Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Continuous Glucose Monitoring Alerts, Accuracy, and Patient Outcomes in Adults With Inherited Metabolic Disorders

21. Mai 2026 aktualisiert von: Nicola Vitturi, University Hospital Padova

Continuous Glucose Monitoring Alerts, Accuracy, and Patient Outcomes in Adults With Inherited Metabolic Disorders Prone to Hypoglycemia

The goal of this clinical trial is to learn if a continuous glucose monitor (CGM) with predictive alerts works better than a CGM with standard alerts to prevent low blood sugar (hypoglycemia) in adults with inherited metabolic disorders (IMDs), such as glycogen storage disorders (GSDs) and congenital hyperinsulinism (CH).

The main questions it aims to answer are:

Does a CGM with predictive alerts lower the time spent with low blood sugar compared to a CGM with standard alerts? Do participants feel better and behave differently when using a CGM with predictive alerts? How accurate are the two CGM devices in this group of people? Researchers will compare two CGM devices - Dexcom G7 (with predictive and standard alerts) and Dexcom ONE+ (with standard alerts only) - to see if predictive alerts help reduce low blood sugar episodes and improve quality of life.

Participants will:

Wear each CGM device for 30 days Have a 30-day break between the two devices Check blood sugar levels and record food intake Complete questionnaires about their experience with each device

Studienübersicht

Studientyp

Interventionell

Einschreibung (Tatsächlich)

11

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Padova
      • Padova, Padova, Italien, 35128
        • University Hospital Of Padova

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  • Age 18 years or older
  • Genetic or biochemical diagnosis of Glycogen Storage Disease (GSD) or Congenital Hyperinsulinism (CH)
  • At least one clinical and biochemical follow-up at the hospital outpatient service within the last one or two years
  • Ability to sign informed consent and comply with study procedures

Exclusion Criteria:

  • Inability to sign informed consent or comply with study procedures

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Unterstützende Pflege
  • Zuteilung: Zufällig
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: Dexcom G7 (Threshold + Predictive Alerts)
The Dexcom G7 is a CE-marked continuous glucose monitoring (CGM) device worn for 30 days. It provides real-time interstitial glucose readings every 5 minutes. The device offers both threshold-based alerts, activated when glucose levels fall below or rise above pre-set values, and predictive alerts, activated when glucose levels are predicted to reach a threshold within 20 minutes. The low glucose alert threshold was set at 70 mg/dL for all participants.
Aktiver Komparator: Dexcom ONE+ (Threshold-Only Alerts)
The Dexcom ONE+ is a CE-marked continuous glucose monitoring (CGM) device worn for 30 days. It provides real-time interstitial glucose readings every 5 minutes. The device offers threshold-based alerts only, activated when glucose levels fall below or rise above pre-set values, without predictive alert functionality. The low glucose alert threshold was set at 70 mg/dL for all participants.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Time Below Range (TBR)
Zeitfenster: 30 days per device (total study duration: approximately 90 days including washout period)

Percentage of time spent with interstitial glucose levels below 70 mg/dL, as measured by continuous glucose monitoring (CGM). TBR is reported at two thresholds: TBR1 (54-69 mg/dL) and TBR2 (<54 mg/dL), both expressed as percentage of monitoring time (%), over 30 days for each device.

Unit of Measure: % of monitoring time

30 days per device (total study duration: approximately 90 days including washout period)

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Time in Range (TIR)
Zeitfenster: Time Frame: 30 days per device

Percentage of time spent with interstitial glucose levels within the target range of 70-140 mg/dL, as measured by CGM over 30 days for each device. Expressed as percentage of monitoring time (%).

Unit of Measure: % of monitoring time

Time Frame: 30 days per device
Time Above Range (TAR)
Zeitfenster: Time Frame: 30 days per device

Percentage of time spent with interstitial glucose levels above 140 mg/dL, as measured by CGM over 30 days for each device. Expressed as percentage of monitoring time (%).

Unit of Measure: % of monitoring time

Time Frame: 30 days per device
Mean Glucose Level
Zeitfenster: Time Frame: 30 days per device

Mean interstitial glucose levels calculated over 24 hours and during nighttime (00:00-07:00), as measured by CGM over 30 days for each device.

Unit of Measure: mg/dL

Time Frame: 30 days per device
Sensor Accuracy - median absolute relative difference (MARD)
Zeitfenster: 30 days per device

Accuracy of CGM readings compared to capillary blood glucose reference values (Accu-Check Instant, Roche), expressed as Median Absolute Relative Difference (MARD). Capillary and CGM values matched within a ±5-minute time window.

Unit of Measure: %

30 days per device
Dietary Intake Assessment
Zeitfenster: 7 days per device
Total daily energy intake measured during each device wear period Unit of Measure: kcal/day Total daily macronutrient intake measured during each device wear period Unit of Measure: grams/day Daily uncooked cornstarch intake measured during each device wear period Unit of Measure: grams/day All dietary intakes were assessed by 7-day food diary analyzed with Metadieta® software (Meteda Srl, Italy), completed during CGM monitoring and reviewed by an experienced metabolic dietitian.
7 days per device
Hypoglycemia Fear and Protective Behaviors Assessment
Zeitfenster: baseline and after 30 days per device

Assessed using the Hypoglycemia Fear Survey (HFS), comprising two subscales: Worry (HFS-W) and Behavior (HFS-B). Each item scored 0-4; total range 0-132; higher scores indicate greater fear of hypoglycemia and more behaviors engaged to avoid hypoglycemic episodes.

Unit of Measure: Score (0-132)

baseline and after 30 days per device
Hypoglycemia Awareness Assessment
Zeitfenster: baseline and after 30 days per device

Assessed using the Clarke Hypoglycemia Awareness Questionnaire (CHAQ), comprising 8 items on hypoglycemia awareness and recognition. Range 0-7; scores ≥4 indicate impaired awareness of hypoglycemia; higher scores indicate worse hypoglycemia awareness.

Unit of Measure: Score (0-7)

baseline and after 30 days per device
Sleep Quality Assessment
Zeitfenster: Baseline and after 30 days per device

assessed using the Pittsburgh Sleep Quality Index (PSQI), a self-report questionnaire assessing sleep quality and disturbances over the previous month. Global score ranges from 0 to 21; scores >5 indicate poor sleep quality; higher scores indicate worse sleep quality.

Unit of Measure: Score (0-21)

Baseline and after 30 days per device
Health-Related Quality of Life Assessment
Zeitfenster: Baseline and after 30 days per device

Assessed using the 12-Item Short Form Health Survey (SF-12), yielding Physical Component Summary (PCS) and Mental Component Summary (MCS) standardized scores. Higher scores indicate better quality of life.

Unit of Measure: Standardized score for Italian population

Baseline and after 30 days per device
Body Mass Index (BMI)
Zeitfenster: Baseline and after 30 days per device

Height measured at baseline; weight measured at the start and end of each CGM period using a calibrated mechanical scale (Seca 700). BMI calculated as weight (kg)/height² (m²), interpreted according to WHO classification: <18.5 underweight; 18.5-25 healthy weight; 25-30 overweight; >30 obesity.

Unit of Measure: kg/m²

Baseline and after 30 days per device

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Allgemeine Veröffentlichungen

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

8. Januar 2025

Primärer Abschluss (Tatsächlich)

31. Juli 2025

Studienabschluss (Tatsächlich)

30. September 2025

Studienanmeldedaten

Zuerst eingereicht

15. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

21. Mai 2026

Zuerst gepostet (Tatsächlich)

29. Mai 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

29. Mai 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

21. Mai 2026

Zuletzt verifiziert

1. Mai 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren