Illuminated Chopper in Cataract Surgery (IChopper)
Prospective Randomized, Paired-Eye, Comparative Study Between Cataract Surgeries With and Without an Illuminated Chopper
This study compares cataract surgery performed with an illuminated chopper and intracameral illumination with cataract surgery performed under conventional external coaxial microscope illumination. Participants undergoing bilateral cataract surgery will have one eye treated with the illuminated chopper and the other eye treated without the illuminated chopper, with the order randomized between eyes.
The study will evaluate differences in operation time, pupil size, the need for additional intraocular medications or devices, intraoperative and postoperative complications, and postoperative clinical outcomes including visual acuity and intraocular pressure.
調査の概要
状態
条件
詳細な説明
This is a prospective, randomized, paired-eye comparative clinical study in participants undergoing bilateral cataract surgery. Each participant will undergo cataract surgery in both eyes. One eye will be treated using the iChopper illumination chopper with the iVision light source, while the fellow eye will undergo cataract surgery using conventional external coaxial microscope illumination. The order of the surgical method between the right and left eyes will be randomized.
The illuminated chopper provides intracameral illumination during cataract surgery and is designed to improve visualization of intraocular structures while also functioning as a lens chopper. The investigational device has received U.S. FDA 510(k) clearance.
The study will assess intraoperative outcomes including operation time, pupil size, ultrasound usage time, pupil-related surgical difficulties, intraoperative complications, and the use of additional intraocular medications or devices. Postoperative assessments will include visual acuity, manifest refraction, intraocular pressure, and postoperative complications.
Participants will undergo bilateral cataract surgery with the two procedures scheduled approximately 1 to 3 weeks apart. Follow-up assessments will be performed approximately 1 day and 30 days after surgery for each eye.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Florida
-
Cape Coral、Florida、アメリカ、33904
- Tyson Eye
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Age 40 years or older
- Diagnosis of bilateral cataract
- Both eyes suitable for cataract surgery
- Expected postoperative best-corrected visual acuity of 0.2 Snellen or better
- No other secondary ocular surgeries planned during the study period
- Ability to comply with all study procedures and follow-up visits
- Ability and willingness to provide written informed consent
Exclusion Criteria:
- Preoperative ocular or systemic conditions, or medication use, that may affect study outcomes, increase risk to the participant, or predispose to complications, including infectious disease, ocular atrophy, or zonular weakness
- Poorly controlled diabetes mellitus
- Use of alpha-blockers such as tamsulosin for benign prostatic hyperplasia
- Planned femtosecond laser-assisted cataract surgery
- Congenital ocular disorders
- History of ophthalmic surgery in either eye that may affect study outcomes or increase risk, including retinal surgery, glaucoma surgery, or anterior segment surgery
- Inability to provide informed consent
- Pregnancy
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Illuminated Chopper in Right Eye
Participants assigned to this arm undergo cataract surgery using the illuminated chopper in the right eye and cataract surgery under conventional external coaxial microscope illumination in the left eye. |
Cataract surgery is performed using the iChopper illumination chopper with the iVision light source to provide intracameral illumination during phacoemulsification. Cataract surgery is performed under conventional external coaxial illumination from the surgical microscope without use of the illuminated chopper. |
|
実験的:Illuminated Chopper in Left Eye
Participants assigned to this arm undergo cataract surgery under conventional external coaxial microscope illumination in the right eye and cataract surgery using the illuminated chopper in the left eye. |
Cataract surgery is performed using the iChopper illumination chopper with the iVision light source to provide intracameral illumination during phacoemulsification. Cataract surgery is performed under conventional external coaxial illumination from the surgical microscope without use of the illuminated chopper. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Operation Time
時間枠:During cataract surgery
|
Operation time during cataract surgery will be recorded and compared between eyes undergoing surgery with the illuminated chopper and eyes undergoing surgery with conventional microscope illumination. |
During cataract surgery
|
|
Pupil Size During Cataract Surgery
時間枠:During cataract surgery
|
Pupil size during cataract surgery will be assessed and compared between the illuminated chopper and conventional microscope illumination conditions. |
During cataract surgery
|
|
Use of Additional Intraocular Medications
時間枠:During cataract surgery
|
The use of additional intraocular medications during cataract surgery will be recorded and compared between the illuminated chopper and conventional microscope illumination conditions. |
During cataract surgery
|
|
Use of Additional Intraocular Devices
時間枠:During cataract surgery
|
The use of additional intraocular devices during cataract surgery will be recorded and compared between the illuminated chopper and conventional microscope illumination conditions. |
During cataract surgery
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Intraoperative Complications
時間枠:During cataract surgery
|
Intraoperative complications occurring during cataract surgery, including pupil-related and other surgical complications, will be recorded and compared between the two surgical conditions. |
During cataract surgery
|
|
Postoperative Complications
時間枠:From surgery through approximately 30 days after surgery
|
Postoperative complications following cataract surgery will be recorded and compared between eyes treated with and without the illuminated chopper. |
From surgery through approximately 30 days after surgery
|
|
Postoperative Distance Visual Acuity
時間枠:Day 1 and Day 30 after surgery
|
Distance visual acuity will be assessed after cataract surgery and compared between the illuminated chopper and conventional microscope illumination conditions. |
Day 1 and Day 30 after surgery
|
|
Postoperative Intraocular Pressure
時間枠:Day 1 and Day 30 after surgery
|
Intraocular pressure will be assessed during postoperative follow-up and compared between the illuminated chopper and conventional microscope illumination conditions. |
Day 1 and Day 30 after surgery
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Incidence of Adverse Events
時間枠:From surgery through approximately 30 days after surgery
|
The incidence of adverse events following cataract surgery will be assessed, including cystoid macular edema, endophthalmitis, lens luxation, pupillary block, retinal detachment, and persistent elevation of intraocular pressure requiring treatment. |
From surgery through approximately 30 days after surgery
|
|
Incidence of Postoperative Ocular Complications
時間枠:From surgery through approximately 30 days after surgery
|
Ocular complications will be assessed, including flat anterior chamber, vitreous in the anterior chamber, residual lens material, intraocular lens decentration or tilt, posterior capsular fibrosis or opacity, and intraocular pressure elevation requiring treatment. |
From surgery through approximately 30 days after surgery
|
協力者と研究者
スポンサー
捜査官
- スタディディレクター:Dong Heun Nam, MD, PhD、Gachon University Gil Medical Center, College of Medicine, Incheon, Republic of Korea
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- OCL-IIC-01
- RS-2022-00141533 (その他の助成金/資金番号:The Korean government (the Ministry of Science and ICT; the Ministry of Trade, Industry, and Energy))
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
De-identified individual participant data may be shared with qualified researchers upon reasonable request after publication, subject to review by the study investigators and sponsor and in accordance with applicable ethical, privacy, and regulatory requirements.
IPD 共有時間枠
Beginning after publication of the primary study results and available for 5 years thereafter.
IPD 共有アクセス基準
Data will be made available to qualified researchers who submit a reasonable and scientifically sound request. Requests will be reviewed by the study investigators and sponsor. Access will be provided for approved research purposes, subject to appropriate data use agreements and compliance with applicable ethical, privacy, and regulatory requirements.
IPD 共有サポート情報タイプ
- STUDY_PROTOCOL
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。