이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Comparative Study of the Tomey FT-1000, and Goldmann Applanation Tonometer (GAT)

2026년 9월 3일 업데이트: Tomey Corporation

This study is intended to evaluate the agreement between Intraocular pressure(IOP) measurements obtained with the FT-1000 non-contact tonometer and a GAT to confirm the feasibility of the measurement procedures.

This is a prospective comparative study that will be conducted at one clinical site in the United States. Subjects who sign an informed consent form and fulfill all inclusion and exclusion criteria will undergo FT-1000 measurements followed by Goldmann applanation tonometry during a single study visit.

The primary analysis will be performed using one preselected study eye from each subject. Measurements from the fellow eye, when available, may be summarized as exploratory analyses but will not contribute to the primary effectiveness analysis.

In general, descriptive statistics (n, mean, standard deviation, median, minimum and maximum) will be used to summarize continuous variables. Frequencies and percentages will be used to summarize categorical variables. The number of accepted scans and the total number of scans evaluated will be summarized by scan type, device, and subject population.

Agreement between the FT-1000 and the Goldmann applanation tonometer will be evaluated using the study eye measurements by calculating the mean difference, standard deviation (SD), 95% limits of agreement (LOA), Bland-Altman plots, Deming regression, and Pearson correlation coefficient.

Exploratory analyses may also be performed using fellow-eye measurements.

연구 개요

상태

아직 모집하지 않음

정황

연구 유형

관찰

등록 (추정된)

30

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

예

샘플링 방법

비확률 샘플

연구 인구

Low Intraocular pressure(IOP) (22 years old or older) Middle Intraocular pressure(IOP)(22 years old or older) High Intraocular pressure(IOP)(22 years old or older)

설명

Inclusion Criteria:

  1. Male or female subjects 22 years of age or older who have full legal capacity to volunteer on the date the informed consent is signed.
  2. Subjects who are able to understand and follow the study procedures and instructions provided by the clinical staff.
  3. Subjects who voluntarily provide written informed consent.
  4. Subjects who satisfy all study eligibility requirements and are able to undergo both FT-1000 and Goldmann applanation tonometry measurements during the study visit.

Exclusion Criteria:

  1. Subjects with only one functional eye.
  2. Subjects with poor or eccentric fixation in either eye.
  3. Subjects with a history of corneal surgery, including corneal laser or refractive surgery (e.g., LASIK).
  4. Subjects with corneal scarring, keratoconus, or any other clinically significant corneal pathology.
  5. Subjects with an active corneal or conjunctival infection or inflammation in either eye.
  6. Subjects with microphthalmos or buphthalmos.
  7. Subjects who are unable or unwilling to remove contact lenses before study measurements.
  8. Subjects with clinically significant dry eye disease that, in the investigator's opinion, may affect tonometry measurements.
  9. Subjects with blepharospasm (lid squeezing) or nystagmus that may interfere with accurate measurements.
  10. Subjects with abnormal central corneal thickness (CCT).
  11. Subjects with any condition or circumstance that, in the opinion of the investigator, could place the subject at significant risk, interfere with study participation, or confound interpretation of the study results.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
개입 / 치료
Low Intraocular pressure(IOP) Group: 7-16 mmHg
Group with IOP of 7-16 mmHg; 10 subjects.
Intraocular pressure measurement by non-contact tonometer and applanation tonometer.
Middle Intraocular pressure(IOP) Group: >16 to <23 mmHg
Group with IOP of >16 to <23 mmHg; 10 subjects.
Intraocular pressure measurement by non-contact tonometer and applanation tonometer.
High Intraocular pressure(IOP)Group: ≥23 mmHg
Group with IOP of ≥23 mmHg; 10 subjects.
Intraocular pressure measurement by non-contact tonometer and applanation tonometer.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Safety of the test devices
기간: Through study completion, approximately 3 days
Any adverse events observed or reported during the study visit will be assessed and documented.
Through study completion, approximately 3 days
Agreement of the Intraocular pressure (IOP) mmHg between the test devices and predicate device
기간: Through study completion, approximately 3 days

Agreement of the Intraocular pressure (IOP) mmHg between the FT-1000 and the Goldmann Applanation Tonometer(GAT) will be evaluated using the study eye measurements by calculating the mean difference, standard deviation (SD), 95% limits of agreement (LOA), Bland-Altman plots, Deming regression, and Pearson correlation coefficient.

Exploratory analyses may also be performed using fellow-eye measurements.

Through study completion, approximately 3 days

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 9월 24일

기본 완료 (추정된)

2026년 9월 28일

연구 완료 (추정된)

2026년 9월 28일

연구 등록 날짜

최초 제출

2026년 8월 31일

QC 기준을 충족하는 최초 제출

2026년 8월 31일

처음 게시됨 (실제)

2026년 9월 4일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 9월 9일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 9월 3일

마지막으로 확인됨

2026년 8월 1일

추가 정보

이 연구와 관련된 용어

추가 관련 MeSH 약관

기타 연구 ID 번호

  • TomeyFT-1000-001

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

예

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .