, fetal abdominal subcutaneous soft tissue thickness, femur length, mid-thigh soft tissue thickness.
within 48- 72 hours of delivery

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年7月1日

一次修了 (推定)

2027年12月30日

研究の完了 (推定)

2028年7月30日

試験登録日

最初に提出

2026年5月4日

QC基準を満たした最初の提出物

2026年5月4日

最初の投稿 (実際)

2026年5月8日

学習記録の更新

投稿された最後の更新 (実際)

2026年5月12日

QC基準を満たした最後の更新が送信されました

2026年5月7日

最終確認日

2026年5月1日

詳しくは

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する