Performance Testing of the Modified Electrocardiogram Lead Placement in Patients Undergoing General Anesthesia

During general anesthesia for surgery, doctors use an electrocardiogram (ECG)-a simple heart monitor-to check for problems like poor blood flow to the heart or irregular heartbeats. Normally, ECG stickers (called electrodes) go on both shoulders and the left side of the belly, right outside the heart area, to get clear readings.

But for shoulder surgery, these spots are in the way of the operation, so doctors often place them elsewhere, like on the breastbone instead of the shoulder. This can give fuzzy or wrong results, missing key changes in the patient's heart-good or bad-during surgery.

To fix this and better watch heart health in shoulder surgery patients, this study tests different ECG sticker spots: the usual ones, the common backup (like on the breastbone), and a new idea-placing them near both temples. Researchers hope to find which setup gives the most accurate heart readings to keep patients safer.

調査の概要

詳細な説明

Background and Rationale Electrocardiogram (ECG) monitoring is essential during general anesthesia to assess heart rate, arrhythmias, and myocardial ischemia, alongside blood pressure. Standard Lead II, derived from limb leads placed on the torso (both clavicles below and left anterior superior iliac spine, outside the heart boundary), aligns best with the heart's electrical axis for accurate rhythm and ischemia detection. However, in shoulder surgeries like arthroscopic rotator cuff repair, surgical incisions overlap these sites, forcing electrode relocation (e.g., to the sternum instead of the shoulder). This inward shift distorts ECG signals, potentially missing normal or abnormal heart changes during surgery. To address this, modified Lead II placements are needed for reliable cardiac surveillance in shoulder surgery patients.

Study Overview This prospective, single-group interventional study evaluates the performance of two modified ECG Lead II configurations compared to the standard during general anesthesia for non-shoulder surgeries (to simulate placement feasibility). The modifications test alternative sites for the left shoulder electrode: sternum center (modified Sternum-Chest Lead II, mSC2) versus temple (modified Temple-Chest Lead II, mTC2). Left-side versions are assessed post-induction in supine position; right-side versions post-surgery. Outcomes focus on ST segment morphology similarity (visual and quantitative) to ensure modified leads maintain diagnostic accuracy without artifacts.

Methods Summary Eligible adults (19-65 years) scheduled for general anesthesia in non-shoulder sites undergo standard monitoring (ECG, NIBP, SpO2) per institutional protocols. After induction and hemodynamic stabilization, three ECG configurations are recorded simultaneously using Vital Recorder software (VitalDB, Republic of Korea) for at least 10 noise-free waves: (1) Standard Lead II; (2) Left mSC2 (sternum, right shoulder, left iliac spine); (3) Left mTC2 (left temple, right shoulder, left iliac spine). Post-surgery, right-side mSC2 and mTC2 are added. Recordings capture preoperative ST segment status (normal/abnormal). Blinded assessors (two researchers, third for ties) evaluate ST similarity visually; quantitative area differences use R/RStudio.

Statistical Considerations Sample size (n=84, 10% dropout) is calculated via McNemar test for paired comparisons, stratified by ST status (normal: 38 pairs; abnormal: 46 pairs), yielding 80% power at $\alpha=0.05$ based on pilot data. Analysis: Stratified McNemar for agreement; R for area differences.

Safety and Ethics Modifications involve brief additional recordings with no added risk beyond standard care. IRB-approved (Dongguk University Ilsan Hospital); informed consent obtained. Data anonymized (case numbers); stored securely for 3 years per regulations.

研究の種類

介入

入学 (推定)

84

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:Hansu Bae, MD
  • 電話番号:080-10-6326-1641
  • メール:hsbae81@gmail.com

研究連絡先のバックアップ

  • 名前:Dongkyu Lee, MD. Ph.D
  • 電話番号:080-10-6431-4217
  • メール:entopic@naver.com

研究場所

    • Gyeonggi-do
      • Goyang-si、Gyeonggi-do、韓国、10326
        • 募集
        • Dongguk University Il-san Hospital
        • コンタクト:
        • コンタクト:
      • Goyang-si、Gyeonggi-do、韓国、10326
        • まだ募集していません
        • Dongguk University Ilsan Hospital
        • コンタクト:
          • Hansu Assistant professor, MD.
          • 電話番号:080-10-6326-1641
          • メール:hsbae81@gmail.com

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  • Adult male and female patients aged 19 to 65 years scheduled for surgery under general anesthesia.
  • Patients scheduled for surgery in areas that do not affect ECG electrode placement (e.g., abdomen, head, face, lower limbs).
  • Patients with normal or abnormal ST segment changes confirmed on preoperative ECG.

Exclusion Criteria:

  • Patients who do not consent to the study.
  • Patients with implanted pacemakers.
  • Patients with a history of heart or lung surgery.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:診断
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:All Participants
All enrolled patients (n=84) undergoing general anesthesia without restrictions on ECG lead placement receive simultaneous ECG monitoring with three lead configurations: standard Lead II (baseline), left-side modified sternum-chest Lead II (mSC2), and left-side modified temple-chest Lead II (mTC2) post-induction. Right-side versions are added post-surgery. This single arm tests ST segment similarity across methods to improve intraoperative cardiac monitoring accuracy
Standard ECG Lead II monitoring: Three electrodes placed on both clavicles below and left anterior superior iliac spine (outside heart boundary). Recorded simultaneously post-induction for at least 10 noise-free waves using Vital Recorder software to establish baseline ST segment morphology during general anesthesia."
他の名前:
  • mSC2
  • mTC2
Modified Sternum-Chest Lead II ECG (mSC2): Electrode relocated to sternum center (replacing left shoulder), with right shoulder and left anterior superior iliac spine. Left-side version recorded post-induction; right-side post-surgery. Assesses ST segment similarity to standard for accurate ischemia detection in anesthesia.
Modified Temple-Chest Lead II ECG (mTC2): Electrode relocated near temple (replacing left shoulder), with right shoulder and left anterior superior iliac spine. Left-side version recorded post-induction; right-side post-surgery. Evaluates ST segment morphology match to standard to enhance cardiac monitoring reliability.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Percentage of participants for whom each modified Lead II configuration demonstrates superior visual similarity to the Standard Lead II
時間枠:Periprocedural
This measure evaluates and compares which of the two modified Lead II configurations (Left modified Temple-Chest Lead II [Lt-mTC2] vs. Left modified Sternum-Chest Lead II [Lt-mSC2]) aligns more accurately with the Standard Lead II. To ensure objectivity, two blinded researchers will independently compare the ECG waveform shapes and determine which modified lead shows superior visual similarity to the Standard Lead II. In cases of disagreement or tie, a third researcher will re-evaluate the waveforms for the final decision. Evaluators will be strictly blinded to the identity of the specific leads being assessed.
Periprocedural

二次結果の測定

結果測定
メジャーの説明
時間枠
Percentage of participants for whom each right-side modified Lead II configuration demonstrates superior visual similarity to the Standard Lead II
時間枠:Periprocedural
This measure evaluates and compares which of the two right-side modified Lead II configurations (Right modified Temple-Chest Lead II [Rt-mTC2] vs. Right modified Sternum-Chest Lead II [Rt-mSC2]) aligns more accurately with the Standard Lead II post-surgery. Two blinded researchers will independently compare the ECG waveform shapes and determine which right-side modified lead shows superior visual similarity to the Standard Lead II. In cases of disagreement or tie, a third researcher will re-evaluate the waveforms for the final decision. Evaluators will be strictly blinded to the identity of the specific leads.
Periprocedural
Mean difference in ST segment amplitude between modified Temple-Chest Lead II (mTC2) and Standard Lead II
時間枠:Periprocedural
The quantitative difference in ST segment amplitude (measured in millimeters or millivolts) will be compared between the mTC2 configuration and the Standard Lead II. Waveform data will be processed using R and RStudio programs to calculate the absolute amplitude differences. A paired t-test will be performed to analyze the statistical agreement and determine if significant differences exist between the two leads.
Periprocedural
Mean difference in ST segment amplitude between modified Sternum-Chest Lead II (mSC2) and Standard Lead II
時間枠:Periprocedural
The quantitative difference in ST segment amplitude (measured in millimeters or millivolts) will be compared between the mSC2 configuration and the Standard Lead II. Waveform data will be processed using R and RStudio programs to calculate the absolute amplitude differences. A paired t-test will be performed to analyze the statistical agreement and determine if significant differences exist between the two leads.
Periprocedural

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年2月25日

一次修了 (推定)

2026年12月17日

研究の完了 (推定)

2027年11月5日

試験登録日

最初に提出

2025年11月15日

QC基準を満たした最初の提出物

2026年7月19日

最初の投稿 (実際)

2026年7月22日

学習記録の更新

投稿された最後の更新 (実際)

2026年7月22日

QC基準を満たした最後の更新が送信されました

2026年7月19日

最終確認日

2026年7月1日

詳しくは

本研究に関する用語

キーワード

追加の関連 MeSH 用語

その他の研究ID番号

  • DUIH IRB 2025-12-018

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

No plan to share individual participant data to protect participant privacy.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する