- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07791433
Automatic Prosthetic Foot Stiffness Modulation to Improve Balance in the Real World
Automatic Activity-Dependent and Phase-Varying Prosthetic Foot Stiffness Modulation to Improve Balance Control in Individuals With Lower-Limb Amputations in the Real World
The goal of this clinical trial is to determine if automatic stiffness modulation improves balance control in ambulatory individuals with below-knee amputations in real-world conditions. The main question this clinical trial will answer is:
• Can a user-specific automatic stiffness prosthesis improve balance control compared to user's fixed stiffness prosthesis that was clinically prescribed?
Participants will perform free-ranging ambulatory activities outside the laboratory that include nine ambulatory activities of daily living (walking at different speeds, turning, ramp ascent/descent, while carrying a load, and while walking on uneven terrain) while wearing, in random order, 1) a fixed stiffness prosthesis that was clinically prescribed and 2) an automatic stiffness prosthesis that uses an open source ankle configured to implement a user- and activity-specific automatic stiffness modulation control scheme intended to improve balance control.
Visão geral do estudo
Status
Intervenção / Tratamento
Descrição detalhada
Individuals with lower limb amputations are at higher risk of falling compared to able-bodied and other clinical populations and are more likely to sustain life-altering injuries. The higher fall risk is primarily due to the loss of muscles crossing the ankle, which are critical to maintaining balance control. Prosthetic devices are designed to provide appropriate stiffness for needed stability and support. While research has shown the optimal stiffness to maintain balance varies across ambulatory activities (e.g., straight walking versus turning), most clinically prescribed prosthetic devices are passive and only provide a fixed stiffness level. The one commercially available, powered prosthetic ankle-foot, has not been shown to restore balance control. Thus, a prosthetic device that actively adjusts ankle stiffness across different ambulatory activities is critically needed to advance the field and improve balance control for those with lower-limb amputations. The goal of this clinical trial is to identify prosthesis stiffness that optimizes balance control in individuals with below knee amputations as they perform typical ambulatory activities of daily living. By matching the ankle stiffness to the task requirements, the investigators believe balance control will significantly improve and fall risk will decrease for those with lower-limb amputations.
Each participant will be fit with a novel prosthesis that includes a low-profile prosthetic foot whose stiffness category will be determined by their body weight and activity level (standard clinical practice), a prosthetic foot whose stiffness category is two categories stiffer, and another whose stiffness is two categories less stiff. Participants will continue to use their existing prosthetic socket and suspension system, but their pylon length will be adjusted as needed. While wearing the different study prostheses in randomized order, nine ambulatory activities will be performed in a motion capture laboratory.
- Walking on level ground at self-selected speed.
- Walking on level ground at 15% slower than self-selected speed.
- Walking on level ground at 15% faster than self-selected speed.
- Walking up an 8% slope at self-selected speed.
- Walking down an 8% slope at self-selected speed.
- Walking on level ground at self-selected speed while carrying a 5 kg load in one hand on their prosthetic side.
- Walking on level but uneven terrain at self-selected speed.
- Walking around 2-meter diameter circle at self-selected speed with the prosthetic side on the inside of the circle.
- Walking around 2-meter diameter circle at self-selected speed with the prosthetic side on the outside of the circle.
Ambulatory activities 1 through 6 will be performed on an instrumented treadmill. The load to be carried in activity 6 will be configured as a grocery bag with handles. Activity 7 will be performed on a rocky terrain treadmill. Activities 8 and 9 will be performed overground across five force plates embedded in the laboratory floor while following the outline of a 2-meter diameter circle. Rest breaks during all activities will be provided as needed.
The data from this experiment will be used to calculate the peak-to-peak range of the frontal plane whole-body angular momentum (a measure of balance control). The investigators will use these calculations to determine a user- and activity-specific automatic stiffness modulation control scheme intended to improve balance control.
Each participant will then be randomized to wear their fixed stiffness prosthesis or the automatic stiffness prosthesis. Subjects will be fit with the IMU sensors on their ankles, wrists, and upper torso. The automatic stiffness prosthesis will be programmed to emulate the user-specific and activity-specific automatic stiffness modulation control scheme. Subjects will be provided at least 10 minutes to walk about the laboratory to learn how the study prosthesis performs. Subjects, wearing the study prosthesis (fixed or automatic stiffness), will then walk a defined course about the hospital facility (both indoors and outdoors) in which each of the laboratory-based ambulatory activities will be represented. A study investigator will accompany the subject at a following distance of ~5 meters while video recording their gait. After completing the defined course, the subject will return to the laboratory where they will complete the Prosthetic Limb Users Survey of Mobility and the Activities-Specific Balance Confidence Scale questionnaires to assess their perceived functional mobility and balance confidence. The subject will then don the other study prosthesis (fixed or automatic stiffness) and then repeat the walk about the defined course and complete the two questionnaires a second time.
The results of this experiment will determine if automatic stiffness modulation improves the balance control of those with lower-limb amputation as they perform typical ambulatory activities of daily living using both biomechanical analyses and self-report assessments of perceived functional mobility and balance confidence.
The investigators hypothesize that the automatic stiffness prosthesis will provide improved balance control in real-world environments compared to the user's fixed stiffness prosthesis that was clinically prescribed. The investigators further hypothesize that the Prosthetic Limb Users Survey of Mobility score reported after wearing the automatic stiffness prosthesis will be greater than the score reported after wearing the fixed stiffness prosthesis, and the Activities-Specific Balance Confidence Scale score reported after wearing the automatic stiffness prosthesis will be greater than the score reported after wearing the fixed stiffness prosthesis.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Washington
-
Seattle, Washington, Estados Unidos, 98108
- VA Puget Sound Healthcare System
-
Investigador principal:
- Glenn K Klute, PhD
-
Contato:
- Glenn K Klute, PhD
- Número de telefone: 206.277.6792
- E-mail: Glenn.Klute@va.gov
-
Contato:
- Elise Campbell
- Número de telefone: 206.277.6792
- E-mail: Elise.Campbell@va.gov
-
Investigador principal:
- Richard R Neptune, PhD
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Unilateral transtibial (below-knee) amputation
- Been fit with a prosthesis and used it for at least 6 months
- Wear the prosthesis for 4 or more hours on average per day
- Be at least one-year post-amputation
- Able to walk on a treadmill
Exclusion Criteria:
- Presence of disorder, pain, or injury other than amputation that interferes with gait
- Current skin irritation or injury on residual limb
- Use of an assistive device for walking (cane, walker, etc.)
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Fixed stiffness prosthesis then automatic stiffness prosthesis
A within-subject crossover experiment will be conducted to determine if differences in balance control (peak-to-peak range of frontal plane whole body angular momentum) exist between two study prostheses. The two study prostheses include (1) the participant's fixed stiffness prosthesis and (2) a novel, automatic stiffness prosthesis. The order in which participants wore the study prostheses was randomized. The study will be conducted over 2 weeks. All participants will walk a defined course (both indoors and outdoors) about a hospital facility. Participants in this group will wear their fixed stiffness prosthesis first and then the automatic stiffness prosthesis. |
The participant's clinically prescribed prosthesis whose stiffness category is determined by the person's body weight and activity level (standard clinical practice).
A novel prosthesis whose user-specific and activity-specific stiffness profile is automatically modulated based on their ambulatory activity.
|
|
Experimental: Automatic stiffness prosthesis then fixed stiffness prosthesis
A within-subject crossover experiment will be conducted to determine if differences in balance control (peak-to-peak range of frontal plane whole body angular momentum) exist between two study prostheses. The two study prostheses include (1) the participant's fixed stiffness prosthesis and (2) a novel, automatic stiffness prosthesis. The order in which participants wore the study prostheses was randomized. The study will be conducted over 2 weeks. All participants will walk a defined course (both indoors and outdoors) about a hospital facility. Participants in this group will wear the automatic stiffness prosthesis and then their fixed stiffness prosthesis. |
The participant's clinically prescribed prosthesis whose stiffness category is determined by the person's body weight and activity level (standard clinical practice).
A novel prosthesis whose user-specific and activity-specific stiffness profile is automatically modulated based on their ambulatory activity.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Faixa pico a pico do momento angular de corpo inteiro no plano frontal
Prazo: Durante a visita de estudo (aproximadamente 3 horas)
|
O momento angular de corpo inteiro no plano frontal é uma medida da extensão em que uma pessoa irá girar no plano frontal na ausência de uma força ou torque externo.
A faixa pico a pico quantifica o quanto essa métrica varia e é usada para descrever o equilíbrio de uma pessoa.
|
Durante a visita de estudo (aproximadamente 3 horas)
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Prosthetic Limb Users Survey of Mobility
Prazo: During study visit (approximately 3 hours)
|
The Prosthetic Limb Users Survey of Mobility is a self-report instrument designed to measure the mobility of adults with lower limb amputations, utilizing a set of calibrated questions to assess perceived mobility in various activities.
The Prosthetic Limb Users Survey of Mobility has been recommended by the National Institute of Child Health and Human Development as a core Common Data Element for lower-limb loss research as outcome measures to assess mobility.
|
During study visit (approximately 3 hours)
|
|
Activities-Specific Balance Confidence Scale
Prazo: During study visit (approximately 3 hours)
|
The Activities-Specific Balance Confidence Scale is a 16-item self-report questionnaire that measures an individual's confidence in performing daily activities without losing balance or feeling unsteady.
It is widely used to identify individuals at risk of falls and to guide interventions aimed at improving balance and mobility.
The Activities-Specific Balance Confidence Scale has been recommended by National Institute of Child Health and Human Development as a core Common Data Element for lower-limb loss research as an outcome measure to assess balance.
|
During study visit (approximately 3 hours)
|
Colaboradores e Investigadores
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- 1817327-27
- 1R01HD111514-01A1 (Concessão/Contrato do NIH dos EUA)
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
Prazo de Compartilhamento de IPD
Critérios de acesso de compartilhamento IPD
Tipo de informação de suporte de compartilhamento de IPD
- PROTOCOLO DE ESTUDO
- CIF
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .