A Study Comparing the Sensed R Wave in Bipolar and Extended Bipolar Configurations (PropR)
2012년 2월 27일 업데이트: Saint Francis Care
Prospective Study Comparing the Sensed R Wave in Bipolar and Extended Bipolar Configurations
The PropR study will evaluate sensing during ventricular fibrillation (VF) in both bipolar and extended bipolar configurations, in order to evaluate if both can be used interchangeably in caring for patients.
In addition, follow up evaluation of R wave amplitude over time would allow us to determine whether one configuration is more likely to be associated with change.
This understanding would be important in selecting the proper configuration at the time of implant.
연구 개요
상세 설명
Hypothesis:
Sensing in bipolar and extended bipolar configurations are the same. However, sensing in bipolar over time is more likely to decrease when compared to extended bipolar.
Objectives:
- To compare bipolar sensing and extended bipolar sensing in VF.
- Compare sensing in bipolar and extended bipolar over time.
Methods:
- This study will be a randomized comparison of bipolar and extended bipolar sensing. As per usual standard of care, at the end of ICD implantation two sensing tests in VF will be performed. Patients will be randomized to sensing in VF through the device. Each patient will undergo testing in one randomized configuration followed by a second test in the other configuration. After testing at the time of implant, each patient will be seen at one month in follow up. Sensing of each configuration will be reevaluated at that time in sinus rhythm.
- Each patient will serve as their own control, as data for sensing in both configurations will be obtained in VF at the time of implant. During testing both signals types will be recorded simultaneously through the ICD. The primary endpoint will be duration of sensing (time to detection) in VF at the time of implant.
- The secondary endpoint will be sensing in sinus rhythm at one month.
- The patient population will include approximately 30-50 volunteers age >18, male and female, both ischemic and nonischemic cardiomyopathy, with primary and secondary implant indications.
- Patients will be recruited when being evaluated for defibrillator implant.
- Inclusion criteria: age >18 with ability to give informed consent, who are expected to live more than one year, with indication for defibrillator implant and who are not pacemaker dependent. Patients will have either ischemic or nonischemic cardiomyopathy.
- Exclusion criteria: age <18, inability to give informed consent, or life expectancy less than one year, pacemaker dependence, or use of preexisting lead for sensing, any condition which would preclude ICD testing at the end of the implant. Patients who are undergoing upgrade to an ICD from a pacemaker will also be excluded. In addition, patients with inherited arrhythmias or ion channel related arrhythmias will be excluded from the study.
- Withdrawal criteria: inability to implant device, implant lead at the RV apex, or make follow up appointment (living out of state), patient death at time of implant, elevated DFT (<10 J margin between DFT and maximum output of the device) requiring additional procedures, subcutaneous array etc.
- Duration of patient participation would be one month.
- Duration of study would be one year.
Procedures:
- Procedures to be followed would include screening of all eligible patients undergoing implant of a Medtronic defibrillator for either primary or secondary prevention. If patients meet inclusion criteria they would then undergo informed consent and if willing be enrolled in the study. Defibrillator implant and testing would be performed as per usual practice of the implanting physician. The RV lead will be placed at the RV apex as is usual for regular implantation of devices. However, if a lead is placed elsewhere, the patient will need to be withdrawn from the study.
- When VF induction is performed, sensing configuration would be tested in a randomized fashion, unblinded to the operator. The untested configuration would then be tested during second VF induction. Both tests would be performed at a sensitivity setting of 1.2mV, with a number of intervals to detection (NID) of 24/32. Final programming polarity will be left at the initially tested polarity (first DFT test), unless the operator sees a need to program differently for patient safety reasons.
- Medtronic defibrillators with both sensing configurations available will be used. Data collection will be performed by Dr. Tolat, Dr. Berns, Dr. Lippman, Dr. Dell'Orfano, and the study coordinator involved with the study. A data collection form and spreadsheet will be kept for use when collecting data for analysis. Follow up will be performed at one month post implant in the office.
Risk Analysis:
- Anticipated risks are no more than that anticipated with usual ICD implant. To date, usual implant includes induction of VF with analysis of sensing in VF and evaluation of defibrillation threshold by delivery of shock.
- There is no expected increased exposure to risk by performing this study.
- Potential benefits would include gathering additional information on sensing in VF in both configurations instead of performing the two sensing tests in one configuration. This may directly benefit the patient by allowing for reprogramming defibrillator without bringing the patient back to the hospital for further testing.
Data Analysis:
- Data collection will include patient information kept in a database with name kept confidential. Patients will only be identified by number in keeping with privacy laws and practice. In addition to usual patient characteristics, data variables to be collected in both configurations will include: R wave amplitude in sinus rhythm, time to detection in VF, total episode duration (time to Vfib detection and charge delivered), number of "drop outs" (undersensing) in VF, and follow up R wave amplitude in one month.
- Statistical Methods will compare bipolar sensing configuration to the extended bipolar configuration at baseline, sensing in VF (as measured by "drop out", time to detection), and follow up amplitude of the R wave at one month.
- The current expected sample size with this pilot study is 30 patients. This may require reevaluation depending on results at the time of interim analysis.
연구 유형
관찰
등록 (실제)
50
연락처 및 위치
이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.
연구 장소
-
-
Connecticut
-
Hartford, Connecticut, 미국, 06105
- St Francis Hospital and Medical Center
-
-
참여기준
연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.
자격 기준
공부할 수 있는 나이
18년 이상 (성인, 고령자)
건강한 자원 봉사자를 받아들입니다
아니
연구 대상 성별
모두
샘플링 방법
비확률 샘플
연구 인구
The patient population will include approximately 30-50 volunteers age >18, male and female, both ischemic and nonischemic cardiomyopathy, with primary and secondary implant indications.
설명
Inclusion Criteria:
- age > 18 with ability to give informed consent,
- patients who are expected to live more than one year,
- patients with indication for defibrillator implant,
- patients who are not pacemaker dependent,
- patients with either ischemic or nonischemic cardiomyopathy.
Exclusion Criteria:
- age < 18,
- inability to give informed consent,
- life expectancy less than one year,
- pacemaker dependence, or use of preexisting lead for sensing,
- any condition which would preclude ICD testing at the end of the implant,
- patients who are undergoing upgrade to an ICD from a pacemaker will also be excluded,
- patients with inherited arrhythmias or ion channel related arrhythmias will be excluded from the study.
공부 계획
이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
|---|
|
cardiomyopathy, with implant indications
30-50 volunteers age >18, male and female with ability to give informed consent, who are expected to live more than one year, with indication for defibrillator implant and who are not pacemaker dependent.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
Duration of sensing (time to detection) in VF at the time of implant.
기간: At implant
|
At implant
|
2차 결과 측정
결과 측정 |
기간 |
|---|---|
|
Sensing in sinus rhythm at one month
기간: One month post implant
|
One month post implant
|
공동 작업자 및 조사자
여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.
협력자
수사관
- 수석 연구원: Aneesh Tolat, MD, Attending Cardiac Electrophysiologist, St Francis Hospital and Medical Center
연구 기록 날짜
이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.
연구 주요 날짜
연구 시작
2009년 12월 1일
기본 완료 (실제)
2011년 7월 1일
연구 완료 (실제)
2011년 7월 1일
연구 등록 날짜
최초 제출
2009년 12월 14일
QC 기준을 충족하는 최초 제출
2009년 12월 14일
처음 게시됨 (추정)
2009년 12월 15일
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
2012년 2월 28일
QC 기준을 충족하는 마지막 업데이트 제출
2012년 2월 27일
마지막으로 확인됨
2012년 2월 1일
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- 10-01-005-E
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .