此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Function-Friendly Semi-Fowler Positioning for Coronary Angiography and PCI

2026年11月12日 更新者:Shanghai Zhongshan Hospital

Pilot Study on the Feasibility and Safety of Function-Friendly Semi-Fowler Positioning in Coronary Angiography and Percutaneous Coronary Intervention

This study will assess whether planned coronary angiography (CAG), and simple percutaneous coronary intervention (PCI) when needed, can be completed safely and technically while participants are in a semi-sitting position with the head of the procedure table raised to 60 degrees. Ten clinically stable adults scheduled for an elective procedure are planned. The first stage will include participants undergoing CAG. After a safety review, the study may include participants expected to need only simple PCI. Heart rhythm, blood pressure, and blood oxygen will be monitored continuously. If predefined safety criteria occur, staff will lower the table or return the participant to a flat position and provide usual clinical care. Researchers will describe procedure completion, image quality, radiation exposure, contrast use, tolerance of the position, and safety events through 3 days after the procedure. This exploratory study is not designed to establish treatment efficacy.

研究概览

地位

尚未招聘

条件

详细说明

This is a prospective, single-center, open-label, single-arm, staged early-feasibility study at Zhongshan Hospital, Fudan University. The planned enrollment is 10 participants aged 18 to 75 years. Eligible participants are clinically stable and scheduled for elective transradial CAG or planned simple PCI, and can tolerate a monitored 60-degree semi-Fowler position for at least 10 minutes before the procedure. The first stage prioritizes CAG. Participants expected to need only simple PCI may be enrolled only after a safety review confirms that the workflow is executable without unacceptable risk. During CAG and, when clinically indicated, simple PCI, the procedure table will be raised to a default head elevation of 60 degrees. ECG, blood pressure, and oxygen saturation will be monitored continuously. If chest pain, significant dyspnea, persistent oxygen saturation below 90%, systolic blood pressure below 90 mmHg or a decrease of at least 30% requiring intervention, sustained ventricular tachycardia or fibrillation, cerebral hypoperfusion, equipment collision, catheter or tubing traction, or another predefined safety concern occurs, the positioning intervention will stop and the table will be lowered or the participant returned to 0-degree supine; usual clinical care will take priority. CAG and PCI technical success will be described among participants undergoing the respective procedure. Safety events will be collected from the start of the positioning intervention through 3 days after the procedure. Other measures include image quality, completion of standard projections, fluoroscopy time, dose-area product, contrast volume, procedure duration, positioning changes, and tolerance. No investigational drug is used. The commercial angiography X-ray system is used as a carrier for the positioning intervention; the study does not modify or evaluate the device.

研究类型

介入性

注册 (估计的)

10

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

      • Shanghai、中国
        • Zhongshan Hospital, Fudan University
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 75年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  1. Age 18 to 75 years.
  2. Clinically stable and scheduled for elective coronary angiography (CAG) or planned simple percutaneous coronary intervention (PCI), with no ongoing resting ischemia.
  3. Meets clinical indications for coronary angiography or intervention, with ischemic evidence consistent with coronary artery disease based on symptoms, ECG, or noninvasive imaging.
  4. Planned radial access; the operator expects the procedure can be performed using standard catheters and devices.
  5. Able to tolerate a monitored 60-degree semi-Fowler position for at least 10 minutes before the procedure.
  6. Body size, weight, shoulder width, and range of motion are within equipment and support-system limits, and the participant can be secured using the manufacturer-approved fixation system.
  7. Able to understand the study and provide written informed consent.

Exclusion Criteria:

  1. Pregnant or breastfeeding, or the participant or spouse plans pregnancy within the next 6 months.
  2. Known contraindication to local anesthetic or history of severe contrast-media allergy.
  3. Neurologic or psychiatric disease or language impairment that prevents effective communication or cooperation.
  4. Serious comorbidity with expected survival less than 6 months.
  5. Uncontrolled hypertension (screening systolic blood pressure >180 mmHg or diastolic blood pressure >100 mmHg) or baseline systolic blood pressure <100 mmHg.
  6. Acute coronary syndrome, ongoing ischemia, hemodynamic instability, cardiogenic shock, or need for emergency CAG/PCI.
  7. Decompensated heart failure, left ventricular ejection fraction <30%, inability to maintain oxygenation at rest, or estimated glomerular filtration rate <30 mL/min/1.73 m^2.
  8. Known or highly suspected high-risk left main disease, chronic total occlusion, complex bifurcation disease, severe calcification, or other anatomy expected to require complex PCI.
  9. Platelet count <50 × 10^9/L or coagulation results outside the institution usual acceptable range.
  10. Participation in another clinical trial or research study within 2 months before screening.
  11. Back pain, stiffness, limited mobility, or injury preventing tolerance of transition from supine to the study position.
  12. Inability to secure the torso reliably, inability to complete the pre-procedure positioning-tolerance test, or investigator judgment that emergency return to supine may be restricted.
  13. Any other condition for which the investigator considers participation unsafe.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:其他
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Function-Friendly Semi-Fowler Positioning

All participants receive the same positioning intervention during elective transradial CAG and, if clinically indicated, simple PCI. The procedure table is raised to a default head elevation of 60 degrees, with continuous ECG, blood pressure, and oxygen saturation monitoring. If predefined safety concerns occur, the table angle is lowered or the participant is returned to 0-degree supine and usual clinical care is provided.

The procedure table head is elevated to a default 60-degree semi-Fowler position during elective transradial coronary angiography and, if clinically indicated, simple PCI. ECG, blood pressure, and oxygen saturation are continuously monitored. If predefined safety criteria occur, the table angle is reduced or the participant is immediately returned to 0-degree supine and usual clinical care is provided. The commercial angiography X-ray system and adjustable procedure table are used as available clinical equipment; no device hardware, software, collision protection, interlocks, image processing, or dose-control functions are modified or evaluated.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Proportion of Participants With Coronary Angiography (CAG) Technical Success
大体时间:During the CAG procedure

The number of participants undergoing CAG who complete the planned CAG in the prespecified semi-Fowler position without position-related unplanned return to supine or substantial angle reduction, procedure discontinuation, access-site change, missing key projections, or participant/equipment collision, and whose images are independently confirmed to be diagnostic, divided by the number of participants undergoing CAG.

During the CAG procedure
Proportion of Participants With Percutaneous Coronary Intervention (PCI) Technical Success
大体时间:During the PCI procedure

Among participants who undergo PCI, the proportion who complete planned device delivery, treatment, and withdrawal while meeting the protocol-defined positioning and safety requirements. PCI success is calculated using participants who undergo PCI as the denominator.

During the PCI procedure
Participants With Position-Related Serious Adverse Events or Prespecified Safety Events
大体时间:From the start of the positioning intervention through 3 days after the procedure

Number and proportion of participants experiencing a position-related serious adverse event or any prespecified safety event: hemodynamic instability, hypoxia, sustained arrhythmia, cerebral hypoperfusion, unplanned respiratory or circulatory support, mechanical collision, or emergency return to supine.

From the start of the positioning intervention through 3 days after the procedure

次要结果测量

结果测量
措施说明
大体时间
Diagnostic Acceptability of Coronary Angiography Images
大体时间:During the procedure

Coronary angiography and fluoroscopy image quality rated on a 1-to-3 Likert scale; a score of 2 or 3 is acceptable. Images are assessed by two independent physicians, with adjudication by a third if needed.

During the procedure
Completion of Standard Coronary Angiographic Views and Visualization of Major Coronary Segments
大体时间:During the procedure

Completion of standard left anterior oblique, right anterior oblique, cranial, and caudal projections, and the ability to visualize the left anterior descending, left circumflex, and right coronary arteries and their major branches.

During the procedure
Total Fluoroscopy Time
大体时间:During the procedure

Total fluoroscopy time recorded during the CAG and, if performed, PCI procedure.

During the procedure
Dose-Area Product (DAP)
大体时间:During the procedure

Dose-area product and other radiation dose parameters recorded by the angiography system.

During the procedure
Contrast Volume
大体时间:During the procedure

Total contrast-media volume administered during the procedure.

During the procedure
Procedure Duration
大体时间:During the procedure

Total duration of the CAG procedure and, if performed, PCI procedure, recorded as specified in the study CRF.

During the procedure
Positioning Tolerance and Adjustments
大体时间:During the procedure

Table-head angle, number and reasons for position adjustments, participant symptoms, unplanned return to 0-degree supine, and equipment collision events.

During the procedure
Access and Device Delivery Completion
大体时间:During the procedure

Successful radial artery access and completion of planned device delivery and withdrawal, as applicable to the procedure performed.

During the procedure

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Junbo Ge、Fudan University

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年11月25日

初级完成 (估计的)

2028年5月1日

研究完成 (估计的)

2028年11月1日

研究注册日期

首次提交

2026年11月12日

首先提交符合 QC 标准的

2026年11月12日

首次发布 (实际的)

2026年11月18日

研究记录更新

最后更新发布 (实际的)

2026年11月18日

上次提交的符合 QC 标准的更新

2026年11月12日

最后验证

2026年11月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

IPD 计划说明

The protocol states that any data sharing must use de-identified data and receive the required approvals. Whether individual participant data will be shared, and the timing, access process, and supporting information, have not yet been determined.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅