Continuous Glucose Monitoring Alerts, Accuracy, and Patient Outcomes in Adults With Inherited Metabolic Disorders
Continuous Glucose Monitoring Alerts, Accuracy, and Patient Outcomes in Adults With Inherited Metabolic Disorders Prone to Hypoglycemia
The goal of this clinical trial is to learn if a continuous glucose monitor (CGM) with predictive alerts works better than a CGM with standard alerts to prevent low blood sugar (hypoglycemia) in adults with inherited metabolic disorders (IMDs), such as glycogen storage disorders (GSDs) and congenital hyperinsulinism (CH).
The main questions it aims to answer are:
Does a CGM with predictive alerts lower the time spent with low blood sugar compared to a CGM with standard alerts? Do participants feel better and behave differently when using a CGM with predictive alerts? How accurate are the two CGM devices in this group of people? Researchers will compare two CGM devices - Dexcom G7 (with predictive and standard alerts) and Dexcom ONE+ (with standard alerts only) - to see if predictive alerts help reduce low blood sugar episodes and improve quality of life.
Participants will:
Wear each CGM device for 30 days Have a 30-day break between the two devices Check blood sugar levels and record food intake Complete questionnaires about their experience with each device
調査の概要
状態
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Padova
-
Padova、Padova、イタリア、35128
- University Hospital Of Padova
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Age 18 years or older
- Genetic or biochemical diagnosis of Glycogen Storage Disease (GSD) or Congenital Hyperinsulinism (CH)
- At least one clinical and biochemical follow-up at the hospital outpatient service within the last one or two years
- Ability to sign informed consent and comply with study procedures
Exclusion Criteria:
- Inability to sign informed consent or comply with study procedures
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:支持療法
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Dexcom G7 (Threshold + Predictive Alerts)
|
The Dexcom G7 is a CE-marked continuous glucose monitoring (CGM) device worn for 30 days.
It provides real-time interstitial glucose readings every 5 minutes.
The device offers both threshold-based alerts, activated when glucose levels fall below or rise above pre-set values, and predictive alerts, activated when glucose levels are predicted to reach a threshold within 20 minutes.
The low glucose alert threshold was set at 70 mg/dL for all participants.
|
|
アクティブコンパレータ:Dexcom ONE+ (Threshold-Only Alerts)
|
The Dexcom ONE+ is a CE-marked continuous glucose monitoring (CGM) device worn for 30 days.
It provides real-time interstitial glucose readings every 5 minutes.
The device offers threshold-based alerts only, activated when glucose levels fall below or rise above pre-set values, without predictive alert functionality.
The low glucose alert threshold was set at 70 mg/dL for all participants.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Time Below Range (TBR)
時間枠:30 days per device (total study duration: approximately 90 days including washout period)
|
Percentage of time spent with interstitial glucose levels below 70 mg/dL, as measured by continuous glucose monitoring (CGM). TBR is reported at two thresholds: TBR1 (54-69 mg/dL) and TBR2 (<54 mg/dL), both expressed as percentage of monitoring time (%), over 30 days for each device. Unit of Measure: % of monitoring time |
30 days per device (total study duration: approximately 90 days including washout period)
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Time in Range (TIR)
時間枠:Time Frame: 30 days per device
|
Percentage of time spent with interstitial glucose levels within the target range of 70-140 mg/dL, as measured by CGM over 30 days for each device. Expressed as percentage of monitoring time (%). Unit of Measure: % of monitoring time |
Time Frame: 30 days per device
|
|
Time Above Range (TAR)
時間枠:Time Frame: 30 days per device
|
Percentage of time spent with interstitial glucose levels above 140 mg/dL, as measured by CGM over 30 days for each device. Expressed as percentage of monitoring time (%). Unit of Measure: % of monitoring time |
Time Frame: 30 days per device
|
|
Mean Glucose Level
時間枠:Time Frame: 30 days per device
|
Mean interstitial glucose levels calculated over 24 hours and during nighttime (00:00-07:00), as measured by CGM over 30 days for each device. Unit of Measure: mg/dL |
Time Frame: 30 days per device
|
|
Sensor Accuracy - median absolute relative difference (MARD)
時間枠:30 days per device
|
Accuracy of CGM readings compared to capillary blood glucose reference values (Accu-Check Instant, Roche), expressed as Median Absolute Relative Difference (MARD). Capillary and CGM values matched within a ±5-minute time window. Unit of Measure: % |
30 days per device
|
|
Dietary Intake Assessment
時間枠:7 days per device
|
Total daily energy intake measured during each device wear period Unit of Measure: kcal/day Total daily macronutrient intake measured during each device wear period Unit of Measure: grams/day Daily uncooked cornstarch intake measured during each device wear period Unit of Measure: grams/day All dietary intakes were assessed by 7-day food diary analyzed with Metadieta® software (Meteda Srl, Italy), completed during CGM monitoring and reviewed by an experienced metabolic dietitian.
|
7 days per device
|
|
Hypoglycemia Fear and Protective Behaviors Assessment
時間枠:baseline and after 30 days per device
|
Assessed using the Hypoglycemia Fear Survey (HFS), comprising two subscales: Worry (HFS-W) and Behavior (HFS-B). Each item scored 0-4; total range 0-132; higher scores indicate greater fear of hypoglycemia and more behaviors engaged to avoid hypoglycemic episodes. Unit of Measure: Score (0-132) |
baseline and after 30 days per device
|
|
Hypoglycemia Awareness Assessment
時間枠:baseline and after 30 days per device
|
Assessed using the Clarke Hypoglycemia Awareness Questionnaire (CHAQ), comprising 8 items on hypoglycemia awareness and recognition. Range 0-7; scores ≥4 indicate impaired awareness of hypoglycemia; higher scores indicate worse hypoglycemia awareness. Unit of Measure: Score (0-7) |
baseline and after 30 days per device
|
|
Sleep Quality Assessment
時間枠:Baseline and after 30 days per device
|
assessed using the Pittsburgh Sleep Quality Index (PSQI), a self-report questionnaire assessing sleep quality and disturbances over the previous month. Global score ranges from 0 to 21; scores >5 indicate poor sleep quality; higher scores indicate worse sleep quality. Unit of Measure: Score (0-21) |
Baseline and after 30 days per device
|
|
Health-Related Quality of Life Assessment
時間枠:Baseline and after 30 days per device
|
Assessed using the 12-Item Short Form Health Survey (SF-12), yielding Physical Component Summary (PCS) and Mental Component Summary (MCS) standardized scores. Higher scores indicate better quality of life. Unit of Measure: Standardized score for Italian population |
Baseline and after 30 days per device
|
|
Body Mass Index (BMI)
時間枠:Baseline and after 30 days per device
|
Height measured at baseline; weight measured at the start and end of each CGM period using a calibrated mechanical scale (Seca 700). BMI calculated as weight (kg)/height² (m²), interpreted according to WHO classification: <18.5 underweight; 18.5-25 healthy weight; 25-30 overweight; >30 obesity. Unit of Measure: kg/m² |
Baseline and after 30 days per device
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- Gugelmo G, Maines E, Boscari F, Lenzini L, Fadini GP, Burlina A, Avogaro A, Vitturi N. Continuous glucose monitoring in patients with inherited metabolic disorders at risk for Hypoglycemia and Nutritional implications. Rev Endocr Metab Disord. 2024 Oct;25(5):897-910. doi: 10.1007/s11154-024-09903-y. Epub 2024 Oct 1.
- Rossi A, Venema A, Haarsma P, Feldbrugge L, Burghard R, Rodriguez-Buritica D, Parenti G, Oosterveer MH, Derks TGJ. A Prospective Study on Continuous Glucose Monitoring in Glycogen Storage Disease Type Ia: Toward Glycemic Targets. J Clin Endocrinol Metab. 2022 Aug 18;107(9):e3612-e3623. doi: 10.1210/clinem/dgac411.
- Overduin RJ, Venema A, Lubout CMA, Fokkert-Wilts MJ, De Boer F, Schreuder AB, Rossi A, Derks TGJ. Continuous glucose monitoring metrics in people with liver glycogen storage disease and idiopathic ketotic hypoglycemia: A single-center, retrospective, observational study. Mol Genet Metab. 2024 Sep-Oct;143(1-2):108573. doi: 10.1016/j.ymgme.2024.108573. Epub 2024 Aug 30.
- Peeks F, Hoogeveen IJ, Feldbrugge RL, Burghard R, de Boer F, Fokkert-Wilts MJ, van der Klauw MM, Oosterveer MH, Derks TGJ. A retrospective in-depth analysis of continuous glucose monitoring datasets for patients with hepatic glycogen storage disease: Recommended outcome parameters for glucose management. J Inherit Metab Dis. 2021 Sep;44(5):1136-1150. doi: 10.1002/jimd.12383. Epub 2021 May 5.
- Ferreira CR, Rahman S, Keller M, Zschocke J; ICIMD Advisory Group. An international classification of inherited metabolic disorders (ICIMD). J Inherit Metab Dis. 2021 Jan;44(1):164-177. doi: 10.1002/jimd.12348.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- CET 6104/AO/24, URC AOP3544
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。