High- Versus Low-Density PASCAL Laser Treatment for Proliferative Diabetic Retinopathy
CENTRAL MACULAR THICKNESS AFTER HIGH- VERSUS LOW-DENSITY SINGLE-SESSION PATTERN SCAN LASER PANRETINAL PHOTOCOAGULATION IN PROLIFERATIVE DIABETIC RETINOPATHY: A RANDOMIZED NON-INFERIORITY TRIAL
This study aims to compare the effects of high-density and low-density single-session Pattern Scan Laser (PASCAL) panretinal photocoagulation (PRP) in patients with proliferative diabetic retinopathy (PDR).
Panretinal photocoagulation is a standard treatment for proliferative diabetic retinopathy. However, the number of laser spots applied during a single treatment session varies in clinical practice. This study will investigate whether applying a higher number of laser spots in one session is as safe and effective as applying a lower number of spots, particularly regarding changes in central macular thickness.
Eligible patients with proliferative diabetic retinopathy who have not previously received PRP will be randomly assigned to one of two groups. The low-density group will receive 2,200-3,000 laser spots, while the high-density group will receive 3,200-4,000 laser spots using the PASCAL laser system in a single session.
Central macular thickness will be measured using optical coherence tomography (OCT) before treatment and four weeks after treatment. The main purpose is to determine whether high-density PRP is not inferior to low-density PRP in terms of changes in central macular thickness. Visual acuity and treatment-related adverse effects will also be assessed.
The findings may help determine whether a higher number of laser spots can be safely delivered in a single PASCAL PRP session without causing an unacceptable increase in macular thickness.
調査の概要
状態
研究の種類
入学 (推定)
段階
- 適用できない
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
-
• Adults aged ≥ 18 years
- Type 1 or type 2 diabetes mellitus
- Treatment-naïve PDR with no clinically significant DME on OCT
- BCVA better than or equal to 6/60
- Baseline CMT <300 µm on Spectralis SD-OCT (central 1 mm ETDRS circle), with no intraretinal or subretinal fluid.
- Adequate pupil dilation and media clarity to perform OCT and laser photocoagulation
Exclusion Criteria:
- Other coexisting retinal eye diseases (ARMD, Retinal Vein Occlusion, Uveitis, tractional retinal detachments involving or threatening macula).
- Any previous retinal laser, anti-VEGF, or intravitreal/suprachoroidal steroid in the study eye.
- History of any intraocular surgery less than 6 months or Yag Capsulotomy less than 3 months in the study eye.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:グループB
|
Participants will undergo single-session panretinal photocoagulation (PRP) using the PASCAL pattern scan laser system. A total of 2,200-3,000 laser spots will be applied to the peripheral retina. |
|
アクティブコンパレータ:グループA
|
Participants will undergo single-session panretinal photocoagulation (PRP) using the PASCAL pattern scan laser system. A total of 3,200-4,000 laser spots will be applied to the peripheral retina |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
Change in Central Macular Thickness
時間枠:4 weeks
|
4 weeks
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- CHR-IREB-2026-0134
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。