이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Bronchoscopic Versus Airway Exchange Catheter-Guided Endotracheal Tube Exchange (Bronchex)

2026년 7월 10일 업데이트: Léo Franchetti

Bronchoscopic Endotracheal Tube Exchange as an Alternative to Airway Exchange Catheter-Guided Tube Exchange: A Prospective Study

This prospective experimental study compares two methods for replacing an endotracheal tube in Thiel-embalmed body donors. The conventional method uses an airway exchange catheter based on the Seldinger technique, whereas the investigational method uses a flexible bronchoscope to provide direct visual guidance throughout the exchange.

The primary outcome is the duration of interrupted ventilation, measured from cessation of ventilation until ventilation is resumed through a correctly positioned replacement tube. Secondary outcomes include unsuccessful tube exchange requiring complete reintubation, duration of individual procedural steps, procedures lasting more than 60 seconds, use of additional rescue equipment, and unforeseen technical difficulties.

Both techniques will be performed in two Thiel-embalmed donated human bodies using an alternating sequence. Four experienced physicians will perform 40 tube exchanges per technique, resulting in a total of 80 procedures.

연구 개요

상세 설명

Endotracheal tube exchange may be required because of cuff failure, inappropriate tube size, tube damage, luminal obstruction, or the need for a planned intervention. During conventional tube exchange over an airway exchange catheter, continuous visualization of the subglottic airway and trachea is not possible. Consequently, advancement of the replacement tube may fail or may result in airway injury.

The bronchoscopic tube-exchange technique is intended to provide continuous visual control throughout the procedure and immediate confirmation of the replacement tube position.

The study will be conducted using two human bodies donated for medical education and research and preserved using the Thiel embalming method. Before each experimental series, the donated body will be intubated with a 7.5-mm endotracheal tube, and tracheobronchial secretions will be suctioned.

Two experienced physicians in intensive care medicine and anesthesiology will perform the conventional airway exchange catheter-guided technique, and two experienced pulmonologists will perform the bronchoscopic technique. To minimize order, learning, and tissue-wear effects, the techniques will be alternated. The starting technique will differ between the two body donors.

Each physician will perform 10 tube exchanges per body donor using the assigned technique, resulting in 20 procedures per physician, 40 procedures per technique, and 80 procedures overall.

Procedure timing will be based on predefined start and end points. The primary interval begins when ventilation is interrupted and ends when ventilation is resumed through the correctly positioned replacement tube. A trained observer will record procedural times, individual procedural steps, technical difficulties, use of additional equipment, and unsuccessful exchanges using a standardized source document.

Where feasible, video or photographic documentation may be used to verify procedure timing and technical events. The face will remain covered to prevent identification of the body donor.

Continuous outcomes will be analyzed using the paired Wilcoxon signed-rank test. Paired dichotomous outcomes will be analyzed using the McNemar test. Descriptive statistics will include medians, interquartile ranges, and ranges.

연구 유형

중재적

등록 (추정된)

2

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 연락처 백업

연구 장소

      • Basel, 스위스
        • 모병
        • Unversity Hospital of Basel
        • 연락하다:
          • Léo Franchetti, MD

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

아니

설명

Inclusion Criteria:

  • Human body donor preserved using the Thiel embalming method.
  • Intact trachea without relevant postmortem or preparation-related lesions.
  • Documented consent for scientific use of the body and confirmation of anatomical suitability by the Institute of Anatomy.
  • Sufficient mobility of the neck, jaw, and laryngeal region to permit realistic tube-exchange maneuvers.

Exclusion Criteria:

  • Tumor or stenosis involving the larynx, trachea, or central airways.
  • Previous surgery or radiotherapy involving the larynx or oral cavity.
  • Previous pneumonectomy.
  • Previous tracheotomy or laryngectomy.
  • Inability to achieve safe or standardized positioning of the cadaver.
  • Incomplete consent documentation or unclear provenance.
  • Preservation using a fixation method other than the Thiel method.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 다른
  • 할당: 무작위화되지 않음
  • 중재 모델: 순차적 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
활성 비교기: Airway Exchange Catheter
The body donors will undergo a tube exchange with the conventional airway exchange catheter-guided technique
The existing tube fixation is released. A Cook airway exchange catheter is advanced through the in-situ endotracheal tube into the tracheobronchial tree. Ventilation is interrupted, the cuff is deflated, and the old tube is removed over the catheter. A new endotracheal tube is advanced over the catheter, the catheter is removed, the cuff is inflated, ventilation is resumed, and tube position is verified by lung auscultation.
다른 이름들:
  • Cook Catheter Tube Exchange
실험적: Bronchoscopic tube exchange
The body donors will undergo a tube exchange with the bronchoscopic tube-exchange technique
The replacement tube is preloaded onto a therapeutic flexible bronchoscope. The bronchoscope is advanced alongside the in-situ tube through the larynx into the trachea, and proximal tracheal secretions are suctioned. Ventilation is interrupted and the old tube is removed. The replacement tube is advanced over the bronchoscope into the trachea under direct visual control. The bronchoscope is removed, the cuff is inflated, and ventilation is resumed.
다른 이름들:
  • Bronchoscopic tube exchange

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Ventilation interruption time during endotracheal tube exchange
기간: During each tube-exchange procedure, from ventilation interruption to resumption (expected duration less than 5 minutes).
Time in seconds from interruption of ventilation until ventilation is resumed through the correctly positioned replacement tube
During each tube-exchange procedure, from ventilation interruption to resumption (expected duration less than 5 minutes).

2차 결과 측정

결과 측정
기간
Unsuccessful tube exchange requiring complete reintubation - number and proportion of exchanges in which the assigned technique is abandoned and full reintubation is required.
기간: Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Duration of individual procedural steps - time in seconds for predefined components, including preparation and tube advancement.
기간: Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Tube exchanges lasting more than 60 seconds - number and proportion of procedures with ventilation interruption exceeding 60 seconds.
기간: Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Use of additional rescue equipment - number and proportion of exchanges requiring an additional device, such as a laryngoscope.
기간: Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Unforeseen technical difficulties - type and frequency of technical problems not predefined in the protocol.
기간: Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).
Assessed during each tube-exchange procedure (approximately 5 minutes per procedure).

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 7월 10일

기본 완료 (추정된)

2026년 7월 10일

연구 완료 (추정된)

2026년 7월 10일

연구 등록 날짜

최초 제출

2026년 7월 10일

QC 기준을 충족하는 최초 제출

2026년 7월 10일

처음 게시됨 (실제)

2026년 7월 15일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 7월 15일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 7월 10일

마지막으로 확인됨

2026년 7월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다