このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Data Collection Study Using CS BP Pillow System

2026年8月2日 更新者:CardiacSense Ltd.

A Data Collection Study to Collect Blood Pressure Data Using the CardiacSense BP Pillow System for Algorithm Development

Collect raw data from CS BP Pillow System ,CS BP Plate System, IR (Infrared) PPG (Photoplethysmography) sensors and Arterial line (A-line) in volunteers. The data collected in the study will be used for development of the CS BP algorithms.

調査の概要

詳細な説明

This is a prospective data collection single-site study designed to collect blood pressure (BP) waveforms and estimate BP via the CS BP Pillow System, CS BP Plate System and IR-Pillow in parallel with arterial line (A-line data). The data collected will be used for algorithms development of the CS BP systems.

The study includes a screening phase followed by BP data collection session using the CS Pillow System, CS BP Plate System, IR-Pillows and an A-line. Participants will be recruited by the Investigator according to the study eligibility criteria.

A total of 50 participants who meet eligibility criteria will be enrolled in the study in 3 cohorts: Cohort I and Cohort II will include 20 participants, and Cohort III will include 10 participants.

After informed consent is obtained, demographic information, medical history, current medications use and wrist circumference measurement will be recorded. A modified Allen's test, a lateral difference test and additional assessments will be performed to confirm eligibility criteria. In participants who meet the eligibility criteria, the CS BP study systems will be fitted and an A-line will be inserted into the radial artery. A dynamic response calculation will be performed to confirm the integrity of the inserted line.

After the participant has rested for at least 5 minutes, simultaneous BP recordings using the CS BP Pillow System, CS BP Plate System, IR Pillows and A-line will begin and continue for about 1 hour.

Upon completion of data collection, all devices will be removed, and adverse events will be assessed and documented.

The end of study for each participant is defined as the completion of device removal and completion of adverse event follow-up. The end of the study is defined as completion of 50 evaluable participant datasets

研究の種類

介入

入学 (実際)

50

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Colorado
      • Louisville、Colorado、アメリカ、80027
        • Element Boulder Avista Adventist Hospital Plaza

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

はい

説明

Inclusion Criteria:

  • 20-80 years old.
  • Ability and willingness to sign and understand an informed consent form.
  • The participant has a palpable radial pulse in both wrists.
  • The participant is willing and able to be fitted with the investigational device, A-line, and reference cuff, and is willing and able to undergo all study procedures, including 1 hour of recording with the investigational device and A-line.
  • The participant was fitted with both CS BP Plate System devices (one for each hand) and CardiacSense technician has determined the measurement quality to be sufficient.

Exclusion Criteria:

  • Participant who are currently enrolled in another clinical investigation in which the intervention might compromise the safety of the participant or interfere with the data collected.
  • Participant whose body habitus precludes them from wearing the investigational device on their wrists.
  • Female participants who self-reported as pregnant based on a urine pregnancy test, or who are self-reported as trying to get pregnant or who are breastfeeding.
  • Participant whose BMI is greater than 35.
  • Participant with a documented medical history of cardiac arrhythmia.
  • Participant with diagnosed diabetes mellitus.
  • Participant with implanted cardiac defibrillators or pacemakers, Ventricular Assist Device (VAD) or other mechanical circulatory support devices, whether intracorporal or extracorporeal.
  • Participant with stage 4 or stage 5 end-stage renal disease, or participants with arteriovenous shunts.
  • Participant with pheochromocytoma or primary hyperaldosteronism.
  • Participant with diagnosed heart failure with New York Heart Association (NYHA) class III/IV, or participants with a history of stroke.
  • Participant with a known clotting disorders or currently taking a prescription anticoagulants (daily aspirin use is permitted).
  • Participant with an infection requiring antibiotics.
  • Participant with peripheral artery disease
  • Participants with compromised circulation, including Raynaud's syndrome.
  • Participant has a fracture, severe trauma, or anatomical deformity involving the wrist intended for placement of the investigational devices, which could interfere with proper fitting or function of the devices.
  • Participant with moderate to severe valvulopathies.
  • Participant with primary vasculitis.
  • Participant with tremors or otherwise unable to remain still for 1 hour.
  • The left to right arm lateral difference of the average systolic blood pressure values is more than 15 mmHg or the lateral difference of the average diastolic blood pressure values is more than 10 mmHg.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:他の
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:CS BP Pillow System, CS BP Plate System and IR Pillows
Data collected from the systems will be compared to data collected from Arterial Line

Device: CS Pillow System

CS Pillow System estimates blood pressure using ECG and tonometry signals. It includes a tonometry sensor embedded in a biocompatible pillow, positioned over the radial artery with a wristband for improved sensitivity and comfort and ECG chest wet electrodes fitted on the torso.

CS BP Plate System estimates blood pressure using ECG and PPG. The system consists of a handheld, battery-operated Plate with integrated optical and ECG sensors contacted by the thumb.

Infrared (IR) Pillow contain a PPG sensor (IR LED and photodiode) embedded in a biocompatible "pillow. The IR Pillow is placed over the radial artery. This sensor enables estimation of arterial compliance, an important factor influencing the blood pressure-blood volume relationship.

Data collected using the CS BP Pillow System and the CS Plate System will be compared to data collected using Arterial Line.

他の名前:
  • Arterial Line

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Number of subjects with complete protocol-defined multi-modal physiological signal acquisition
時間枠:day 1, 1 hour

The primary outcome measure is the number of subjects with complete protocol-defined multi-modal physiological signal acquisition.

Multi-modal physiological signal acquisition includes simultaneous recording of: (i) photoplethysmography (PPG); ii) single lead electrocardiography (ECG); iii) tonometry signals from the investigational BP Pillow System ; (iv) IR PPG signals (v) continuous invasive arterial blood pressure signals.

day 1, 1 hour

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年2月10日

一次修了 (実際)

2026年4月30日

研究の完了 (実際)

2026年4月30日

試験登録日

最初に提出

2026年4月8日

QC基準を満たした最初の提出物

2026年6月3日

最初の投稿 (実際)

2026年6月9日

学習記録の更新

投稿された最後の更新 (実際)

2026年8月4日

QC基準を満たした最後の更新が送信されました

2026年8月2日

最終確認日

2026年8月1日

詳しくは

本研究に関する用語

キーワード

その他の研究ID番号

  • 027_BP_DC_US

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

はい

米国で製造され、米国から輸出された製品。

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する