Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Safety of a Contraceptive Copper Vaginal Ring

19. juni 2026 oppdatert av: Elle, MD Biotechnologies Inc.

Prospective Elavulation of the Safety of a Novel Copper Vaginal Contraceptive Ring (CVR)

Many birth control options today come with unwanted side effects or risks. Hormonal methods can affect both mental and physical health, while devices like copper IUDs carry risks such as uterine perforation or infection. This study is testing a new option: a copper vaginal ring (CVR) - a non-hormonal, non-invasive contraceptive that can be self-inserted, similar to a other vaginal rings like NuvaRing or Annovera.

The main goal of this study is to assess whether the copper vaginal ring is safe to use. Researchers will also look at how comfortable and easy it is to use, whether participants follow the instructions, and how much copper accumulates in cervical mucus and vaginal fluid during use.

The study will enroll 8 women of childbearing age. Participants wear the ring continuously for 28 days, inserting it on Day 5 of their menstrual cycle. Over the course of the study, participants will attend 8 in-person clinic visits, which include pelvic exams, vaginal swabs, blood draws, and cervical mucus collection. On the day the ring is removed (Day 28), small tissue samples (biopsies) are taken from the vagina and uterine lining. At the end of the study, participants will complete a short survey about their experience with the ring.

Studieoversikt

Status

Har ikke rekruttert ennå

Intervensjon / Behandling

Detaljert beskrivelse

Current contraceptive options have a variety of unwanted risks and side effects. Hormonal options are among the most effective and widely used contraceptives but come with a long list of potential risks. Hormonal birth control can lead to impaired glucose metabolism, reduced bone mineral density, headaches, poor libido, irregular periods, depression and suicide. High efficacy contraceptive options (such as intrauterine devices; IUDs) have their own drawbacks. While IUDs are generally safe, they pose more serious risks such as infection, perforation of the uterine wall during insertion, or the IUD being expelled from the uterus. They also involve a medical procedure to insert and remove. Therefore, many women prefer less invasive options when considering birth control methods. There is a gap in the current options for non-hormonal birth control methods that are minimally invasive and pose few serious risks.

The copper vaginal ring (CVR) is a novel contraceptive device for the prevention of pregnancy. The copper ring utilizes a non-hormonal design and is anticipated to have fewer side effects than the copper IUD due to its placement further from the uterus, its shorter duration of use, and the fact that insertion does not require an invasive procedure.

The primary objective of this study is to determine the safety of a copper-containing vaginal ring in women. The secondary objectives of this study are to assess the fit, tolerability and adherence to copper vaginal ring instructions for use, and to determine what concentration of copper accumulates in the cervical mucus and vaginal fluid during use of the ring.

The study will enroll 8 women of childbearing age. All of the participants will use the study device for a duration of 28 days. Participants will come back to the clinic on day 5 of their cycle for a baseline assessment and to insert the ring. After 28 days of continuous use, all the participants will have their vaginal rings removed.

The study involves undergoing pelvic examinations, collection of vaginal fluid using vaginal swabs, collection of blood samples and cervical mucus before the trial starts (baseline), followed by pelvic exams, vaginal swabs, cervical mucus and blood collection occurring again at each of the 8 in-person visits. Visits occur at baseline, and on days 1, 2, 7, 14, 21, 28 and 35. On day 28, immediately after removal of the ring, biopsy samples from both the vagina and the endometrium will be taken.

At the end of the 28-day cycle, during the removal visit, all the participants will complete a survey with questions about the usability, tolerability, acceptability and adherence to use of the copper vaginal ring.

Studietype

Intervensjonell

Registrering (Antatt)

8

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

  • Navn: Teresa Flaxman, PhD
  • Telefonnummer: (613)738-8400
  • E-post: tflaxman@ohri.ca

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Voksen

Tar imot friske frivillige

Ja

Beskrivelse

Inclusion Criteria:

  • Biological female
  • Age >18
  • Premenopausal women
  • Regular, normal, cyclic menses, with a usual length of 21 to 35 days
  • Willing to give voluntary consent, sign an informed consent form and comply with study procedures as required by the protocol

Exclusion Criteria:

  • Use of oral contraceptives, Copper-IUD, hormonal-IUD, another intravaginal contraceptive device, or any other method of female birth control within 3 months prior to study enrollment
  • Postmenopausal
  • Biological male
  • Positive urine pregnancy test at screening visit
  • Use of hormone therapy; injectable within the past 6 months; implantable within the past 3 months;
  • Presence of a vaginal/cervical/uterine anomaly or a diagnosed pathology that effects the vaginal cavity and may impair the ability to safely insert/remove a vaginal ring.
  • The presence of certain conditions of relevance to vaginal ring use, such as cervicitis, vaginitis or bleeding cervical erosion; lichen sclerosis, lichen planus or vaginismus; Papanicolau (PAP) grade III-V cervical smear result; prolapse of uterine cervix, cystocele and/or rectocele; severe or chronic constipation, dyspareunia or other coital problems; .
  • History or current diagnosis of any of the following:
  • gynecological cancer
  • fibroids
  • polycystic ovary syndrome
  • Past exposure to radiation therapy to the pelvis, or planned radiation therapy to the pelvis during the study;
  • Current diagnosis of a sexually transmitted disease;
  • Wilson's Disease;
  • Known allergy to metal or silicone
  • Had an abortion or breastfeeding within 2 months before the start of the trial;
  • Presence of a significant medical condition or health concern that, in the opinion of the investigator, may impact the patient's safety or the study's outcomes;
  • A condition that, in the opinion of the investigator, precludes the patient from being able to provide informed consent;
  • Inability or unwillingness to refrain from using a tampon/menstrual cup for the duration of the study.
  • Known inability to tolerate products/devices in the vagina (i.e., tampons, menstrual cups, vaginal rings, etc.)

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Annen
  • Tildeling: N/A
  • Intervensjonsmodell: Enkeltgruppeoppdrag
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: CVR
Participants in the CVR arm will use the Copper Vaginal Ring for 28 days
The copper vaginal ring (CVR) is a non-hormonal vaginal ring designed for prevention of pregnancy

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Adverse Events [Safety]
Tidsramme: From enrollment to the end of treatment on Day 35
Safety of the CVR will be assessed by recording all adverse events (AEs). AEs will be recorded and categorized based on their relationship to the study device and their expectedness. Serious Adverse Events (SAEs) and Unanticipated Adverse Device Affects (UADEs) will be tracked and represent the key metrics for an "unsafe" outcome with device use. These outcomes will be obtained by patient reports.
From enrollment to the end of treatment on Day 35

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Acceptability/Tolerability of the Device
Tidsramme: Assessed on Day 28 upon removal of the device
Acceptability and tolerability of device use, including ease of insertion, aspects liked most and least about the device, and comfort by both partners during intercourse with the device inserted will be assessed using a validated Vaginal Ring tolerability questionnaire. The questionnaire consists of 20 questions and all answers are scored on a 5-point likert scale. Higher scores equate to higher acceptability/tolerability of the ring.
Assessed on Day 28 upon removal of the device
Device Malfunctions and Complications [Safety]
Tidsramme: From enrollment to the end of treatment on Day 35
Device malfunctions include problems with the ring's structural integrity, copper component dimensional/tolerance failures, material degradation, or problems with the packaging. Device-related complications refer to problems that are mechanical or physical in nature (such as expulsion), local tissue effects, copper-specific problems, partner/coitus-related complications, or infection attributable to the ring. These outcomes will be obtained by the principle investigator during physical exams and by patient reports.
From enrollment to the end of treatment on Day 35

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Hovedetterforsker: Sukhbir Singh, MD, The Ottawa Hospital

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

1. oktober 2026

Primær fullføring (Antatt)

28. februar 2027

Studiet fullført (Antatt)

30. april 2027

Datoer for studieregistrering

Først innsendt

16. juni 2026

Først innsendt som oppfylte QC-kriteriene

19. juni 2026

Først lagt ut (Faktiske)

24. juni 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

24. juni 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

19. juni 2026

Sist bekreftet

1. juni 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • EMD-CIP-001

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

IPD-planbeskrivelse

This is an industry sponsored study and the results will be used to inform whether future studies of the device are warranted. IPD is unlikely to be shared with other researchers.

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere