このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Safety of a Contraceptive Copper Vaginal Ring

2026年6月19日 更新者:Elle, MD Biotechnologies Inc.

Prospective Elavulation of the Safety of a Novel Copper Vaginal Contraceptive Ring (CVR)

Many birth control options today come with unwanted side effects or risks. Hormonal methods can affect both mental and physical health, while devices like copper IUDs carry risks such as uterine perforation or infection. This study is testing a new option: a copper vaginal ring (CVR) - a non-hormonal, non-invasive contraceptive that can be self-inserted, similar to a other vaginal rings like NuvaRing or Annovera.

The main goal of this study is to assess whether the copper vaginal ring is safe to use. Researchers will also look at how comfortable and easy it is to use, whether participants follow the instructions, and how much copper accumulates in cervical mucus and vaginal fluid during use.

The study will enroll 8 women of childbearing age. Participants wear the ring continuously for 28 days, inserting it on Day 5 of their menstrual cycle. Over the course of the study, participants will attend 8 in-person clinic visits, which include pelvic exams, vaginal swabs, blood draws, and cervical mucus collection. On the day the ring is removed (Day 28), small tissue samples (biopsies) are taken from the vagina and uterine lining. At the end of the study, participants will complete a short survey about their experience with the ring.

調査の概要

状態

まだ募集していません

詳細な説明

Current contraceptive options have a variety of unwanted risks and side effects. Hormonal options are among the most effective and widely used contraceptives but come with a long list of potential risks. Hormonal birth control can lead to impaired glucose metabolism, reduced bone mineral density, headaches, poor libido, irregular periods, depression and suicide. High efficacy contraceptive options (such as intrauterine devices; IUDs) have their own drawbacks. While IUDs are generally safe, they pose more serious risks such as infection, perforation of the uterine wall during insertion, or the IUD being expelled from the uterus. They also involve a medical procedure to insert and remove. Therefore, many women prefer less invasive options when considering birth control methods. There is a gap in the current options for non-hormonal birth control methods that are minimally invasive and pose few serious risks.

The copper vaginal ring (CVR) is a novel contraceptive device for the prevention of pregnancy. The copper ring utilizes a non-hormonal design and is anticipated to have fewer side effects than the copper IUD due to its placement further from the uterus, its shorter duration of use, and the fact that insertion does not require an invasive procedure.

The primary objective of this study is to determine the safety of a copper-containing vaginal ring in women. The secondary objectives of this study are to assess the fit, tolerability and adherence to copper vaginal ring instructions for use, and to determine what concentration of copper accumulates in the cervical mucus and vaginal fluid during use of the ring.

The study will enroll 8 women of childbearing age. All of the participants will use the study device for a duration of 28 days. Participants will come back to the clinic on day 5 of their cycle for a baseline assessment and to insert the ring. After 28 days of continuous use, all the participants will have their vaginal rings removed.

The study involves undergoing pelvic examinations, collection of vaginal fluid using vaginal swabs, collection of blood samples and cervical mucus before the trial starts (baseline), followed by pelvic exams, vaginal swabs, cervical mucus and blood collection occurring again at each of the 8 in-person visits. Visits occur at baseline, and on days 1, 2, 7, 14, 21, 28 and 35. On day 28, immediately after removal of the ring, biopsy samples from both the vagina and the endometrium will be taken.

At the end of the 28-day cycle, during the removal visit, all the participants will complete a survey with questions about the usability, tolerability, acceptability and adherence to use of the copper vaginal ring.

研究の種類

介入

入学 (推定)

8

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:Teresa Flaxman, PhD
  • 電話番号:(613)738-8400
  • メール:tflaxman@ohri.ca

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人

健康ボランティアの受け入れ

はい

説明

Inclusion Criteria:

  • Biological female
  • Age >18
  • Premenopausal women
  • Regular, normal, cyclic menses, with a usual length of 21 to 35 days
  • Willing to give voluntary consent, sign an informed consent form and comply with study procedures as required by the protocol

Exclusion Criteria:

  • Use of oral contraceptives, Copper-IUD, hormonal-IUD, another intravaginal contraceptive device, or any other method of female birth control within 3 months prior to study enrollment
  • Postmenopausal
  • Biological male
  • Positive urine pregnancy test at screening visit
  • Use of hormone therapy; injectable within the past 6 months; implantable within the past 3 months;
  • Presence of a vaginal/cervical/uterine anomaly or a diagnosed pathology that effects the vaginal cavity and may impair the ability to safely insert/remove a vaginal ring.
  • The presence of certain conditions of relevance to vaginal ring use, such as cervicitis, vaginitis or bleeding cervical erosion; lichen sclerosis, lichen planus or vaginismus; Papanicolau (PAP) grade III-V cervical smear result; prolapse of uterine cervix, cystocele and/or rectocele; severe or chronic constipation, dyspareunia or other coital problems; .
  • History or current diagnosis of any of the following:
  • gynecological cancer
  • fibroids
  • polycystic ovary syndrome
  • Past exposure to radiation therapy to the pelvis, or planned radiation therapy to the pelvis during the study;
  • Current diagnosis of a sexually transmitted disease;
  • Wilson's Disease;
  • Known allergy to metal or silicone
  • Had an abortion or breastfeeding within 2 months before the start of the trial;
  • Presence of a significant medical condition or health concern that, in the opinion of the investigator, may impact the patient's safety or the study's outcomes;
  • A condition that, in the opinion of the investigator, precludes the patient from being able to provide informed consent;
  • Inability or unwillingness to refrain from using a tampon/menstrual cup for the duration of the study.
  • Known inability to tolerate products/devices in the vagina (i.e., tampons, menstrual cups, vaginal rings, etc.)

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:他の
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:CVR
Participants in the CVR arm will use the Copper Vaginal Ring for 28 days
The copper vaginal ring (CVR) is a non-hormonal vaginal ring designed for prevention of pregnancy

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Adverse Events [Safety]
時間枠:From enrollment to the end of treatment on Day 35
Safety of the CVR will be assessed by recording all adverse events (AEs). AEs will be recorded and categorized based on their relationship to the study device and their expectedness. Serious Adverse Events (SAEs) and Unanticipated Adverse Device Affects (UADEs) will be tracked and represent the key metrics for an "unsafe" outcome with device use. These outcomes will be obtained by patient reports.
From enrollment to the end of treatment on Day 35

二次結果の測定

結果測定
メジャーの説明
時間枠
Acceptability/Tolerability of the Device
時間枠:Assessed on Day 28 upon removal of the device
Acceptability and tolerability of device use, including ease of insertion, aspects liked most and least about the device, and comfort by both partners during intercourse with the device inserted will be assessed using a validated Vaginal Ring tolerability questionnaire. The questionnaire consists of 20 questions and all answers are scored on a 5-point likert scale. Higher scores equate to higher acceptability/tolerability of the ring.
Assessed on Day 28 upon removal of the device
Device Malfunctions and Complications [Safety]
時間枠:From enrollment to the end of treatment on Day 35
Device malfunctions include problems with the ring's structural integrity, copper component dimensional/tolerance failures, material degradation, or problems with the packaging. Device-related complications refer to problems that are mechanical or physical in nature (such as expulsion), local tissue effects, copper-specific problems, partner/coitus-related complications, or infection attributable to the ring. These outcomes will be obtained by the principle investigator during physical exams and by patient reports.
From enrollment to the end of treatment on Day 35

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Sukhbir Singh, MD、The Ottawa Hospital

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年10月1日

一次修了 (推定)

2027年2月28日

研究の完了 (推定)

2027年4月30日

試験登録日

最初に提出

2026年6月16日

QC基準を満たした最初の提出物

2026年6月19日

最初の投稿 (実際)

2026年6月24日

学習記録の更新

投稿された最後の更新 (実際)

2026年6月24日

QC基準を満たした最後の更新が送信されました

2026年6月19日

最終確認日

2026年6月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • EMD-CIP-001

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

This is an industry sponsored study and the results will be used to inform whether future studies of the device are warranted. IPD is unlikely to be shared with other researchers.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する