이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

REstoration of SYNChronous Cardiac Function Due to Physiologic cArdiac Pacing Modalities With Clinical Endpoints (RESYNC-PACE)

2026년 7월 8일 업데이트: Peter Ezer, University of Pecs

REstoration of SYNChronous Cardiac Function Due to Physiologic cArdiac Pacing Modalities With Clinical Endpoints RESYNC-PACE

The goal of this observational study is to evaluate the long-term clinical outcomes of physiologic cardiac resynchronization therapy (CRT) using conduction system pacing strategies compared with conventional biventricular CRT in patients with heart failure with reduced ejection fraction (HFrEF) and electrical dyssynchrony.

The main questions it aims to answer are:

  • Does physiologic CRT (including left bundle branch area pacing [LBBAP] and LBBAP-optimized CRT) reduce the combined risk of all-cause mortality and heart failure hospitalization compared with conventional biventricular CRT?
  • Does physiologic CRT improve cardiac function and reverse ventricular remodeling more effectively than conventional CRT?

Participants receiving physiologic CRT as part of routine clinical care will undergo standard follow-up evaluations, including electrocardiography, echocardiography, laboratory testing, and device interrogation. Clinical outcomes will be collected prospectively for 24 months and compared with a historical cohort of patients treated with conventional biventricular CRT.

The study will assess clinical outcomes, echocardiographic response, electrical resynchronization parameters, and device-related safety in a real-world heart failure population.

연구 개요

상세 설명

Background

Heart failure with reduced ejection fraction (HFrEF) is associated with substantial morbidity, mortality, and healthcare utilization despite continuous advances in guideline-directed medical therapy. Cardiac resynchronization therapy (CRT) has become an established treatment for patients with symptomatic HFrEF and electrical dyssynchrony. Conventional biventricular pacing improves ventricular synchrony and clinical outcomes; however, approximately one-third of treated patients do not achieve a satisfactory response.

Conduction system pacing (CSP), particularly left bundle branch area pacing (LBBAP), has emerged as a physiological pacing strategy capable of directly engaging the native His-Purkinje conduction system. Compared with conventional biventricular pacing, CSP may produce more physiological ventricular activation, narrower paced QRS complexes, improved electrical synchrony, and greater reverse ventricular remodeling. Nevertheless, evidence regarding its long-term effectiveness in routine clinical practice remains limited, particularly in heterogeneous populations with different conduction abnormalities.

Study Rationale

The RESYNC-PACE study was designed to evaluate the effectiveness of individualized physiologic cardiac resynchronization strategies in a real-world population of patients with HFrEF requiring CRT.

The study investigates two complementary physiologic CRT approaches according to the underlying conduction disturbance. In patients with typical left bundle branch block (LBBB), left ventricular lead implantation is guided by the qLV ratio to achieve optimal electrical resynchronization through individualized coronary sinus lead positioning. In patients with intraventricular conduction delay (IVCD), a conduction system pacing strategy is applied using left bundle branch area pacing. When conduction system pacing alone results in incomplete electrical correction, defined by a paced QRS duration greater than 130 ms, an additional coronary sinus left ventricular lead is implanted to establish Left Bundle Branch Area Pacing Optimized Cardiac Resynchronization Therapy (LOT-CRT).

This individualized treatment algorithm reflects contemporary physiological concepts of ventricular resynchronization rather than a single implantation strategy and represents the principal scientific concept investigated in the study.

Scientific Objectives

The study aims to determine whether physiologic CRT strategies provide superior long-term clinical outcomes compared with conventional biventricular CRT when implemented in routine clinical practice.

In addition to evaluating clinical outcomes, the study investigates the relationship between electrical resynchronization, ventricular reverse remodeling, myocardial scar characteristics assessed by cardiac magnetic resonance imaging, and long-term prognosis. Particular emphasis is placed on identifying imaging-, electrocardiographic-, and device-derived predictors of CRT response that may facilitate patient selection and optimization of resynchronization therapy.

Study Methodology

RESYNC-PACE is a single-center, ambispective observational cohort study performed at the University of Pécs Clinical Centre Heart Institute. Consecutive patients undergoing physiologic CRT constitute the prospective cohort, while a historical cohort of patients treated with conventional biventricular CRT serves as the comparator.

All therapeutic procedures are performed as part of routine clinical care using commercially available CE-marked cardiac implantable electronic devices according to their approved indications and current international guideline recommendations. The study does not introduce experimental devices or procedures beyond standard clinical practice but prospectively evaluates the clinical performance of an individualized physiological CRT algorithm.

The comprehensive study database integrates demographic, clinical, electrocardiographic, echocardiographic, cardiac magnetic resonance imaging, procedural, device-derived, and long-term follow-up data. This integrated approach enables detailed evaluation of the mechanisms underlying CRT response and supports the development of patient-specific resynchronization strategies.

Expected Clinical Significance

The RESYNC-PACE study is expected to generate real-world evidence regarding the effectiveness of conduction system pacing-guided CRT strategies and individualized resynchronization algorithms. The findings may improve patient selection, optimize implantation strategies for different conduction disorders, and contribute to the growing evidence supporting physiologic cardiac resynchronization therapy in patients with heart failure.

연구 유형

관찰

등록 (추정된)

50

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

  • 이름: Peter Ezer MD PhD, assistant professor
  • 전화번호: +36305468840
  • 이메일: ezerpeti@gmail.com

연구 장소

    • Baranya
      • Pécs, Baranya, 헝가리, 7621
        • Heart Institute , University of Pécs

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

아니

샘플링 방법

비확률 샘플

연구 인구

The study population consists of adult patients with heart failure with reduced ejection fraction (HFrEF) who are treated at the University of Pécs Clinical Centre Heart Institute and meet contemporary guideline indications for cardiac resynchronization therapy (CRT). Eligible participants have symptomatic heart failure despite guideline-directed medical therapy, left ventricular systolic dysfunction, and evidence of electrical dyssynchrony manifested by left bundle branch block (LBBB) or intraventricular conduction delay (IVCD). The prospective cohort includes patients undergoing conduction system pacing-based CRT as part of routine clinical care, while the historical control cohort includes patients previously treated with conventional biventricular CRT at the same institution. The study population represents a real-world heart failure population routinely referred for CRT implantation in tertiary cardiovascular care.

설명

Inclusion Criteria:

  • Age ≥18 years.
  • Symptomatic heart failure despite guideline-directed medical therapy.
  • Left ventricular ejection fraction (LVEF) ≤40%.
  • Indication for cardiac resynchronization therapy according to contemporary ESC guideline recommendations.
  • QRS duration ≥150 ms with either:

Left bundle branch block (LBBB), or Intraventricular conduction delay (IVCD).

  • Planned implantation of a CRT system
  • Ability to provide written informed consent
  • Expected survival greater than 24 months.

Exclusion Criteria:

  • Age <18 years and Age 100 < years
  • Pregnancy or breastfeeding.
  • Inability or unwillingness to provide informed consent.
  • Life expectancy <12 months due to non-cardiac comorbidities.
  • Active systemic infection or infection involving a cardiac implantable electronic device.
  • Reversible causes of heart failure expected to improve without CRT.
  • Participation in another interventional clinical trial that may affect study outcomes.
  • Inability to comply with follow-up requirements.
  • Missing essential baseline or follow-up data (retrospective cohort).
  • Any condition that, in the opinion of the investigators, would make participation inappropriate or interfere with study assessments.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
개입 / 치료
Left bundle branch block patients

LBBB Cohort (qLV-guided Cardiac Resynchronization Therapy)

Patients in this cohort have symptomatic heart failure with reduced left ventricular ejection fraction and complete left bundle branch block (LBBB) according to contemporary guideline criteria. Cardiac resynchronization therapy is performed using a personalized implantation strategy guided by the qLV ratio, defined as the interval between QRS onset and local left ventricular activation divided by the intrinsic QRS duration. The left ventricular lead is positioned at the site with the longest achievable electrical delay to maximize resynchronization benefit. Patients receive either conventional biventricular CRT or LOT- CRT according to clinical decision-making and anatomical feasibility. The cohort is followed longitudinally to evaluate the relationship between qLV-guided lead placement, electrical resynchronization, reverse ventricular remodeling, heart failure hospitalization, and all-cause mortality.

Conduction System Pacing-Guided Cardiac Resynchronization Therapy is an individualized resynchronization strategy used in patients with heart failure, reduced left ventricular ejection fraction, and electrical dyssynchrony. The intervention is based on direct recruitment of the native cardiac conduction system through left bundle branch area pacing (LBBAP). During implantation, electrical resynchronization is assessed using electrocardiographic and device-derived parameters. In patients with intraventricular conduction delay or incomplete electrical correction, additional left ventricular pacing may be provided using a coronary sinus lead, resulting in Left Bundle Branch Area Pacing Optimized Cardiac Resynchronization Therapy (LOT-CRT). The intervention aims to achieve more physiological ventricular activation than conventional biventricular pacing, improve electrical synchrony, promote reverse ventricular remodeling, and reduce heart failure-related adverse events.
다른 이름들:
  • Cardiac resynchronization therapy using left bundle branch area pacing with or without LV lead optimization.
  • Cardiac resynchronization guided by conduction system pacing to improve ventricular synchrony.
Intraventricular conduction delay patients

IVCD Cohort (Conduction System Pacing-Guided Resynchronization Strategy)

Patients in this cohort have symptomatic heart failure with reduced left ventricular ejection fraction and intraventricular conduction delay (IVCD) without typical left bundle branch block morphology. The resynchronization strategy is guided by the degree of electrical correction achieved with conduction system pacing. During implantation, left bundle branch area pacing (LBBAP) is attempted and paced QRS duration is assessed. If conduction system pacing alone results in a paced QRS duration greater than 130 ms, a Left Bundle Branch Area Pacing Optimized Cardiac Resynchronization Therapy (LOT-CRT) system is implanted by adding a left ventricular lead to further improve ventricular synchrony. The cohort is followed longitudinally to evaluate the association between electrical resynchronization, reverse ventricular remodeling, heart failure hospitalization, and all-cause mortality.

Conduction System Pacing-Guided Cardiac Resynchronization Therapy is an individualized resynchronization strategy used in patients with heart failure, reduced left ventricular ejection fraction, and electrical dyssynchrony. The intervention is based on direct recruitment of the native cardiac conduction system through left bundle branch area pacing (LBBAP). During implantation, electrical resynchronization is assessed using electrocardiographic and device-derived parameters. In patients with intraventricular conduction delay or incomplete electrical correction, additional left ventricular pacing may be provided using a coronary sinus lead, resulting in Left Bundle Branch Area Pacing Optimized Cardiac Resynchronization Therapy (LOT-CRT). The intervention aims to achieve more physiological ventricular activation than conventional biventricular pacing, improve electrical synchrony, promote reverse ventricular remodeling, and reduce heart failure-related adverse events.
다른 이름들:
  • Cardiac resynchronization therapy using left bundle branch area pacing with or without LV lead optimization.
  • Cardiac resynchronization guided by conduction system pacing to improve ventricular synchrony.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Composite of All-Cause Mortality and Heart Failure Hospitalization
기간: 24 months
Time to first occurrence of the composite endpoint of all-cause mortality or hospitalization due to worsening heart failure during the 24-month follow-up period.
24 months

2차 결과 측정

결과 측정
측정값 설명
기간
Change in Left Ventricular Ejection Fraction (LVEF)
기간: Baseline to 24 months

Change in left ventricular ejection fraction measured by transthoracic echocardiography between baseline and 24-month follow-up.

Ejection fraction is measured in percentage (%). Improvement in ejection fraction is detected as increase in percentage-value.

Baseline to 24 months
Change in Left Ventricular End-Systolic Volume ( LV ESV)
기간: Baseline to 24 months

Change in left ventricular end-systolic volumen measured by echocardiography between baseline and 24-month follow-up.

Left ventricular end-systolic volume in measured in mililiters ( ml) , decrease in LV ESV is a sign of clinical response on therapy.

Baseline to 24 months
Change in paced QRS Duration
기간: Baseline to 24 months

Reduction in QRS duration following cardiac resynchronization therapy compared with baseline electrocardiographic measurements.

Paced QRS duration is measured in miliseconds (ms). Decrease in paced QRS duration compared to preoperative QRS duration is marked as a good signal in cardiac resynchronization therapy.

Baseline to 24 months
New York Heart Association Heart Failure Functional Status
기간: Baseline to 24 months

Change in New York Heart Association (NYHA) functional class from baseline to follow-up. Stage I-IV.

NYHA improvement is detected as decrease in NYHA stage grade.

Baseline to 24 months

기타 결과 측정

결과 측정
측정값 설명
기간
Device-Related and Procedure-Related Complications
기간: 24 months
Incidence of device-related and procedure-related adverse events, including lead dislodgement, infection, pneumothorax, pocket hematoma, and system revision.
24 months

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 6월 29일

기본 완료 (추정된)

2030년 6월 29일

연구 완료 (추정된)

2031년 6월 29일

연구 등록 날짜

최초 제출

2026년 6월 28일

QC 기준을 충족하는 최초 제출

2026년 6월 28일

처음 게시됨 (실제)

2026년 7월 6일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 7월 10일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 7월 8일

마지막으로 확인됨

2026년 7월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • FF107 RESYNC-PACE ver1.0
  • Biotronik Research Grant FF107 (기타 보조금/기금 번호: BIOTRONIK SE & Co. KG Woermannkehre 1 12359 Berlin)

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

IPD 계획 설명

ndividual participant data will be shared only in a de-identified form and in accordance with applicable data protection regulations, institutional policies, and informed consent provisions. Data sharing may be limited where participant privacy, ethical considerations, or legal requirements prevent full disclosure of individual-level data.

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

예

미국에서 제조되어 미국에서 수출되는 제품

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다