Clinical Outcomes of Digitally Recorded Mandibular Trajectories for Dynamic Occlusal Design in Full-Arch Implant Rehabilitation

maanantai 16. marraskuuta 2026 päivittänyt: Fuming He

Clinical Efficacy Evaluation of Mandibular Movement Trajectories Recorded by Different Digital Technologies for Dynamic Occlusal Design in Full-arch Implant Rehabilitation

  1. Research background: Digital workflows integrating precise modeling, virtual design and computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication have substantially improved restoration fit and clinical efficiency. Nevertheless, contemporary digital workflows still present limitations in occlusal reconstruction. Conventional CAD/CAM relies largely on static occlusal data points, which leads to mismatches between restorations and patients' actual functional mandibular pathways. Accordingly, dynamically guided occlusal reconstruction has become a key objective for enhancing the long-term stability and comfort of implant-supported rehabilitations. Particularly during the definitive restoration phase for edentulous patients, occlusal interactions between the implant superstructure and the opposing dentition exert a major influence on clinical chair time and patient satisfaction. Recently, high-precision digital mandibular motion analysis systems have emerged as effective solutions to address these challenges. Ultrasound-based mandibular tracking systems (e.g., Zebris JMA Optic) enable real-time capture of six-degrees-of-freedom mandibular movement and offer superior patient comfort compared with conventional electronic axiographic systems. Alternative technologies employ facial scanners to track spatial displacements of intraoral fiducial markers in real time. Meanwhile, facial scan data, dental cast scan data and CBCT data are registered and fused based on anterior dental anatomical landmarks, allowing direct visualization and recording of the true kinematic trajectories of the mandible and bilateral condyles on the three-dimensional CBCT model. This approach eliminates the need for a facebow or head-mounted apparatus and may provide improved comfort. The newly launched MetiSmile-MR/e-Motion platform by SHINING 3D acquires mandibular movement trajectories via the aforementioned multimodal data registration and fusion; however, its clinical performance in full-arch implant rehabilitation remains to be further validated.
  2. Research objective: This study aimed to evaluate the clinical efficacy of mandibular movement trajectories captured by two different digital technologies for dynamic occlusal design in maxillary full-arch implant rehabilitation. In addition, the potential benefits of these digitally recorded mandibular trajectories for dynamic occlusal design were assessed in terms of functional stability and patient satisfaction in full-arch implant rehabilitation, by examining mandibular pathways after definitive restoration delivery and patients' subjective comfort. Based on the above outcome measures, this study further evaluated whether the SHINING 3D multimodal data registration and fusion workflow could serve as an alternative to the electronic facebow for dynamic occlusal design in full-arch implant rehabilitation.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study..Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. For all included patients, at the definitive impression stage, mandibular movement trajectories were captured using two different digital technologies. The trajectory datasets obtained from both digital approaches were imported into Exocad software for the design of definitive restorations. After the definitive restorations were inserted intraorally, panoramic radiographs were taken to confirm complete seating of the restorations. The restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency. Once satisfactory occlusion was achieved, the restorations were rescanned to acquire post-adjustment digital models. A one-month follow-up visit after definitive restoration delivery was arranged to evaluate the stability of mandibular movement trajectories captured by the different digital workflows.

Tutkimuksen yleiskatsaus

Yksityiskohtainen kuvaus

  1. Research background: Digital workflows integrating precise modeling, virtual design and computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication have substantially improved restoration fit and clinical efficiency. Nevertheless, contemporary digital workflows still present limitations in occlusal reconstruction. Conventional CAD/CAM relies largely on static occlusal data points, which leads to mismatches between restorations and patients' actual functional mandibular pathways. Accordingly, dynamically guided occlusal reconstruction has become a key objective for enhancing the long-term stability and comfort of implant-supported rehabilitations. Particularly during the definitive restoration phase for edentulous patients, occlusal interactions between the implant superstructure and the opposing dentition exert a major influence on clinical chair time and patient satisfaction. Recently, high-precision digital mandibular motion analysis systems have emerged as effective solutions to address these challenges. Ultrasound-based mandibular tracking systems (e.g., Zebris JMA Optic) enable real-time capture of six-degrees-of-freedom mandibular movement and offer superior patient comfort compared with conventional electronic axiographic systems. Alternative technologies employ facial scanners to track spatial displacements of intraoral fiducial markers in real time. Meanwhile, facial scan data, dental cast scan data and CBCT data are registered and fused based on anterior dental anatomical landmarks, allowing direct visualization and recording of the true kinematic trajectories of the mandible and bilateral condyles on the three-dimensional CBCT model. This approach eliminates the need for a facebow or head-mounted apparatus and may provide improved comfort. The newly launched MetiSmile-MR/e-Motion platform by SHINING 3D acquires mandibular movement trajectories via the aforementioned multimodal data registration and fusion; however, its clinical performance in full-arch implant rehabilitation remains to be further validated.
  2. Research objective: This study aimed to evaluate the clinical efficacy of mandibular movement trajectories captured by two different digital technologies for dynamic occlusal design in maxillary full-arch implant rehabilitation. In addition, the potential benefits of these digitally recorded mandibular trajectories for dynamic occlusal design were assessed in terms of functional stability and patient satisfaction in full-arch implant rehabilitation, by examining mandibular pathways after definitive restoration delivery and patients' subjective comfort. Based on the above outcome measures, this study further evaluated whether the SHINING 3D multimodal data registration and fusion workflow could serve as an alternative to the electronic facebow for dynamic occlusal design in full-arch implant rehabilitation.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study..Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Patients meeting the inclusion criteria were recruited from the date of ethical approval until August 2028 at the Affiliated Stomatological Hospital, Zhejiang University School of Medicine. Eligible participants were edentulous patients who had received implant-supported full-arch provisional restorations and required definitive restorations. Patients were randomized into the Zebris electronic facebow group and the SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow group using a random number table. All participants provided written informed consent prior to enrollment. Baseline demographic information including sex, age, and edentulous status was documented. Outcome assessors were blinded to group allocation after treatment. Four to six implants were placed in the maxilla for each patient. A full-arch maxillary master impression was obtained immediately after surgery. Provisional restorations were fabricated and delivered on the same day with careful occlusal adjustment. During the healing period, which typically lasted 4-6 months, sequential adjustments of the provisional restorations were performed to achieve occlusal equilibrium and facilitate patient adaptation. At definitive impression taking, mandibular movement trajectories were captured using the two different digital technologies. Trajectory datasets acquired by both digital workflows were imported into Exocad design software. The dynamic occlusion module was activated during design to simulate mandibular movement pathways for virtual tooth arrangement and pre-fabrication occlusal refinement of the restorations. Upon design finalization, metal-free monolithic zirconia full-arch restorations were fabricated via CAD/CAM. After insertion of the definitive restorations, panoramic radiographs were acquired to verify complete seating of the restorations. The restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. Once satisfactory occlusion was achieved, the restorations were rescanned to obtain post-adjustment digital models. A 3D metrological analysis software package (Geomagic Control X 2022) was used for registration and analysis of the digital models obtained before and after occlusal grinding. Occlusal grinding depth (μm) was quantified and reported as the mean absolute error (MAE, representing the mean occlusal grinding depth) and root mean square (RMS) value; occlusal grinding area (mm²) was also calculated. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency. At the one-month follow-up after definitive restoration delivery, mandibular movement trajectories were remeasured once stable occlusion was confirmed. These measurements were compared with the baseline trajectories recorded during the provisional phase (after stabilization of the provisional restoration and prior to definitive restoration) to evaluate the stability of mandibular trajectories captured by the different digital workflows. The evaluated kinematic parameters included the protrusive condylar guidance inclination, lateral condylar guidance, protrusive incisal guidance inclination, and lateral incisal guidance inclination on the left and right sides. The visual analogue scale (VAS) was used to assess patient comfort during mandibular trajectory acquisition with the two digital approaches.

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

24

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskeluyhteys

  • Nimi: Fuming He
  • Puhelinnumero: +8613516817697
  • Sähköposti: hfm@zju.edu.cn

Tutki yhteystietojen varmuuskopiointi

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

18 vuotta ja vanhemmat (Aikuinen, Vanhempi Aikuinen)

Hyväksyy terveitä vapaaehtoisia

Joo

Sukupuolet, jotka voivat opiskella

Kaikki

Kuvaus

Inclusion Criteria:

  1. Edentulous patients or patients with end-stage periodontitis aged ≥ 18 years, whose oral conditions are suitable for fixed implant-supported full-arch rehabilitation.
  2. Absence of severe systemic diseases, including uncontrolled diabetes mellitus, severe hypertension, cardiac disease, or a history of craniomaxillofacial radiotherapy.
  3. Patients scheduled to receive fixed implant-supported maxillary full-arch rehabilitation, with or without simultaneous mandibular full-arch implant-supported fixed rehabilitation, and to be delivered with an acrylic resin maxillary full-arch provisional restoration within 24 h after surgery.
  4. Patients who are able to understand and actively cooperate with treatment procedures and have provided written informed consent.

Exclusion Criteria:

  1. Patients retaining acrylic resin restorations as definitive restorations.
  2. Patients unable to cooperate with the mandibular motion analysis system for mandibular movement trajectory capture.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Yksittäinen

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Huijausvertailija: Zebris electronic facebow group

At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

Kokeellinen: SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow group

At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow.

At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Occlusal Adjustment Depth and Area
Aikaikkuna: From enrollment

After insertion of the definitive restorations, the restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. Once satisfactory occlusion was achieved, the restorations were rescanned to obtain post-adjustment digital models. A 3D metrological analysis software package (Geomagic Control X 2022) was used for registration and analysis of the digital models obtained before and after occlusal grinding. Occlusal grinding depth (μm) was quantified and reported as the mean absolute error (MAE, representing the mean occlusal grinding depth) and root mean square (RMS) value; occlusal grinding area (mm²) was also calculated.

From enrollment

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Occlusal Adjustment Time
Aikaikkuna: From enrollment

After insertion of the definitive restorations, the restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. Once satisfactory occlusion was achieved, the restorations were rescanned to obtain post-adjustment digital models. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency.

From enrollment
Stability of mandibular movement trajectories
Aikaikkuna: From enrollment

At the one-month follow-up after definitive restoration delivery, mandibular movement trajectories were remeasured once stable occlusion was confirmed. These measurements were compared with the baseline trajectories recorded during the provisional phase (after stabilization of the provisional restoration and prior to definitive restoration) to evaluate the stability of mandibular trajectories captured by the different digital workflows.

From enrollment
Patients' subjective comfort
Aikaikkuna: From enrollment

The visual analogue scale (VAS) was used to assess patient comfort during mandibular trajectory acquisition.

From enrollment

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Sponsori

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Arvioitu)

Keskiviikko 25. marraskuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Torstai 31. elokuuta 2028

Opintojen valmistuminen (Arvioitu)

Torstai 30. marraskuuta 2028

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Maanantai 16. marraskuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Maanantai 16. marraskuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Perjantai 20. marraskuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Perjantai 20. marraskuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Maanantai 16. marraskuuta 2026

Viimeksi vahvistettu

Sunnuntai 1. marraskuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

EI

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa