このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Function-Friendly Semi-Fowler Positioning for Coronary Angiography and PCI

2026年11月12日 更新者:Shanghai Zhongshan Hospital

Pilot Study on the Feasibility and Safety of Function-Friendly Semi-Fowler Positioning in Coronary Angiography and Percutaneous Coronary Intervention

This study will assess whether planned coronary angiography (CAG), and simple percutaneous coronary intervention (PCI) when needed, can be completed safely and technically while participants are in a semi-sitting position with the head of the procedure table raised to 60 degrees. Ten clinically stable adults scheduled for an elective procedure are planned. The first stage will include participants undergoing CAG. After a safety review, the study may include participants expected to need only simple PCI. Heart rhythm, blood pressure, and blood oxygen will be monitored continuously. If predefined safety criteria occur, staff will lower the table or return the participant to a flat position and provide usual clinical care. Researchers will describe procedure completion, image quality, radiation exposure, contrast use, tolerance of the position, and safety events through 3 days after the procedure. This exploratory study is not designed to establish treatment efficacy.

調査の概要

状態

まだ募集していません

詳細な説明

This is a prospective, single-center, open-label, single-arm, staged early-feasibility study at Zhongshan Hospital, Fudan University. The planned enrollment is 10 participants aged 18 to 75 years. Eligible participants are clinically stable and scheduled for elective transradial CAG or planned simple PCI, and can tolerate a monitored 60-degree semi-Fowler position for at least 10 minutes before the procedure. The first stage prioritizes CAG. Participants expected to need only simple PCI may be enrolled only after a safety review confirms that the workflow is executable without unacceptable risk. During CAG and, when clinically indicated, simple PCI, the procedure table will be raised to a default head elevation of 60 degrees. ECG, blood pressure, and oxygen saturation will be monitored continuously. If chest pain, significant dyspnea, persistent oxygen saturation below 90%, systolic blood pressure below 90 mmHg or a decrease of at least 30% requiring intervention, sustained ventricular tachycardia or fibrillation, cerebral hypoperfusion, equipment collision, catheter or tubing traction, or another predefined safety concern occurs, the positioning intervention will stop and the table will be lowered or the participant returned to 0-degree supine; usual clinical care will take priority. CAG and PCI technical success will be described among participants undergoing the respective procedure. Safety events will be collected from the start of the positioning intervention through 3 days after the procedure. Other measures include image quality, completion of standard projections, fluoroscopy time, dose-area product, contrast volume, procedure duration, positioning changes, and tolerance. No investigational drug is used. The commercial angiography X-ray system is used as a carrier for the positioning intervention; the study does not modify or evaluate the device.

研究の種類

介入

入学 (推定)

10

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究場所

      • Shanghai、中国
        • Zhongshan Hospital, Fudan University
        • コンタクト:

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年~75年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  1. Age 18 to 75 years.
  2. Clinically stable and scheduled for elective coronary angiography (CAG) or planned simple percutaneous coronary intervention (PCI), with no ongoing resting ischemia.
  3. Meets clinical indications for coronary angiography or intervention, with ischemic evidence consistent with coronary artery disease based on symptoms, ECG, or noninvasive imaging.
  4. Planned radial access; the operator expects the procedure can be performed using standard catheters and devices.
  5. Able to tolerate a monitored 60-degree semi-Fowler position for at least 10 minutes before the procedure.
  6. Body size, weight, shoulder width, and range of motion are within equipment and support-system limits, and the participant can be secured using the manufacturer-approved fixation system.
  7. Able to understand the study and provide written informed consent.

Exclusion Criteria:

  1. Pregnant or breastfeeding, or the participant or spouse plans pregnancy within the next 6 months.
  2. Known contraindication to local anesthetic or history of severe contrast-media allergy.
  3. Neurologic or psychiatric disease or language impairment that prevents effective communication or cooperation.
  4. Serious comorbidity with expected survival less than 6 months.
  5. Uncontrolled hypertension (screening systolic blood pressure >180 mmHg or diastolic blood pressure >100 mmHg) or baseline systolic blood pressure <100 mmHg.
  6. Acute coronary syndrome, ongoing ischemia, hemodynamic instability, cardiogenic shock, or need for emergency CAG/PCI.
  7. Decompensated heart failure, left ventricular ejection fraction <30%, inability to maintain oxygenation at rest, or estimated glomerular filtration rate <30 mL/min/1.73 m^2.
  8. Known or highly suspected high-risk left main disease, chronic total occlusion, complex bifurcation disease, severe calcification, or other anatomy expected to require complex PCI.
  9. Platelet count <50 × 10^9/L or coagulation results outside the institution usual acceptable range.
  10. Participation in another clinical trial or research study within 2 months before screening.
  11. Back pain, stiffness, limited mobility, or injury preventing tolerance of transition from supine to the study position.
  12. Inability to secure the torso reliably, inability to complete the pre-procedure positioning-tolerance test, or investigator judgment that emergency return to supine may be restricted.
  13. Any other condition for which the investigator considers participation unsafe.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:他の
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Function-Friendly Semi-Fowler Positioning

All participants receive the same positioning intervention during elective transradial CAG and, if clinically indicated, simple PCI. The procedure table is raised to a default head elevation of 60 degrees, with continuous ECG, blood pressure, and oxygen saturation monitoring. If predefined safety concerns occur, the table angle is lowered or the participant is returned to 0-degree supine and usual clinical care is provided.

The procedure table head is elevated to a default 60-degree semi-Fowler position during elective transradial coronary angiography and, if clinically indicated, simple PCI. ECG, blood pressure, and oxygen saturation are continuously monitored. If predefined safety criteria occur, the table angle is reduced or the participant is immediately returned to 0-degree supine and usual clinical care is provided. The commercial angiography X-ray system and adjustable procedure table are used as available clinical equipment; no device hardware, software, collision protection, interlocks, image processing, or dose-control functions are modified or evaluated.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Proportion of Participants With Coronary Angiography (CAG) Technical Success
時間枠:During the CAG procedure

The number of participants undergoing CAG who complete the planned CAG in the prespecified semi-Fowler position without position-related unplanned return to supine or substantial angle reduction, procedure discontinuation, access-site change, missing key projections, or participant/equipment collision, and whose images are independently confirmed to be diagnostic, divided by the number of participants undergoing CAG.

During the CAG procedure
Proportion of Participants With Percutaneous Coronary Intervention (PCI) Technical Success
時間枠:During the PCI procedure

Among participants who undergo PCI, the proportion who complete planned device delivery, treatment, and withdrawal while meeting the protocol-defined positioning and safety requirements. PCI success is calculated using participants who undergo PCI as the denominator.

During the PCI procedure
Participants With Position-Related Serious Adverse Events or Prespecified Safety Events
時間枠:From the start of the positioning intervention through 3 days after the procedure

Number and proportion of participants experiencing a position-related serious adverse event or any prespecified safety event: hemodynamic instability, hypoxia, sustained arrhythmia, cerebral hypoperfusion, unplanned respiratory or circulatory support, mechanical collision, or emergency return to supine.

From the start of the positioning intervention through 3 days after the procedure

二次結果の測定

結果測定
メジャーの説明
時間枠
Diagnostic Acceptability of Coronary Angiography Images
時間枠:During the procedure

Coronary angiography and fluoroscopy image quality rated on a 1-to-3 Likert scale; a score of 2 or 3 is acceptable. Images are assessed by two independent physicians, with adjudication by a third if needed.

During the procedure
Completion of Standard Coronary Angiographic Views and Visualization of Major Coronary Segments
時間枠:During the procedure

Completion of standard left anterior oblique, right anterior oblique, cranial, and caudal projections, and the ability to visualize the left anterior descending, left circumflex, and right coronary arteries and their major branches.

During the procedure
Total Fluoroscopy Time
時間枠:During the procedure

Total fluoroscopy time recorded during the CAG and, if performed, PCI procedure.

During the procedure
Dose-Area Product (DAP)
時間枠:During the procedure

Dose-area product and other radiation dose parameters recorded by the angiography system.

During the procedure
Contrast Volume
時間枠:During the procedure

Total contrast-media volume administered during the procedure.

During the procedure
Procedure Duration
時間枠:During the procedure

Total duration of the CAG procedure and, if performed, PCI procedure, recorded as specified in the study CRF.

During the procedure
Positioning Tolerance and Adjustments
時間枠:During the procedure

Table-head angle, number and reasons for position adjustments, participant symptoms, unplanned return to 0-degree supine, and equipment collision events.

During the procedure
Access and Device Delivery Completion
時間枠:During the procedure

Successful radial artery access and completion of planned device delivery and withdrawal, as applicable to the procedure performed.

During the procedure

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Junbo Ge、Fudan University

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年11月25日

一次修了 (推定)

2028年5月1日

研究の完了 (推定)

2028年11月1日

試験登録日

最初に提出

2026年11月12日

QC基準を満たした最初の提出物

2026年11月12日

最初の投稿 (実際)

2026年11月18日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月18日

QC基準を満たした最後の更新が送信されました

2026年11月12日

最終確認日

2026年11月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

未定

IPD プランの説明

The protocol states that any data sharing must use de-identified data and receive the required approvals. Whether individual participant data will be shared, and the timing, access process, and supporting information, have not yet been determined.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する