Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Cerebral Microembolization During Transcatheter Aortic Valve Implantation: Comparing Balloon-expandable and Self-expanding Valves (MICROTAVI)

21 maj 2026 uppdaterad av: Ivan Zeljkovic

Cerebral Microembolization During Transcatheter Aortic Valve Implantation: A Randomized Study Comparing Balloon-expandable and Self-expanding Valves

This study will compare the amount of cerebral microembolization during transcatheter aortic valve implantation (TAVI) between two commonly used types of transcatheter aortic valves: balloon-expandable valves and self-expanding valves.

Cerebral microembolization refers to small particles or material that may travel to the brain during the procedure. These signals can be detected using transcranial Doppler ultrasound, a non-invasive method for monitoring blood flow in the brain. Although clinically apparent stroke after TAVI is relatively uncommon, small silent brain lesions may occur, and their mechanisms are not fully understood.

Adult patients with severe symptomatic aortic valve stenosis who are scheduled for TAVI will be included. Participants will be randomly assigned to receive either a balloon-expandable or a self-expanding valve, both of which are established and routinely used treatment options. Transcranial Doppler monitoring will be performed before, during, and after the procedure to record the number of microembolic signals. The study will also record neurological events and procedural characteristics, such as procedure duration and the need for balloon dilatation.

The aim of the study is to determine whether the type of valve is associated with a different burden of cerebral microembolization during TAVI. The results may help improve understanding of procedural factors related to cerebral embolization and may support future strategies for reducing neurological risk in patients undergoing TAVI.

Studieöversikt

Detaljerad beskrivning

This is a prospective, randomized, parallel-group clinical study designed to compare cerebral microembolization during transcatheter aortic valve implantation between balloon-expandable and self-expanding transcatheter aortic valves.

The study will be conducted at University Hospital Dubrava and Sisters of Charity Hospital (Zagreb) with an expected duration of one year. Adult patients aged 18 years or older with severe symptomatic aortic valve stenosis and an indication for transcatheter aortic valve implantation will be considered for participation.

Eligible participants will be randomized using a computer-generated randomization sequence into one of two study groups according to the type of implanted valve: a balloon-expandable valve or a self-expanding valve. Both valve types represent standard, widely accepted therapeutic options in contemporary clinical practice. The study does not introduce a new or insufficiently tested technology, and participation will not change the standard course of treatment or expose patients to additional risk beyond that normally associated with the procedure.

All participants will undergo a standard TAVI procedure with periprocedural anticoagulation according to current clinical guidelines. Cerebral microembolization will be assessed using transcranial Doppler ultrasound. Monitoring will be performed immediately before the procedure, during the procedure, and after the procedure. The presence and number of microembolic signals will be recorded, including analysis across specific procedural phases such as instrumentation, valvuloplasty, valve implantation, and the post-implantation period.

The primary outcome will be the difference in the change in the number of microembolic signals between the balloon-expandable and self-expanding valve groups. Secondary outcomes will include the change in microembolic signal burden within each group, the distribution of microembolic signals across procedural phases, the occurrence of new microembolic signals after the procedure, the incidence of clinical neurological events, and the association between procedural characteristics and microembolic signal burden.

Collected data will include demographic and clinical characteristics, such as age, sex, and comorbidities, as well as procedural data including procedure duration, vascular access route, need for predilatation or postdilatation, and procedural complications. Data will be analyzed using appropriate statistical methods for between-group and within-group comparisons, depending on data distribution.

Studietyp

Interventionell

Inskrivning (Beräknad)

80

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

Studera Kontakt Backup

Studieorter

      • Zagreb, Kroatien, 10000
        • UH Dubrava
      • Zagreb, Kroatien, 10000
        • Sisters of Charity Hospital Zagreb

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Nej

Beskrivning

Inclusion Criteria:

  • Age 18 years or older
  • Severe symptomatic aortic valve stenosis
  • Clinical indication for transcatheter aortic valve implantation
  • Feasibility of transcranial Doppler ultrasound monitoring
  • Signed written informed consent

Exclusion Criteria:

  • Recent stroke or transient ischemic attack
  • Significant cerebrovascular disease preventing reliable transcranial Doppler -assessment
  • Previous aortic valve implantation
  • Active endocarditis
  • Pregnancy or breastfeeding

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Behandling
  • Tilldelning: Randomiserad
  • Interventionsmodell: Parallellt uppdrag
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Aktiv komparator: Balloon-Expandable Valve
Participants in this arm will undergo transcatheter aortic valve implantation using a balloon-expandable transcatheter aortic valve. This valve type is a standard and routinely used treatment option for patients with severe symptomatic aortic valve stenosis. Cerebral microembolization will be assessed by transcranial Doppler ultrasound before, during, and after the procedure.
A balloon-expandable transcatheter aortic valve will be implanted during a standard transcatheter aortic valve implantation procedure in participants randomized to this intervention arm. This valve type is an established and routinely used treatment option for severe symptomatic aortic valve stenosis. Cerebral microembolization will be monitored using transcranial Doppler ultrasound before, during, and after the procedure.
Aktiv komparator: Self-Expanding Valve
articipants in this arm will undergo transcatheter aortic valve implantation using a self-expanding transcatheter aortic valve. This valve type is a standard and routinely used treatment option for patients with severe symptomatic aortic valve stenosis. Cerebral microembolization will be assessed by transcranial Doppler ultrasound before, during, and after the procedure.
A self-expanding transcatheter aortic valve will be implanted during a standard transcatheter aortic valve implantation procedure in participants randomized to this intervention arm. This valve type is an established and routinely used treatment option for severe symptomatic aortic valve stenosis. Cerebral microembolization will be monitored using transcranial Doppler ultrasound before, during, and after the procedure.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Change in Number of Cerebral Microembolic Signals During TAVI
Tidsram: Before, during, and immediately after the TAVI procedure
he primary outcome is the difference between study groups in the change in the number of cerebral microembolic signals detected by transcranial Doppler ultrasound before, during, and after transcatheter aortic valve implantation. The comparison will be made between participants receiving balloon-expandable valves and those receiving self-expanding valves.
Before, during, and immediately after the TAVI procedure

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Number of Cerebral Microembolic Signals Within Each Study Group
Tidsram: Before, during, and immediately after the TAVI procedure
Change in the number of cerebral microembolic signals detected by transcranial Doppler ultrasound before, during, and after TAVI will be assessed separately within each valve group.
Before, during, and immediately after the TAVI procedure
Distribution of Cerebral Microembolic Signals by Procedural Phase
Tidsram: During the TAVI procedure and immediately after valve implantation
The number of cerebral microembolic signals will be analyzed according to procedural phase, including instrumentation, valvuloplasty, valve implantation, and the post-implantation period.
During the TAVI procedure and immediately after valve implantation
Occurrence of New Cerebral Microembolic Signals After TAVI
Tidsram: Immediately after the TAVI procedure
he occurrence and number of new cerebral microembolic signals detected after completion of the TAVI procedure will be recorded and compared between the study groups.
Immediately after the TAVI procedure
Incidence of Clinical Neurological Events
Tidsram: Periprocedural
The association between procedural characteristics, including procedure duration, vascular access route, predilatation, postdilatation, and procedural complications, and the number of cerebral microembolic signals will be assessed.
Periprocedural
Correlation Between Procedure Duration and Cerebral Microembolic Signal Burden
Tidsram: Periprocedural
The correlation between procedure duration, measured in minutes, and cerebral microembolic signal burden, measured as the number of cerebral microembolic signals detected by transcranial Doppler monitoring, will be assessed.
Periprocedural

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

1 juni 2026

Primärt slutförande (Beräknad)

30 januari 2027

Avslutad studie (Beräknad)

1 februari 2027

Studieregistreringsdatum

Först inskickad

16 maj 2026

Först inskickad som uppfyllde QC-kriterierna

21 maj 2026

Första postat (Faktisk)

29 maj 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

29 maj 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

21 maj 2026

Senast verifierad

1 maj 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera