- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07840885
Illuminated Chopper in Cataract Surgery (IChopper)
Prospective Randomized, Paired-Eye, Comparative Study Between Cataract Surgeries With and Without an Illuminated Chopper
This study compares cataract surgery performed with an illuminated chopper and intracameral illumination with cataract surgery performed under conventional external coaxial microscope illumination. Participants undergoing bilateral cataract surgery will have one eye treated with the illuminated chopper and the other eye treated without the illuminated chopper, with the order randomized between eyes.
The study will evaluate differences in operation time, pupil size, the need for additional intraocular medications or devices, intraoperative and postoperative complications, and postoperative clinical outcomes including visual acuity and intraocular pressure.
Studieoversikt
Status
Forhold
Detaljert beskrivelse
This is a prospective, randomized, paired-eye comparative clinical study in participants undergoing bilateral cataract surgery. Each participant will undergo cataract surgery in both eyes. One eye will be treated using the iChopper illumination chopper with the iVision light source, while the fellow eye will undergo cataract surgery using conventional external coaxial microscope illumination. The order of the surgical method between the right and left eyes will be randomized.
The illuminated chopper provides intracameral illumination during cataract surgery and is designed to improve visualization of intraocular structures while also functioning as a lens chopper. The investigational device has received U.S. FDA 510(k) clearance.
The study will assess intraoperative outcomes including operation time, pupil size, ultrasound usage time, pupil-related surgical difficulties, intraoperative complications, and the use of additional intraocular medications or devices. Postoperative assessments will include visual acuity, manifest refraction, intraocular pressure, and postoperative complications.
Participants will undergo bilateral cataract surgery with the two procedures scheduled approximately 1 to 3 weeks apart. Follow-up assessments will be performed approximately 1 day and 30 days after surgery for each eye.
Studietype
Registrering (Faktiske)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
Florida
-
Cape Coral, Florida, Forente stater, 33904
- Tyson Eye
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Age 40 years or older
- Diagnosis of bilateral cataract
- Both eyes suitable for cataract surgery
- Expected postoperative best-corrected visual acuity of 0.2 Snellen or better
- No other secondary ocular surgeries planned during the study period
- Ability to comply with all study procedures and follow-up visits
- Ability and willingness to provide written informed consent
Exclusion Criteria:
- Preoperative ocular or systemic conditions, or medication use, that may affect study outcomes, increase risk to the participant, or predispose to complications, including infectious disease, ocular atrophy, or zonular weakness
- Poorly controlled diabetes mellitus
- Use of alpha-blockers such as tamsulosin for benign prostatic hyperplasia
- Planned femtosecond laser-assisted cataract surgery
- Congenital ocular disorders
- History of ophthalmic surgery in either eye that may affect study outcomes or increase risk, including retinal surgery, glaucoma surgery, or anterior segment surgery
- Inability to provide informed consent
- Pregnancy
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Behandling
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: Illuminated Chopper in Right Eye
Participants assigned to this arm undergo cataract surgery using the illuminated chopper in the right eye and cataract surgery under conventional external coaxial microscope illumination in the left eye. |
Cataract surgery is performed using the iChopper illumination chopper with the iVision light source to provide intracameral illumination during phacoemulsification. Cataract surgery is performed under conventional external coaxial illumination from the surgical microscope without use of the illuminated chopper. |
|
Eksperimentell: Illuminated Chopper in Left Eye
Participants assigned to this arm undergo cataract surgery under conventional external coaxial microscope illumination in the right eye and cataract surgery using the illuminated chopper in the left eye. |
Cataract surgery is performed using the iChopper illumination chopper with the iVision light source to provide intracameral illumination during phacoemulsification. Cataract surgery is performed under conventional external coaxial illumination from the surgical microscope without use of the illuminated chopper. |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Operation Time
Tidsramme: During cataract surgery
|
Operation time during cataract surgery will be recorded and compared between eyes undergoing surgery with the illuminated chopper and eyes undergoing surgery with conventional microscope illumination. |
During cataract surgery
|
|
Pupil Size During Cataract Surgery
Tidsramme: During cataract surgery
|
Pupil size during cataract surgery will be assessed and compared between the illuminated chopper and conventional microscope illumination conditions. |
During cataract surgery
|
|
Use of Additional Intraocular Medications
Tidsramme: During cataract surgery
|
The use of additional intraocular medications during cataract surgery will be recorded and compared between the illuminated chopper and conventional microscope illumination conditions. |
During cataract surgery
|
|
Use of Additional Intraocular Devices
Tidsramme: During cataract surgery
|
The use of additional intraocular devices during cataract surgery will be recorded and compared between the illuminated chopper and conventional microscope illumination conditions. |
During cataract surgery
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Intraoperative Complications
Tidsramme: During cataract surgery
|
Intraoperative complications occurring during cataract surgery, including pupil-related and other surgical complications, will be recorded and compared between the two surgical conditions. |
During cataract surgery
|
|
Postoperative Complications
Tidsramme: From surgery through approximately 30 days after surgery
|
Postoperative complications following cataract surgery will be recorded and compared between eyes treated with and without the illuminated chopper. |
From surgery through approximately 30 days after surgery
|
|
Postoperative Distance Visual Acuity
Tidsramme: Day 1 and Day 30 after surgery
|
Distance visual acuity will be assessed after cataract surgery and compared between the illuminated chopper and conventional microscope illumination conditions. |
Day 1 and Day 30 after surgery
|
|
Postoperative Intraocular Pressure
Tidsramme: Day 1 and Day 30 after surgery
|
Intraocular pressure will be assessed during postoperative follow-up and compared between the illuminated chopper and conventional microscope illumination conditions. |
Day 1 and Day 30 after surgery
|
Andre resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Incidence of Adverse Events
Tidsramme: From surgery through approximately 30 days after surgery
|
The incidence of adverse events following cataract surgery will be assessed, including cystoid macular edema, endophthalmitis, lens luxation, pupillary block, retinal detachment, and persistent elevation of intraocular pressure requiring treatment. |
From surgery through approximately 30 days after surgery
|
|
Incidence of Postoperative Ocular Complications
Tidsramme: From surgery through approximately 30 days after surgery
|
Ocular complications will be assessed, including flat anterior chamber, vitreous in the anterior chamber, residual lens material, intraocular lens decentration or tilt, posterior capsular fibrosis or opacity, and intraocular pressure elevation requiring treatment. |
From surgery through approximately 30 days after surgery
|
Samarbeidspartnere og etterforskere
Sponsor
Etterforskere
- Studieleder: Dong Heun Nam, MD, PhD, Gachon University Gil Medical Center, College of Medicine, Incheon, Republic of Korea
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- OCL-IIC-01
- RS-2022-00141533 (Annet stipend/finansieringsnummer: The Korean government (the Ministry of Science and ICT; the Ministry of Trade, Industry, and Energy))
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
IPD-planbeskrivelse
De-identified individual participant data may be shared with qualified researchers upon reasonable request after publication, subject to review by the study investigators and sponsor and in accordance with applicable ethical, privacy, and regulatory requirements.
IPD-delingstidsramme
Beginning after publication of the primary study results and available for 5 years thereafter.
Tilgangskriterier for IPD-deling
Data will be made available to qualified researchers who submit a reasonable and scientifically sound request. Requests will be reviewed by the study investigators and sponsor. Access will be provided for approved research purposes, subject to appropriate data use agreements and compliance with applicable ethical, privacy, and regulatory requirements.
IPD-deling Støtteinformasjonstype
- STUDY_PROTOCOL
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
produkt produsert i og eksportert fra USA
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .