このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Multimodal mAgnetic Resonance imaGIng in Cardiovascular Disease (MAGIC)

Multimodal-MRI in Cardiovascular Diseases

This single-center, prospective, observational cohort study aims to evaluate the clinical application value of multi-modal cardiovascular magnetic resonance (CMR) imaging in patients with cardiovascular diseases (CVD).

While traditional imaging methods have limitations in fully evaluating myocardial tissue characteristics, multi-modal CMR offers a comprehensive, non-invasive "one-stop" assessment. It can simultaneously evaluate heart structure, function, tissue features (such as fibrosis and edema), and hemodynamics.

The study plans to enroll patients with suspected or confirmed CVD. Participants will undergo a comprehensive multi-modal CMR scan (including Cine, T1/T2 mapping, Late Gadolinium Enhancement, and 4D flow sequences) as part of their evaluation. In addition to clinical evaluation, the study will explore sequence optimization (e.g., comparing pre-contrast vs. post-contrast Cine, and 3-slice vs. 9-slice T1 mapping) and evaluate deep learning-based virtual native enhancement (VNE) models trained under different sequence protocols.

By tracking clinical outcomes, the study seeks to establish a standardized imaging assessment system to improve the early detection, accurate diagnosis, risk stratification, and prognostic prediction for various types of cardiovascular diseases.

調査の概要

詳細な説明

Cardiovascular disease (CVD) remains a leading cause of global mortality and disability. Accurate and early assessment of cardiac structure, function, and myocardial tissue characteristics is crucial for optimal clinical management. Cardiac Magnetic Resonance (CMR) has evolved from single morphological imaging into advanced multi-modal imaging. By integrating Cine, Late Gadolinium Enhancement (LGE), T1/T2 mapping, and 4D flow techniques, multi-modal CMR serves as a "gold standard" that provides a comprehensive macroscopic and cellular-level evaluation, including the identification of myocardial fibrosis, edema, and complex hemodynamic alterations.

Despite its clinical potential, systematic research comparing the diagnostic efficacy and prognostic value of multi-modal CMR features across a broad spectrum of cardiovascular diseases (such as ischemic heart disease, non-ischemic cardiomyopathy, and valvular diseases) is still lacking. Furthermore, optimization of scan efficiency, standardization of sequence acquisition protocols, and the development of contrast-free or AI-driven virtual imaging techniques (such as deep learning-based virtual native enhancement ) represent critical avenues to enhance clinical utility.

This prospective, observational registry study is designed to address this gap by establishing a large-scale, standardized CMR imaging database. Approximately 2,000 patients with clinically suspected or confirmed CVD will be consecutively enrolled. Following routine clinical care pathways, participants will undergo a "one-stop" multi-modal CMR examination using 3.0T MRI scanners.

To refine imaging protocols and validate novel synthetic imaging algorithms, a subset/sub-cohort analysis will specifically investigate the impacts of acquisition parameters-comparing performance between pre-contrast Cine vs. post-contrast Cine, as well as 3-slice vs. 9-slice T1 mapping protocols-on downstream machine learning/deep learning models for virtual native enhancement and tissue characterization.

The primary objectives are to: 1) systematically delineate the imaging feature spectrum across different CVD subtypes; 2) optimize multi-modal CMR acquisition protocols and validate deep learning models for virtual image generation (e.g., VNE); 3) assess the sensitivity of hemodynamic and tissue-characterization parameters (especially T1 mapping and extracellular volume [ECV]) in detecting early cardiac damage; and 4) explore the correlation between multi-modal CMR parameters and major adverse cardiovascular events (MACE) during the follow-up period. Ultimately, this study aims to provide robust, evidence-based support for precision diagnosis and risk stratification in cardiovascular medicine.

研究の種類

観察的

入学 (推定)

2000

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:jiaqi Fan
  • 電話番号:+86 15267029492
  • メール:jqfan@zju.edu.cn

研究連絡先のバックアップ

研究場所

    • Zhejiang
      • Hangzhou、Zhejiang、中国、310009
        • 募集
        • The Second Affiliated Hospital Zhejiang University School of Medicine
        • コンタクト:

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

サンプリング方法

非確率サンプル

調査対象母集団

The study population consists of consecutive adult patients (aged 18 years and older) who are clinically suspected or confirmed to have cardiovascular diseases (CVD), including but not limited to ischemic heart disease, non-ischemic cardiomyopathy, myocarditis, and valvular heart disease. These participants are enrolled from the Second Affiliated Hospital Zhejiang University School of Medicine. They are patients who are scheduled to undergo a multi-modal cardiac magnetic resonance (CMR) examination as part of their clinical evaluation to determine disease etiology or assess myocardial tissue characteristics.

説明

Inclusion Criteria:

  • Aged 18 years and older, with no gender restrictions.

Clinically suspected or confirmed cardiovascular disease (including but not limited to ischemic heart disease, non-ischemic cardiomyopathy, myocarditis, valvular disease, etc.), requiring a cardiac magnetic resonance (CMR) examination to determine the etiology or evaluate myocardial tissue characteristics.

No contraindications to magnetic resonance examination, and able to cooperate with breath-holding instructions.

Voluntarily participate in this study and sign a written informed consent form.

Exclusion Criteria:

  • Absolute contraindications: Implantation of non-MRI compatible metallic foreign bodies (e.g., old pacemakers, implantable cardioverter-defibrillators [ICD], aneurysm clips, etc.).

Relative contraindications: Severe claustrophobia, unable to complete the examination despite communication.

Severe renal insufficiency.

Special populations: Pregnant or lactating women.

Presence of severe arrhythmias (e.g., persistent atrial fibrillation) leading to severely impaired magnetic resonance signal acquisition, rendering the image quality inadequate for diagnosis.

Poor expected compliance: Unable to complete follow-up, or deemed unsuitable for enrollment by the investigator for other reasons.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Diagnostic Efficacy of Multi-modal CMR Parameters (AUC)
時間枠:Baseline (at the time of CMR scan)
The Area Under the Receiver Operating Characteristic Curve (AUC) will be calculated to assess the diagnostic performance of multi-modal CMR parameters (specifically T1 mapping and extracellular volume [ECV]) in differentiating various types of cardiovascular diseases (e.g., ischemic vs. non-ischemic). The final clinical diagnosis based on ESC/ACC guidelines will serve as the gold standard.
Baseline (at the time of CMR scan)

二次結果の測定

結果測定
メジャーの説明
時間枠
Correlation Between Imaging Parameters and Clinical Indicators
時間枠:Baseline
To evaluate the Pearson or Spearman correlation coefficients between multi-modal CMR parameters (such as LGE, T1/T2 mapping, 4D flow metrics) and clinical functional/laboratory indicators.
Baseline
Incidence of Major Adverse Cardiovascular Events (MACE)
時間枠:Up to 3 years
To evaluate the occurrence rate of MACE during the follow-up period. MACE is defined as a composite of cardiac death, readmission for heart failure, malignant arrhythmia (sustained ventricular tachycardia/ventricular fibrillation), and non-fatal myocardial infarction.
Up to 3 years
Model performance for virtual native enhancement across different sequence acquisition protocols
時間枠:At baseline
Model performance for virtual LGE generation across sequence protocols: Structural Similarity Index Measure (SSIM)
At baseline
Model performance for virtual LGE generation across sequence protocols: Peak Signal-to-Noise Ratio (PSNR)
時間枠:At baseline
Peak Signal-to-Noise Ratio (PSNR) will be evaluated to compare virtual LGE algorithms trained on pre- vs. post-contrast Cine and 3-slice vs. 9-slice T1 mapping protocols.
At baseline
Model performance for virtual LGE generation across sequence protocols: DICE coefficient
時間枠:At baseline
DICE coefficient will be evaluated to compare virtual LGE algorithms trained on pre- vs. post-contrast Cine and 3-slice vs. 9-slice T1 mapping protocols.
At baseline

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年1月1日

一次修了 (推定)

2028年12月31日

研究の完了 (推定)

2028年12月31日

試験登録日

最初に提出

2026年5月26日

QC基準を満たした最初の提出物

2026年5月26日

最初の投稿 (実際)

2026年6月1日

学習記録の更新

投稿された最後の更新 (実際)

2026年7月28日

QC基準を満たした最後の更新が送信されました

2026年7月26日

最終確認日

2026年5月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

The individual participant data (IPD) will not be shared because of current institutional policies and national data security regulations regarding the protection of patient privacy and human genetic resources. The data contains sensitive medical imaging information that is restricted from being transferred or shared outside the participating institution without specific governmental and ethical approvals.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する