- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07950046
High- Versus Low-Density PASCAL Laser Treatment for Proliferative Diabetic Retinopathy
CENTRAL MACULAR THICKNESS AFTER HIGH- VERSUS LOW-DENSITY SINGLE-SESSION PATTERN SCAN LASER PANRETINAL PHOTOCOAGULATION IN PROLIFERATIVE DIABETIC RETINOPATHY: A RANDOMIZED NON-INFERIORITY TRIAL
This study aims to compare the effects of high-density and low-density single-session Pattern Scan Laser (PASCAL) panretinal photocoagulation (PRP) in patients with proliferative diabetic retinopathy (PDR).
Panretinal photocoagulation is a standard treatment for proliferative diabetic retinopathy. However, the number of laser spots applied during a single treatment session varies in clinical practice. This study will investigate whether applying a higher number of laser spots in one session is as safe and effective as applying a lower number of spots, particularly regarding changes in central macular thickness.
Eligible patients with proliferative diabetic retinopathy who have not previously received PRP will be randomly assigned to one of two groups. The low-density group will receive 2,200-3,000 laser spots, while the high-density group will receive 3,200-4,000 laser spots using the PASCAL laser system in a single session.
Central macular thickness will be measured using optical coherence tomography (OCT) before treatment and four weeks after treatment. The main purpose is to determine whether high-density PRP is not inferior to low-density PRP in terms of changes in central macular thickness. Visual acuity and treatment-related adverse effects will also be assessed.
The findings may help determine whether a higher number of laser spots can be safely delivered in a single PASCAL PRP session without causing an unacceptable increase in macular thickness.
연구 개요
상태
연구 유형
등록 (추정된)
단계
- 해당 없음
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
-
• Adults aged ≥ 18 years
- Type 1 or type 2 diabetes mellitus
- Treatment-naïve PDR with no clinically significant DME on OCT
- BCVA better than or equal to 6/60
- Baseline CMT <300 µm on Spectralis SD-OCT (central 1 mm ETDRS circle), with no intraretinal or subretinal fluid.
- Adequate pupil dilation and media clarity to perform OCT and laser photocoagulation
Exclusion Criteria:
- Other coexisting retinal eye diseases (ARMD, Retinal Vein Occlusion, Uveitis, tractional retinal detachments involving or threatening macula).
- Any previous retinal laser, anti-VEGF, or intravitreal/suprachoroidal steroid in the study eye.
- History of any intraocular surgery less than 6 months or Yag Capsulotomy less than 3 months in the study eye.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 더블
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
활성 비교기: 그룹 B
|
Participants will undergo single-session panretinal photocoagulation (PRP) using the PASCAL pattern scan laser system. A total of 2,200-3,000 laser spots will be applied to the peripheral retina. |
|
활성 비교기: 그룹 A
|
Participants will undergo single-session panretinal photocoagulation (PRP) using the PASCAL pattern scan laser system. A total of 3,200-4,000 laser spots will be applied to the peripheral retina |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
Change in Central Macular Thickness
기간: 4 weeks
|
4 weeks
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- CHR-IREB-2026-0134
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .