このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Clinical Outcomes of Digitally Recorded Mandibular Trajectories for Dynamic Occlusal Design in Full-Arch Implant Rehabilitation

2026年11月16日 更新者:Fuming He

Clinical Efficacy Evaluation of Mandibular Movement Trajectories Recorded by Different Digital Technologies for Dynamic Occlusal Design in Full-arch Implant Rehabilitation

  1. Research background: Digital workflows integrating precise modeling, virtual design and computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication have substantially improved restoration fit and clinical efficiency. Nevertheless, contemporary digital workflows still present limitations in occlusal reconstruction. Conventional CAD/CAM relies largely on static occlusal data points, which leads to mismatches between restorations and patients' actual functional mandibular pathways. Accordingly, dynamically guided occlusal reconstruction has become a key objective for enhancing the long-term stability and comfort of implant-supported rehabilitations. Particularly during the definitive restoration phase for edentulous patients, occlusal interactions between the implant superstructure and the opposing dentition exert a major influence on clinical chair time and patient satisfaction. Recently, high-precision digital mandibular motion analysis systems have emerged as effective solutions to address these challenges. Ultrasound-based mandibular tracking systems (e.g., Zebris JMA Optic) enable real-time capture of six-degrees-of-freedom mandibular movement and offer superior patient comfort compared with conventional electronic axiographic systems. Alternative technologies employ facial scanners to track spatial displacements of intraoral fiducial markers in real time. Meanwhile, facial scan data, dental cast scan data and CBCT data are registered and fused based on anterior dental anatomical landmarks, allowing direct visualization and recording of the true kinematic trajectories of the mandible and bilateral condyles on the three-dimensional CBCT model. This approach eliminates the need for a facebow or head-mounted apparatus and may provide improved comfort. The newly launched MetiSmile-MR/e-Motion platform by SHINING 3D acquires mandibular movement trajectories via the aforementioned multimodal data registration and fusion; however, its clinical performance in full-arch implant rehabilitation remains to be further validated.
  2. Research objective: This study aimed to evaluate the clinical efficacy of mandibular movement trajectories captured by two different digital technologies for dynamic occlusal design in maxillary full-arch implant rehabilitation. In addition, the potential benefits of these digitally recorded mandibular trajectories for dynamic occlusal design were assessed in terms of functional stability and patient satisfaction in full-arch implant rehabilitation, by examining mandibular pathways after definitive restoration delivery and patients' subjective comfort. Based on the above outcome measures, this study further evaluated whether the SHINING 3D multimodal data registration and fusion workflow could serve as an alternative to the electronic facebow for dynamic occlusal design in full-arch implant rehabilitation.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study..Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. For all included patients, at the definitive impression stage, mandibular movement trajectories were captured using two different digital technologies. The trajectory datasets obtained from both digital approaches were imported into Exocad software for the design of definitive restorations. After the definitive restorations were inserted intraorally, panoramic radiographs were taken to confirm complete seating of the restorations. The restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency. Once satisfactory occlusion was achieved, the restorations were rescanned to acquire post-adjustment digital models. A one-month follow-up visit after definitive restoration delivery was arranged to evaluate the stability of mandibular movement trajectories captured by the different digital workflows.

調査の概要

詳細な説明

  1. Research background: Digital workflows integrating precise modeling, virtual design and computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication have substantially improved restoration fit and clinical efficiency. Nevertheless, contemporary digital workflows still present limitations in occlusal reconstruction. Conventional CAD/CAM relies largely on static occlusal data points, which leads to mismatches between restorations and patients' actual functional mandibular pathways. Accordingly, dynamically guided occlusal reconstruction has become a key objective for enhancing the long-term stability and comfort of implant-supported rehabilitations. Particularly during the definitive restoration phase for edentulous patients, occlusal interactions between the implant superstructure and the opposing dentition exert a major influence on clinical chair time and patient satisfaction. Recently, high-precision digital mandibular motion analysis systems have emerged as effective solutions to address these challenges. Ultrasound-based mandibular tracking systems (e.g., Zebris JMA Optic) enable real-time capture of six-degrees-of-freedom mandibular movement and offer superior patient comfort compared with conventional electronic axiographic systems. Alternative technologies employ facial scanners to track spatial displacements of intraoral fiducial markers in real time. Meanwhile, facial scan data, dental cast scan data and CBCT data are registered and fused based on anterior dental anatomical landmarks, allowing direct visualization and recording of the true kinematic trajectories of the mandible and bilateral condyles on the three-dimensional CBCT model. This approach eliminates the need for a facebow or head-mounted apparatus and may provide improved comfort. The newly launched MetiSmile-MR/e-Motion platform by SHINING 3D acquires mandibular movement trajectories via the aforementioned multimodal data registration and fusion; however, its clinical performance in full-arch implant rehabilitation remains to be further validated.
  2. Research objective: This study aimed to evaluate the clinical efficacy of mandibular movement trajectories captured by two different digital technologies for dynamic occlusal design in maxillary full-arch implant rehabilitation. In addition, the potential benefits of these digitally recorded mandibular trajectories for dynamic occlusal design were assessed in terms of functional stability and patient satisfaction in full-arch implant rehabilitation, by examining mandibular pathways after definitive restoration delivery and patients' subjective comfort. Based on the above outcome measures, this study further evaluated whether the SHINING 3D multimodal data registration and fusion workflow could serve as an alternative to the electronic facebow for dynamic occlusal design in full-arch implant rehabilitation.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study..Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Patients meeting the inclusion criteria were recruited from the date of ethical approval until August 2028 at the Affiliated Stomatological Hospital, Zhejiang University School of Medicine. Eligible participants were edentulous patients who had received implant-supported full-arch provisional restorations and required definitive restorations. Patients were randomized into the Zebris electronic facebow group and the SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow group using a random number table. All participants provided written informed consent prior to enrollment. Baseline demographic information including sex, age, and edentulous status was documented. Outcome assessors were blinded to group allocation after treatment. Four to six implants were placed in the maxilla for each patient. A full-arch maxillary master impression was obtained immediately after surgery. Provisional restorations were fabricated and delivered on the same day with careful occlusal adjustment. During the healing period, which typically lasted 4-6 months, sequential adjustments of the provisional restorations were performed to achieve occlusal equilibrium and facilitate patient adaptation. At definitive impression taking, mandibular movement trajectories were captured using the two different digital technologies. Trajectory datasets acquired by both digital workflows were imported into Exocad design software. The dynamic occlusion module was activated during design to simulate mandibular movement pathways for virtual tooth arrangement and pre-fabrication occlusal refinement of the restorations. Upon design finalization, metal-free monolithic zirconia full-arch restorations were fabricated via CAD/CAM. After insertion of the definitive restorations, panoramic radiographs were acquired to verify complete seating of the restorations. The restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. Once satisfactory occlusion was achieved, the restorations were rescanned to obtain post-adjustment digital models. A 3D metrological analysis software package (Geomagic Control X 2022) was used for registration and analysis of the digital models obtained before and after occlusal grinding. Occlusal grinding depth (μm) was quantified and reported as the mean absolute error (MAE, representing the mean occlusal grinding depth) and root mean square (RMS) value; occlusal grinding area (mm²) was also calculated. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency. At the one-month follow-up after definitive restoration delivery, mandibular movement trajectories were remeasured once stable occlusion was confirmed. These measurements were compared with the baseline trajectories recorded during the provisional phase (after stabilization of the provisional restoration and prior to definitive restoration) to evaluate the stability of mandibular trajectories captured by the different digital workflows. The evaluated kinematic parameters included the protrusive condylar guidance inclination, lateral condylar guidance, protrusive incisal guidance inclination, and lateral incisal guidance inclination on the left and right sides. The visual analogue scale (VAS) was used to assess patient comfort during mandibular trajectory acquisition with the two digital approaches.

研究の種類

介入

入学 (推定)

24

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:Fuming He
  • 電話番号:+8613516817697
  • メール:hfm@zju.edu.cn

研究連絡先のバックアップ

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

説明

Inclusion Criteria:

  1. Edentulous patients or patients with end-stage periodontitis aged ≥ 18 years, whose oral conditions are suitable for fixed implant-supported full-arch rehabilitation.
  2. Absence of severe systemic diseases, including uncontrolled diabetes mellitus, severe hypertension, cardiac disease, or a history of craniomaxillofacial radiotherapy.
  3. Patients scheduled to receive fixed implant-supported maxillary full-arch rehabilitation, with or without simultaneous mandibular full-arch implant-supported fixed rehabilitation, and to be delivered with an acrylic resin maxillary full-arch provisional restoration within 24 h after surgery.
  4. Patients who are able to understand and actively cooperate with treatment procedures and have provided written informed consent.

Exclusion Criteria:

  1. Patients retaining acrylic resin restorations as definitive restorations.
  2. Patients unable to cooperate with the mandibular motion analysis system for mandibular movement trajectory capture.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
偽コンパレータ:Zebris electronic facebow group

At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

実験的:SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow group

At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow.

At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Occlusal Adjustment Depth and Area
時間枠:From enrollment

After insertion of the definitive restorations, the restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. Once satisfactory occlusion was achieved, the restorations were rescanned to obtain post-adjustment digital models. A 3D metrological analysis software package (Geomagic Control X 2022) was used for registration and analysis of the digital models obtained before and after occlusal grinding. Occlusal grinding depth (μm) was quantified and reported as the mean absolute error (MAE, representing the mean occlusal grinding depth) and root mean square (RMS) value; occlusal grinding area (mm²) was also calculated.

From enrollment

二次結果の測定

結果測定
メジャーの説明
時間枠
Occlusal Adjustment Time
時間枠:From enrollment

After insertion of the definitive restorations, the restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. Once satisfactory occlusion was achieved, the restorations were rescanned to obtain post-adjustment digital models. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency.

From enrollment
Stability of mandibular movement trajectories
時間枠:From enrollment

At the one-month follow-up after definitive restoration delivery, mandibular movement trajectories were remeasured once stable occlusion was confirmed. These measurements were compared with the baseline trajectories recorded during the provisional phase (after stabilization of the provisional restoration and prior to definitive restoration) to evaluate the stability of mandibular trajectories captured by the different digital workflows.

From enrollment
Patients' subjective comfort
時間枠:From enrollment

The visual analogue scale (VAS) was used to assess patient comfort during mandibular trajectory acquisition.

From enrollment

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年11月25日

一次修了 (推定)

2028年8月31日

研究の完了 (推定)

2028年11月30日

試験登録日

最初に提出

2026年11月16日

QC基準を満たした最初の提出物

2026年11月16日

最初の投稿 (実際)

2026年11月20日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月20日

QC基準を満たした最後の更新が送信されました

2026年11月16日

最終確認日

2026年11月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。