Cerebral Microembolization During Transcatheter Aortic Valve Implantation: Comparing Balloon-expandable and Self-expanding Valves (MICROTAVI)
Cerebral Microembolization During Transcatheter Aortic Valve Implantation: A Randomized Study Comparing Balloon-expandable and Self-expanding Valves
This study will compare the amount of cerebral microembolization during transcatheter aortic valve implantation (TAVI) between two commonly used types of transcatheter aortic valves: balloon-expandable valves and self-expanding valves.
Cerebral microembolization refers to small particles or material that may travel to the brain during the procedure. These signals can be detected using transcranial Doppler ultrasound, a non-invasive method for monitoring blood flow in the brain. Although clinically apparent stroke after TAVI is relatively uncommon, small silent brain lesions may occur, and their mechanisms are not fully understood.
Adult patients with severe symptomatic aortic valve stenosis who are scheduled for TAVI will be included. Participants will be randomly assigned to receive either a balloon-expandable or a self-expanding valve, both of which are established and routinely used treatment options. Transcranial Doppler monitoring will be performed before, during, and after the procedure to record the number of microembolic signals. The study will also record neurological events and procedural characteristics, such as procedure duration and the need for balloon dilatation.
The aim of the study is to determine whether the type of valve is associated with a different burden of cerebral microembolization during TAVI. The results may help improve understanding of procedural factors related to cerebral embolization and may support future strategies for reducing neurological risk in patients undergoing TAVI.
調査の概要
状態
条件
詳細な説明
This is a prospective, randomized, parallel-group clinical study designed to compare cerebral microembolization during transcatheter aortic valve implantation between balloon-expandable and self-expanding transcatheter aortic valves.
The study will be conducted at University Hospital Dubrava and Sisters of Charity Hospital (Zagreb) with an expected duration of one year. Adult patients aged 18 years or older with severe symptomatic aortic valve stenosis and an indication for transcatheter aortic valve implantation will be considered for participation.
Eligible participants will be randomized using a computer-generated randomization sequence into one of two study groups according to the type of implanted valve: a balloon-expandable valve or a self-expanding valve. Both valve types represent standard, widely accepted therapeutic options in contemporary clinical practice. The study does not introduce a new or insufficiently tested technology, and participation will not change the standard course of treatment or expose patients to additional risk beyond that normally associated with the procedure.
All participants will undergo a standard TAVI procedure with periprocedural anticoagulation according to current clinical guidelines. Cerebral microembolization will be assessed using transcranial Doppler ultrasound. Monitoring will be performed immediately before the procedure, during the procedure, and after the procedure. The presence and number of microembolic signals will be recorded, including analysis across specific procedural phases such as instrumentation, valvuloplasty, valve implantation, and the post-implantation period.
The primary outcome will be the difference in the change in the number of microembolic signals between the balloon-expandable and self-expanding valve groups. Secondary outcomes will include the change in microembolic signal burden within each group, the distribution of microembolic signals across procedural phases, the occurrence of new microembolic signals after the procedure, the incidence of clinical neurological events, and the association between procedural characteristics and microembolic signal burden.
Collected data will include demographic and clinical characteristics, such as age, sex, and comorbidities, as well as procedural data including procedure duration, vascular access route, need for predilatation or postdilatation, and procedural complications. Data will be analyzed using appropriate statistical methods for between-group and within-group comparisons, depending on data distribution.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Mihovil Santini, MD
- 電話番号:+385958101778
- メール:023miho@gmail.com
研究連絡先のバックアップ
- 名前:Zeljković, PhD,MD
- 電話番号:+385917823289
- メール:ivanzeljkov@gmail.com
研究場所
-
-
-
Zagreb、クロアチア、10000
- UH Dubrava
-
Zagreb、クロアチア、10000
- Sisters of Charity Hospital Zagreb
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Age 18 years or older
- Severe symptomatic aortic valve stenosis
- Clinical indication for transcatheter aortic valve implantation
- Feasibility of transcranial Doppler ultrasound monitoring
- Signed written informed consent
Exclusion Criteria:
- Recent stroke or transient ischemic attack
- Significant cerebrovascular disease preventing reliable transcranial Doppler -assessment
- Previous aortic valve implantation
- Active endocarditis
- Pregnancy or breastfeeding
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Balloon-Expandable Valve
Participants in this arm will undergo transcatheter aortic valve implantation using a balloon-expandable transcatheter aortic valve.
This valve type is a standard and routinely used treatment option for patients with severe symptomatic aortic valve stenosis.
Cerebral microembolization will be assessed by transcranial Doppler ultrasound before, during, and after the procedure.
|
A balloon-expandable transcatheter aortic valve will be implanted during a standard transcatheter aortic valve implantation procedure in participants randomized to this intervention arm.
This valve type is an established and routinely used treatment option for severe symptomatic aortic valve stenosis.
Cerebral microembolization will be monitored using transcranial Doppler ultrasound before, during, and after the procedure.
|
|
アクティブコンパレータ:Self-Expanding Valve
articipants in this arm will undergo transcatheter aortic valve implantation using a self-expanding transcatheter aortic valve.
This valve type is a standard and routinely used treatment option for patients with severe symptomatic aortic valve stenosis.
Cerebral microembolization will be assessed by transcranial Doppler ultrasound before, during, and after the procedure.
|
A self-expanding transcatheter aortic valve will be implanted during a standard transcatheter aortic valve implantation procedure in participants randomized to this intervention arm.
This valve type is an established and routinely used treatment option for severe symptomatic aortic valve stenosis.
Cerebral microembolization will be monitored using transcranial Doppler ultrasound before, during, and after the procedure.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in Number of Cerebral Microembolic Signals During TAVI
時間枠:Before, during, and immediately after the TAVI procedure
|
he primary outcome is the difference between study groups in the change in the number of cerebral microembolic signals detected by transcranial Doppler ultrasound before, during, and after transcatheter aortic valve implantation.
The comparison will be made between participants receiving balloon-expandable valves and those receiving self-expanding valves.
|
Before, during, and immediately after the TAVI procedure
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Number of Cerebral Microembolic Signals Within Each Study Group
時間枠:Before, during, and immediately after the TAVI procedure
|
Change in the number of cerebral microembolic signals detected by transcranial Doppler ultrasound before, during, and after TAVI will be assessed separately within each valve group.
|
Before, during, and immediately after the TAVI procedure
|
|
Distribution of Cerebral Microembolic Signals by Procedural Phase
時間枠:During the TAVI procedure and immediately after valve implantation
|
The number of cerebral microembolic signals will be analyzed according to procedural phase, including instrumentation, valvuloplasty, valve implantation, and the post-implantation period.
|
During the TAVI procedure and immediately after valve implantation
|
|
Occurrence of New Cerebral Microembolic Signals After TAVI
時間枠:Immediately after the TAVI procedure
|
he occurrence and number of new cerebral microembolic signals detected after completion of the TAVI procedure will be recorded and compared between the study groups.
|
Immediately after the TAVI procedure
|
|
Incidence of Clinical Neurological Events
時間枠:Periprocedural
|
The association between procedural characteristics, including procedure duration, vascular access route, predilatation, postdilatation, and procedural complications, and the number of cerebral microembolic signals will be assessed.
|
Periprocedural
|
|
Correlation Between Procedure Duration and Cerebral Microembolic Signal Burden
時間枠:Periprocedural
|
The correlation between procedure duration, measured in minutes, and cerebral microembolic signal burden, measured as the number of cerebral microembolic signals detected by transcranial Doppler monitoring, will be assessed.
|
Periprocedural
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 2026/0423-10
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。