- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07668193
GlaukomAI: Clinical Validation of an AI System for Early Glaucoma Screening (GlaukomAIcare)
GlaukomAI: Clinical Validation of an Artificial Intelligence-Based System for Early Glaucoma Screening and Diagnosis - A Case-Control Study and Referral Accuracy Assessment
Glaucoma is one of the leading causes of irreversible blindness worldwide. Early diagnosis is crucial to prevent vision loss, but current diagnostic pathways require multiple specialist visits and tests, leading to long waiting times and delayed diagnosis.
This study aims to evaluate the accuracy of GlaukomAI, an artificial intelligence (AI)-based software that analyzes fundus photographs of the eye to detect glaucoma at an early stage.
The study is conducted at IRCCS Fondazione G. B. Bietti (Rome, Italy) and is structured in two phases:
- Phase 1 enrolls 200 participants (100 with diagnosed glaucoma and 100 healthy controls) to assess how accurately GlaukomAI can distinguish between glaucoma and healthy eyes, compared to the judgment of a panel of three expert glaucoma specialists.
- Phase 2 enrolls 1,000 consecutive outpatients to evaluate whether GlaukomAI can correctly identify patients who need referral to a glaucoma specialist, and to compare its performance with that of non-specialist ophthalmologists.
Participants undergo a single study visit including standard ophthalmic examinations (visual acuity, eye pressure measurement, visual field test, OCT, and fundus photography). No investigational drugs or invasive procedures are involved.
The results of this study will provide evidence to support the integration of AI-based tools into routine glaucoma screening pathways, with the goal of reducing diagnostic delays and improving access to care.
연구 개요
상세 설명
Glaucoma is a chronic optic neuropathy representing one of the leading causes of irreversible blindness worldwide, with an estimated 111.8 million cases projected by 2040. Despite the availability of effective treatments, approximately 50% of affected individuals remain undiagnosed, as the disease progresses insidiously and symptoms often appear only when damage is already advanced and irreversible.
Current diagnostic limitations include high inter-operator variability in optic disc assessment, limited sensitivity of visual field testing in early stages, and suboptimal specificity of OCT (estimated at 72% in a Cochrane systematic review). No single examination provides sufficient diagnostic accuracy, accessibility, and cost-effectiveness for large-scale screening.
GlaukomAI (Sens-vue GlaukomAI) is an AI-based diagnostic software using deep learning with Convolutional Neural Network and Transformer architecture. It analyzes standard fundus photographs to detect key glaucoma biomarkers (neuroretinal rim appearance, inferior and superior sectors) and provides a diagnostic classification (Referable Glaucoma / Non-Referable Glaucoma) within 2-8 seconds per image. The system was trained on over 100,000 fundus images from diverse ethnicities, annotated by 30 eye care professionals and validated by 243 ophthalmologists and 208 optometrists across Europe.
Study Design
This is a prospective interventional clinical investigation with a non-CE-marked medical device, structured in two complementary phases:
- Phase 1 - Case-Control Diagnostic Accuracy Study: 200 participants (100 with diagnosed glaucoma, 100 healthy controls) are enrolled to assess the sensitivity and specificity of GlaukomAI against a gold standard defined by the consensus of a panel of three expert glaucoma specialists, based on multimodal assessment (fundus photography, OCT, and visual field).
- Phase 2 - Prospective Referral Accuracy Assessment: 1,000 consecutive outpatients attending IRCCS Fondazione Bietti for any clinical reason are enrolled to evaluate the referral accuracy of GlaukomAI (binary output: Referable / Non-Referable) in a real-world setting, and to compare its performance with that of non-glaucoma-specialist ophthalmologists evaluating the same pseudonymized fundus images.
All participants undergo a single study visit (or two visits within one week if needed) including: best-corrected visual acuity measurement, slit-lamp biomicroscopy, Goldmann applanation tonometry, Humphrey visual field testing (24-2 SITA Standard or SITA Faster), fundus examination with Cup-to-Disc Ratio assessment, fundus photography using a widefield TrueColor Confocal imaging system (iCare DRS Plus), and retinal nerve fiber layer (RNFL) and ganglion cell layer (GCL+IPL) thickness assessment via Cirrus HD-OCT (Carl Zeiss). No investigational drugs or invasive procedures beyond standard clinical practice are involved.
Statistical Analysis For Phase 1, sample size was calculated to detect an expected sensitivity and specificity of 88% with 95% confidence and ±8% precision, yielding 100 subjects per group. For Phase 2, enrollment of 1,000 patients allows estimation of real-world sensitivity and specificity with ±5% precision, assuming a 10% glaucoma prevalence in a tertiary referral center. Both eyes will be included in the analysis using generalized estimating equations (GEE) or mixed-effects models to account for intra-subject correlation. Diagnostic performance metrics (sensitivity, specificity, PPV, NPV, AUC) will be calculated with 95% confidence intervals. Agreement between methods will be assessed using Cohen's kappa; comparisons will use McNemar's test.
Funding This study is funded under the Transforming Health and Care Systems (THCS) partnership, co-funded by the EU Horizon Europe Research and Innovation Programme (Grant Agreement No. 101095654).
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Francesco Oddone, MD, PhD
- 전화번호: +39 06 84009442
- 이메일: francesco.oddone@fondazionebietti.it
연구 연락처 백업
- 이름: Carmela Carnevale, MD
- 전화번호: +39 06 84009442
- 이메일: carmela.carnevale@fondazionebietti.it
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria for all patients:
- Age >18 years
- Freely given informed consent obtained prior to study initiation
- The participant has the capacity to understand and the willingness to follow study instructions and is likely to complete all required visits and procedures
Inclusion Criteria for glaucoma patients:
Patients affected by any type of glaucoma (primary open-angle, primary angle-closure, secondary glaucoma) on pharmacological therapy
Inclusion Criteria for healthy controls:
- Absence of ocular pathologies
- IOP <21 mmHg
- Visual field and OCT within normal limits
- Optic disc of normal appearance on clinical evaluation
Exclusion Criteria:
- Presence of media opacities preventing the acquisition of adequate quality fundus imaging (e.g., advanced cataract, vitreous hemorrhage, severe corneal opacities)
- Retinal or optic nerve pathologies that could confound the diagnosis (e.g., non-glaucomatous optic neuropathies (ischemic, inflammatory, compressive), moderate-to-severe diabetic retinopathy, advanced macular degeneration, retinal vascular occlusions)
- Having undergone any ocular surgery in the past 3 months
- Inability to cooperate with perimetric examination
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 특수 증상
- 할당: 무작위화되지 않음
- 중재 모델: 단일 그룹 할당
- 마스킹: 더블
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
다른: Glaucoma Patients
Participants with diagnosed glaucoma (primary open-angle, primary angle-closure or secondary glaucoma) undergoing standard ophthalmological examination and AI-based image analysis.
|
GlaukomAI is an AI-based diagnostic software (Sens-vue ApS) that analyzes standard fundus photographs to detect glaucomatous changes.
The system uses deep learning with Convolutional Neural Network and Transformer architecture to evaluate key glaucoma biomarkers, including neuroretinal rim appearance in the inferior and superior sectors.
It accepts standard fundus images acquired with conventional fundus cameras or portable devices and provides a diagnostic classification (Referable Glaucoma / Non-Referable Glaucoma) within 2-8 seconds per image.
The system is not CE-marked.
Fundus images are acquired using a widefield TrueColor Confocal fundus imaging system (iCare DRS Plus), pseudonymized, and uploaded to the GlaukomAI secure platform by an operator blinded to the clinical diagnosis.
|
|
다른: Healthy Controls
Participants without ocular pathology and with normal ophthalmological examination undergoing standard ophthalmological examination and AI-based image analysis.
|
GlaukomAI is an AI-based diagnostic software (Sens-vue ApS) that analyzes standard fundus photographs to detect glaucomatous changes.
The system uses deep learning with Convolutional Neural Network and Transformer architecture to evaluate key glaucoma biomarkers, including neuroretinal rim appearance in the inferior and superior sectors.
It accepts standard fundus images acquired with conventional fundus cameras or portable devices and provides a diagnostic classification (Referable Glaucoma / Non-Referable Glaucoma) within 2-8 seconds per image.
The system is not CE-marked.
Fundus images are acquired using a widefield TrueColor Confocal fundus imaging system (iCare DRS Plus), pseudonymized, and uploaded to the GlaukomAI secure platform by an operator blinded to the clinical diagnosis.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Diagnostic Accuracy of GlaukomAI - Sensitivity and Specificity
기간: At enrollment visit (single visit, or two consecutive visits within 1 week)
|
Sensitivity and specificity of GlaukomAI in the diagnosis of glaucoma, calculated against the gold standard defined by the consensus of a panel of three expert glaucoma specialists based on multimodal assessment (fundus photography, OCT, and visual field).
Additional metrics include positive predictive value (PPV), negative predictive value (NPV), and area under the ROC curve (AUC) with 95% confidence intervals.
The optimal diagnostic cut-off will be identified using the Youden index.
|
At enrollment visit (single visit, or two consecutive visits within 1 week)
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Referral Accuracy of GlaukomAI vs. Non-Specialist Ophthalmologists
기간: At enrollment visit
|
Sensitivity and specificity of GlaukomAI in recommending referral to a glaucoma specialist (binary output: Referable / Non-Referable), compared to the gold standard and to the independent referral decisions of non-glaucoma-specialist ophthalmologists evaluating the same pseudonymized fundus images.
|
At enrollment visit
|
|
Diagnostic Agreement - Cohen's Kappa
기간: At enrollment visit
|
Diagnostic agreement between GlaukomAI and the gold standard, and between non-glaucoma-specialist ophthalmologists and the gold standard, assessed using Cohen's kappa coefficient (κ).
Comparison between diagnostic methods on the same subjects will be performed using McNemar's test.
|
At enrollment visit
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Francesco Oddone, MD, PhD, IRCCS Fondazione G. B. Bietti, Rome, Italy
간행물 및 유용한 링크
일반 간행물
- Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology. 2014 Nov;121(11):2081-90. doi: 10.1016/j.ophtha.2014.05.013. Epub 2014 Jun 26.
- Oddone F, Lucenteforte E, Michelessi M, Rizzo S, Donati S, Parravano M, Virgili G. Macular versus Retinal Nerve Fiber Layer Parameters for Diagnosing Manifest Glaucoma: A Systematic Review of Diagnostic Accuracy Studies. Ophthalmology. 2016 May;123(5):939-49. doi: 10.1016/j.ophtha.2015.12.041. Epub 2016 Feb 15.
- Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol. 2006 Mar;90(3):262-7. doi: 10.1136/bjo.2005.081224.
- Li Z, He Y, Keel S, Meng W, Chang RT, He M. Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs. Ophthalmology. 2018 Aug;125(8):1199-1206. doi: 10.1016/j.ophtha.2018.01.023. Epub 2018 Mar 2.
- Lemij HG, Vente C, Sanchez CI, Vermeer KA. Characteristics of a Large, Labeled Data Set for the Training of Artificial Intelligence for Glaucoma Screening with Fundus Photographs. Ophthalmol Sci. 2023 Mar 17;3(3):100300. doi: 10.1016/j.xops.2023.100300. eCollection 2023 Sep.
- Michelessi M, Quaranta L, Riva I, Martini E, Figus M, Frezzotti P, Agnifili L, Manni G, Miglior S, Posarelli C, Fazio S, Oddone F. Exploring the gap between diagnostic research outputs and clinical use of OCT for diagnosing glaucoma. Br J Ophthalmol. 2020 Aug;104(8):1114-1119. doi: 10.1136/bjophthalmol-2019-314607. Epub 2019 Nov 15.
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- GLC 02-26
- 101095654 (기타 보조금/기금 번호: EU Horizon Europe Research and Innovation Programme)
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .