Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

GlaukomAI: Clinical Validation of an AI System for Early Glaucoma Screening (GlaukomAIcare)

2 september 2026 bijgewerkt door: Fondazione G.B. Bietti, IRCCS

GlaukomAI: Clinical Validation of an Artificial Intelligence-Based System for Early Glaucoma Screening and Diagnosis - A Case-Control Study and Referral Accuracy Assessment

Glaucoma is one of the leading causes of irreversible blindness worldwide. Early diagnosis is crucial to prevent vision loss, but current diagnostic pathways require multiple specialist visits and tests, leading to long waiting times and delayed diagnosis.

This study aims to evaluate the accuracy of GlaukomAI, an artificial intelligence (AI)-based software that analyzes fundus photographs of the eye to detect glaucoma at an early stage.

The study is conducted at IRCCS Fondazione G. B. Bietti (Rome, Italy) and is structured in two phases:

  • Phase 1 enrolls 200 participants (100 with diagnosed glaucoma and 100 healthy controls) to assess how accurately GlaukomAI can distinguish between glaucoma and healthy eyes, compared to the judgment of a panel of three expert glaucoma specialists.
  • Phase 2 enrolls 1,000 consecutive outpatients to evaluate whether GlaukomAI can correctly identify patients who need referral to a glaucoma specialist, and to compare its performance with that of non-specialist ophthalmologists.

Participants undergo a single study visit including standard ophthalmic examinations (visual acuity, eye pressure measurement, visual field test, OCT, and fundus photography). No investigational drugs or invasive procedures are involved.

The results of this study will provide evidence to support the integration of AI-based tools into routine glaucoma screening pathways, with the goal of reducing diagnostic delays and improving access to care.

Studie Overzicht

Toestand

Nog niet aan het werven

Conditie

Gedetailleerde beschrijving

Glaucoma is a chronic optic neuropathy representing one of the leading causes of irreversible blindness worldwide, with an estimated 111.8 million cases projected by 2040. Despite the availability of effective treatments, approximately 50% of affected individuals remain undiagnosed, as the disease progresses insidiously and symptoms often appear only when damage is already advanced and irreversible.

Current diagnostic limitations include high inter-operator variability in optic disc assessment, limited sensitivity of visual field testing in early stages, and suboptimal specificity of OCT (estimated at 72% in a Cochrane systematic review). No single examination provides sufficient diagnostic accuracy, accessibility, and cost-effectiveness for large-scale screening.

GlaukomAI (Sens-vue GlaukomAI) is an AI-based diagnostic software using deep learning with Convolutional Neural Network and Transformer architecture. It analyzes standard fundus photographs to detect key glaucoma biomarkers (neuroretinal rim appearance, inferior and superior sectors) and provides a diagnostic classification (Referable Glaucoma / Non-Referable Glaucoma) within 2-8 seconds per image. The system was trained on over 100,000 fundus images from diverse ethnicities, annotated by 30 eye care professionals and validated by 243 ophthalmologists and 208 optometrists across Europe.

Study Design

This is a prospective interventional clinical investigation with a non-CE-marked medical device, structured in two complementary phases:

  • Phase 1 - Case-Control Diagnostic Accuracy Study: 200 participants (100 with diagnosed glaucoma, 100 healthy controls) are enrolled to assess the sensitivity and specificity of GlaukomAI against a gold standard defined by the consensus of a panel of three expert glaucoma specialists, based on multimodal assessment (fundus photography, OCT, and visual field).
  • Phase 2 - Prospective Referral Accuracy Assessment: 1,000 consecutive outpatients attending IRCCS Fondazione Bietti for any clinical reason are enrolled to evaluate the referral accuracy of GlaukomAI (binary output: Referable / Non-Referable) in a real-world setting, and to compare its performance with that of non-glaucoma-specialist ophthalmologists evaluating the same pseudonymized fundus images.

All participants undergo a single study visit (or two visits within one week if needed) including: best-corrected visual acuity measurement, slit-lamp biomicroscopy, Goldmann applanation tonometry, Humphrey visual field testing (24-2 SITA Standard or SITA Faster), fundus examination with Cup-to-Disc Ratio assessment, fundus photography using a widefield TrueColor Confocal imaging system (iCare DRS Plus), and retinal nerve fiber layer (RNFL) and ganglion cell layer (GCL+IPL) thickness assessment via Cirrus HD-OCT (Carl Zeiss). No investigational drugs or invasive procedures beyond standard clinical practice are involved.

Statistical Analysis For Phase 1, sample size was calculated to detect an expected sensitivity and specificity of 88% with 95% confidence and ±8% precision, yielding 100 subjects per group. For Phase 2, enrollment of 1,000 patients allows estimation of real-world sensitivity and specificity with ±5% precision, assuming a 10% glaucoma prevalence in a tertiary referral center. Both eyes will be included in the analysis using generalized estimating equations (GEE) or mixed-effects models to account for intra-subject correlation. Diagnostic performance metrics (sensitivity, specificity, PPV, NPV, AUC) will be calculated with 95% confidence intervals. Agreement between methods will be assessed using Cohen's kappa; comparisons will use McNemar's test.

Funding This study is funded under the Transforming Health and Care Systems (THCS) partnership, co-funded by the EU Horizon Europe Research and Innovation Programme (Grant Agreement No. 101095654).

Studietype

Ingrijpend

Inschrijving (Geschat)

1200

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Contact Back-up

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Ja

Beschrijving

Inclusion Criteria for all patients:

  • Age >18 years
  • Freely given informed consent obtained prior to study initiation
  • The participant has the capacity to understand and the willingness to follow study instructions and is likely to complete all required visits and procedures

Inclusion Criteria for glaucoma patients:

Patients affected by any type of glaucoma (primary open-angle, primary angle-closure, secondary glaucoma) on pharmacological therapy

Inclusion Criteria for healthy controls:

  • Absence of ocular pathologies
  • IOP <21 mmHg
  • Visual field and OCT within normal limits
  • Optic disc of normal appearance on clinical evaluation

Exclusion Criteria:

  • Presence of media opacities preventing the acquisition of adequate quality fundus imaging (e.g., advanced cataract, vitreous hemorrhage, severe corneal opacities)
  • Retinal or optic nerve pathologies that could confound the diagnosis (e.g., non-glaucomatous optic neuropathies (ischemic, inflammatory, compressive), moderate-to-severe diabetic retinopathy, advanced macular degeneration, retinal vascular occlusions)
  • Having undergone any ocular surgery in the past 3 months
  • Inability to cooperate with perimetric examination

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Diagnostisch
  • Toewijzing: Niet-gerandomiseerd
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Dubbele

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Ander: Glaucoma Patients
Participants with diagnosed glaucoma (primary open-angle, primary angle-closure or secondary glaucoma) undergoing standard ophthalmological examination and AI-based image analysis.
GlaukomAI is an AI-based diagnostic software (Sens-vue ApS) that analyzes standard fundus photographs to detect glaucomatous changes. The system uses deep learning with Convolutional Neural Network and Transformer architecture to evaluate key glaucoma biomarkers, including neuroretinal rim appearance in the inferior and superior sectors. It accepts standard fundus images acquired with conventional fundus cameras or portable devices and provides a diagnostic classification (Referable Glaucoma / Non-Referable Glaucoma) within 2-8 seconds per image. The system is not CE-marked. Fundus images are acquired using a widefield TrueColor Confocal fundus imaging system (iCare DRS Plus), pseudonymized, and uploaded to the GlaukomAI secure platform by an operator blinded to the clinical diagnosis.
Ander: Healthy Controls
Participants without ocular pathology and with normal ophthalmological examination undergoing standard ophthalmological examination and AI-based image analysis.
GlaukomAI is an AI-based diagnostic software (Sens-vue ApS) that analyzes standard fundus photographs to detect glaucomatous changes. The system uses deep learning with Convolutional Neural Network and Transformer architecture to evaluate key glaucoma biomarkers, including neuroretinal rim appearance in the inferior and superior sectors. It accepts standard fundus images acquired with conventional fundus cameras or portable devices and provides a diagnostic classification (Referable Glaucoma / Non-Referable Glaucoma) within 2-8 seconds per image. The system is not CE-marked. Fundus images are acquired using a widefield TrueColor Confocal fundus imaging system (iCare DRS Plus), pseudonymized, and uploaded to the GlaukomAI secure platform by an operator blinded to the clinical diagnosis.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Diagnostic Accuracy of GlaukomAI - Sensitivity and Specificity
Tijdsspanne: At enrollment visit (single visit, or two consecutive visits within 1 week)
Sensitivity and specificity of GlaukomAI in the diagnosis of glaucoma, calculated against the gold standard defined by the consensus of a panel of three expert glaucoma specialists based on multimodal assessment (fundus photography, OCT, and visual field). Additional metrics include positive predictive value (PPV), negative predictive value (NPV), and area under the ROC curve (AUC) with 95% confidence intervals. The optimal diagnostic cut-off will be identified using the Youden index.
At enrollment visit (single visit, or two consecutive visits within 1 week)

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Referral Accuracy of GlaukomAI vs. Non-Specialist Ophthalmologists
Tijdsspanne: At enrollment visit
Sensitivity and specificity of GlaukomAI in recommending referral to a glaucoma specialist (binary output: Referable / Non-Referable), compared to the gold standard and to the independent referral decisions of non-glaucoma-specialist ophthalmologists evaluating the same pseudonymized fundus images.
At enrollment visit
Diagnostic Agreement - Cohen's Kappa
Tijdsspanne: At enrollment visit
Diagnostic agreement between GlaukomAI and the gold standard, and between non-glaucoma-specialist ophthalmologists and the gold standard, assessed using Cohen's kappa coefficient (κ). Comparison between diagnostic methods on the same subjects will be performed using McNemar's test.
At enrollment visit

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Francesco Oddone, MD, PhD, IRCCS Fondazione G. B. Bietti, Rome, Italy

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Algemene publicaties

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Geschat)

1 oktober 2026

Primaire voltooiing (Geschat)

1 november 2027

Studie voltooiing (Geschat)

1 mei 2028

Studieregistratiedata

Eerst ingediend

19 juni 2026

Eerst ingediend dat voldeed aan de QC-criteria

19 juni 2026

Eerst geplaatst (Werkelijk)

25 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

4 september 2026

Laatste update ingediend die voldeed aan QC-criteria

2 september 2026

Laatst geverifieerd

1 september 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • GLC 02-26
  • 101095654 (Ander subsidie-/financieringsnummer: EU Horizon Europe Research and Innovation Programme)

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren