Automatic Prosthetic Foot Stiffness Modulation to Improve Balance in the Real World
Automatic Activity-Dependent and Phase-Varying Prosthetic Foot Stiffness Modulation to Improve Balance Control in Individuals With Lower-Limb Amputations in the Real World
The goal of this clinical trial is to determine if automatic stiffness modulation improves balance control in ambulatory individuals with below-knee amputations in real-world conditions. The main question this clinical trial will answer is:
• Can a user-specific automatic stiffness prosthesis improve balance control compared to user's fixed stiffness prosthesis that was clinically prescribed?
Participants will perform free-ranging ambulatory activities outside the laboratory that include nine ambulatory activities of daily living (walking at different speeds, turning, ramp ascent/descent, while carrying a load, and while walking on uneven terrain) while wearing, in random order, 1) a fixed stiffness prosthesis that was clinically prescribed and 2) an automatic stiffness prosthesis that uses an open source ankle configured to implement a user- and activity-specific automatic stiffness modulation control scheme intended to improve balance control.
연구 개요
상태
정황
상세 설명
Individuals with lower limb amputations are at higher risk of falling compared to able-bodied and other clinical populations and are more likely to sustain life-altering injuries. The higher fall risk is primarily due to the loss of muscles crossing the ankle, which are critical to maintaining balance control. Prosthetic devices are designed to provide appropriate stiffness for needed stability and support. While research has shown the optimal stiffness to maintain balance varies across ambulatory activities (e.g., straight walking versus turning), most clinically prescribed prosthetic devices are passive and only provide a fixed stiffness level. The one commercially available, powered prosthetic ankle-foot, has not been shown to restore balance control. Thus, a prosthetic device that actively adjusts ankle stiffness across different ambulatory activities is critically needed to advance the field and improve balance control for those with lower-limb amputations. The goal of this clinical trial is to identify prosthesis stiffness that optimizes balance control in individuals with below knee amputations as they perform typical ambulatory activities of daily living. By matching the ankle stiffness to the task requirements, the investigators believe balance control will significantly improve and fall risk will decrease for those with lower-limb amputations.
Each participant will be fit with a novel prosthesis that includes a low-profile prosthetic foot whose stiffness category will be determined by their body weight and activity level (standard clinical practice), a prosthetic foot whose stiffness category is two categories stiffer, and another whose stiffness is two categories less stiff. Participants will continue to use their existing prosthetic socket and suspension system, but their pylon length will be adjusted as needed. While wearing the different study prostheses in randomized order, nine ambulatory activities will be performed in a motion capture laboratory.
- Walking on level ground at self-selected speed.
- Walking on level ground at 15% slower than self-selected speed.
- Walking on level ground at 15% faster than self-selected speed.
- Walking up an 8% slope at self-selected speed.
- Walking down an 8% slope at self-selected speed.
- Walking on level ground at self-selected speed while carrying a 5 kg load in one hand on their prosthetic side.
- Walking on level but uneven terrain at self-selected speed.
- Walking around 2-meter diameter circle at self-selected speed with the prosthetic side on the inside of the circle.
- Walking around 2-meter diameter circle at self-selected speed with the prosthetic side on the outside of the circle.
Ambulatory activities 1 through 6 will be performed on an instrumented treadmill. The load to be carried in activity 6 will be configured as a grocery bag with handles. Activity 7 will be performed on a rocky terrain treadmill. Activities 8 and 9 will be performed overground across five force plates embedded in the laboratory floor while following the outline of a 2-meter diameter circle. Rest breaks during all activities will be provided as needed.
The data from this experiment will be used to calculate the peak-to-peak range of the frontal plane whole-body angular momentum (a measure of balance control). The investigators will use these calculations to determine a user- and activity-specific automatic stiffness modulation control scheme intended to improve balance control.
Each participant will then be randomized to wear their fixed stiffness prosthesis or the automatic stiffness prosthesis. Subjects will be fit with the IMU sensors on their ankles, wrists, and upper torso. The automatic stiffness prosthesis will be programmed to emulate the user-specific and activity-specific automatic stiffness modulation control scheme. Subjects will be provided at least 10 minutes to walk about the laboratory to learn how the study prosthesis performs. Subjects, wearing the study prosthesis (fixed or automatic stiffness), will then walk a defined course about the hospital facility (both indoors and outdoors) in which each of the laboratory-based ambulatory activities will be represented. A study investigator will accompany the subject at a following distance of ~5 meters while video recording their gait. After completing the defined course, the subject will return to the laboratory where they will complete the Prosthetic Limb Users Survey of Mobility and the Activities-Specific Balance Confidence Scale questionnaires to assess their perceived functional mobility and balance confidence. The subject will then don the other study prosthesis (fixed or automatic stiffness) and then repeat the walk about the defined course and complete the two questionnaires a second time.
The results of this experiment will determine if automatic stiffness modulation improves the balance control of those with lower-limb amputation as they perform typical ambulatory activities of daily living using both biomechanical analyses and self-report assessments of perceived functional mobility and balance confidence.
The investigators hypothesize that the automatic stiffness prosthesis will provide improved balance control in real-world environments compared to the user's fixed stiffness prosthesis that was clinically prescribed. The investigators further hypothesize that the Prosthetic Limb Users Survey of Mobility score reported after wearing the automatic stiffness prosthesis will be greater than the score reported after wearing the fixed stiffness prosthesis, and the Activities-Specific Balance Confidence Scale score reported after wearing the automatic stiffness prosthesis will be greater than the score reported after wearing the fixed stiffness prosthesis.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Washington
-
Seattle, Washington, 미국, 98108
- VA Puget Sound Healthcare System
-
수석 연구원:
- Glenn K Klute, PhD
-
연락하다:
- Glenn K Klute, PhD
- 전화번호: 206.277.6792
- 이메일: Glenn.Klute@va.gov
-
연락하다:
- Elise Campbell
- 전화번호: 206.277.6792
- 이메일: Elise.Campbell@va.gov
-
수석 연구원:
- Richard R Neptune, PhD
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Unilateral transtibial (below-knee) amputation
- Been fit with a prosthesis and used it for at least 6 months
- Wear the prosthesis for 4 or more hours on average per day
- Be at least one-year post-amputation
- Able to walk on a treadmill
Exclusion Criteria:
- Presence of disorder, pain, or injury other than amputation that interferes with gait
- Current skin irritation or injury on residual limb
- Use of an assistive device for walking (cane, walker, etc.)
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 크로스오버 할당
- 마스킹: 더블
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Fixed stiffness prosthesis then automatic stiffness prosthesis
A within-subject crossover experiment will be conducted to determine if differences in balance control (peak-to-peak range of frontal plane whole body angular momentum) exist between two study prostheses. The two study prostheses include (1) the participant's fixed stiffness prosthesis and (2) a novel, automatic stiffness prosthesis. The order in which participants wore the study prostheses was randomized. The study will be conducted over 2 weeks. All participants will walk a defined course (both indoors and outdoors) about a hospital facility. Participants in this group will wear their fixed stiffness prosthesis first and then the automatic stiffness prosthesis. |
The participant's clinically prescribed prosthesis whose stiffness category is determined by the person's body weight and activity level (standard clinical practice).
A novel prosthesis whose user-specific and activity-specific stiffness profile is automatically modulated based on their ambulatory activity.
|
|
실험적: Automatic stiffness prosthesis then fixed stiffness prosthesis
A within-subject crossover experiment will be conducted to determine if differences in balance control (peak-to-peak range of frontal plane whole body angular momentum) exist between two study prostheses. The two study prostheses include (1) the participant's fixed stiffness prosthesis and (2) a novel, automatic stiffness prosthesis. The order in which participants wore the study prostheses was randomized. The study will be conducted over 2 weeks. All participants will walk a defined course (both indoors and outdoors) about a hospital facility. Participants in this group will wear the automatic stiffness prosthesis and then their fixed stiffness prosthesis. |
The participant's clinically prescribed prosthesis whose stiffness category is determined by the person's body weight and activity level (standard clinical practice).
A novel prosthesis whose user-specific and activity-specific stiffness profile is automatically modulated based on their ambulatory activity.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
정면 평면 전신 각운동량의 피크 간 범위
기간: 연구 방문 중(약 3시간)
|
전두면 전신 각운동량은 외부 힘이나 토크가 없을 때 전두면에서 사람이 회전하는 정도를 측정한 것입니다.
피크 대 피크 범위는 이 측정항목이 얼마나 변하는지를 정량화하며 개인의 균형을 설명하는 데 사용됩니다.
|
연구 방문 중(약 3시간)
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Prosthetic Limb Users Survey of Mobility
기간: During study visit (approximately 3 hours)
|
The Prosthetic Limb Users Survey of Mobility is a self-report instrument designed to measure the mobility of adults with lower limb amputations, utilizing a set of calibrated questions to assess perceived mobility in various activities.
The Prosthetic Limb Users Survey of Mobility has been recommended by the National Institute of Child Health and Human Development as a core Common Data Element for lower-limb loss research as outcome measures to assess mobility.
|
During study visit (approximately 3 hours)
|
|
Activities-Specific Balance Confidence Scale
기간: During study visit (approximately 3 hours)
|
The Activities-Specific Balance Confidence Scale is a 16-item self-report questionnaire that measures an individual's confidence in performing daily activities without losing balance or feeling unsteady.
It is widely used to identify individuals at risk of falls and to guide interventions aimed at improving balance and mobility.
The Activities-Specific Balance Confidence Scale has been recommended by National Institute of Child Health and Human Development as a core Common Data Element for lower-limb loss research as an outcome measure to assess balance.
|
During study visit (approximately 3 hours)
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
IPD 공유 기간
IPD 공유 액세스 기준
IPD 공유 지원 정보 유형
- 연구_프로토콜
- ICF
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
미국에서 제조되어 미국에서 수출되는 제품
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .