Safety and Effectiveness of the Medtronic Resting Heart Bypass System in Heart Surgery Patients

2017년 8월 25일 업데이트: Lawson Health Research Institute

A Prospective Randomized Study of the Safety and Effectiveness of the Medtronic Resting Heart System

The purpose of this study is to determine if the Medtronic Resting Heart Bypass system is safer and results in less inflammatory reaction than traditional bypass machines used in coronary artery bypass surgery. We hypothesize that the new Medtronic Resting Heart System is safer and results in much less systemic inflammatory reaction in comparison to the standard cardiopulmonary bypass systems currently in use.

연구 개요

상세 설명

Cardiopulmonary bypass (CPB) has played an extremely crucial role in coronary artery bypass grafting (CABG) surgery for the past five decades. During CABG, the CPB machine enables the surgeon to stop the heart and perform the surgery in a bloodless operating field. The CPB machine essentially takes over the job of the heart by oxygenating the blood and then perfusing the entire body. In patients undergoing CABG surgery with CPB, a systemic inflammatory reaction occurs when the blood is taken out of the body and circulated through the CPB machine. This inflammatory reaction is believed to increase postoperative morbidity and prolong hospital stay. The systemic inflammatory reaction results in activation of the complement, coagulation, fibrinolytic and kallikrein cascades, it activates leukocytes and endothelial cells causing expression of adhesion molecules and results in the release of inflammatory mediators such as cytokines. This inflammatory reaction during CPB leads to vasodilation, increased interstitial fluid and can affect organs such as the heart, lungs, brain and kidneys resulting in their dysfunction(s). Elimination of CPB in patients undergoing CABG surgery has resulted in reduction of this inflammatory response. Unfortunately, not all patients are able to undergo CABG without the use of CPB.

Most conventional CPB systems also use cardiotomy suction which returns all the blood collected in the operative field back to the CPB reservoir and then eventually returns it to the patient. This blood is rich in inflammatory mediators and small particles because it has been activated by surgical trauma and by the proteins lining the wound cavity. Returning this blood back into the CPB circuit results in further circulation of inflammatory mediators. Removal of the cardiotomy suction from the CPB system could potentially decrease the inflammatory mediators and reduce the inflammatory response during CPB.

Recently, there have been attempts to decrease the inflammatory reaction caused by the use of CPB by developing better, more effective systems. The Medtronic Resting Heart System is very similar to conventional CPB systems and has been approved for clinical use both in Canada and the United States. It has some potential advantages over traditional bypass machines which include; 1)a fully closed-to-air system that does not allow an air-blood interface which could prevent blood activation, 2)it does not have cardiotomy suction and therefore prevents air, lipids or particulate emboli from being re-introduced into the patient's circulation, 3)it minimizes hemodilution by using smaller and low-prime circuits, possibly decreasing the need for postoperative blood transfusion, 4)the CPB circuit, which is the blood-contacting surface, is coated with Carmeda Bioactive Surface (a heparin bioactive surface), that mimics critical characteristics of vascular endothelium and may prevent further blood activation, and 5)it has an active venous air detector and removal device (VARD) that detects venous air and automatically removes the air which may prevent blood activation. All of these elements are potential benefits which may further reduce the morbidity and inflammation associated with CABG surgery.

Thus far to our knowledge, there have been no studies looking at the inflammatory reaction and morbidity in patients undergoing CABG procedures using more improved cardiopulmonary bypass machines. We are therefore proposing a prospective, randomized trial of the safety and effectiveness of the Medtronic Resting Heart system in CABG surgery.

연구 유형

중재적

등록

60

단계

  • 1단계

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Ontario
      • London, Ontario, 캐나다, N6A 5A5
        • London Health Sciences Centre, University Hospital

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

30년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Consenting patients undergoing elective surgical coronary artery bypass grafting (CABG) with use of the cardiopulmonary bypass machine

Exclusion Criteria:

  • Patients unable to provide written informed consent
  • Emergency CABG surgery
  • Concomitant CABG + Valvular surgery
  • Off-pump CABG surgery

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 하나의

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
C 반응성 단백질
Cell count
Cytokine levels
Complement

2차 결과 측정

결과 측정
Postoperative blood loss, units of blood transfused, re-operation for bleeding, chest tube drainage, length of ICU stay, neurologic and renal function, infection, atrial fibrillation and overall length of postoperative hospital stay

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2004년 11월 1일

기본 완료 (실제)

2005년 11월 1일

연구 완료 (실제)

2006년 2월 1일

연구 등록 날짜

최초 제출

2006년 3월 15일

QC 기준을 충족하는 최초 제출

2006년 3월 15일

처음 게시됨 (추정)

2006년 3월 17일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2017년 8월 28일

QC 기준을 충족하는 마지막 업데이트 제출

2017년 8월 25일

마지막으로 확인됨

2017년 8월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • R-04-424

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다